Tender For special repair To electrical installation Of Family Court Building & Hazat Building At Civil Court, Sahibgnaj.
Tender Value
16.12 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
3 days left
EMD
32500
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dumka → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special repair To electrical installation Of Family Court Building & Hazat Building At Civil Court, Sahibgnaj.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point, fan point, exahust fan point, call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit with piano type switch, phenolic laminated sheet, suitable size G.I / PVC box etc as reqd.(211+35) |
| 2 | a) Group - C |
| 3 | Wiring for light/ power plug with 2 x 4 sq mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 no 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as reqd. |
| 4 | Wiring for circuit submain wiring along with earth wire with the following size PVC insulated copper conductor, single core cable in surface / recessed PVC conduit etc as reqd. |
| 5 | a) 2 x 2.5 sq mm + 1 x 2.5 sq mm Earth wire (For light circuit) |
| 6 | b) 2 x 1.5 sq mm + 1 x 1.5 sq mm Earth wire (For TV board wiring.) |
| 7 | c) 2 x 2.5 sq mm + 1 x 2.5 sq mm Earth wire (For Computer Board wiring.) |
| 8 | d) 2 x 4.0 sq mm + 1 x 4.0 sq mm Earth wire (A.C. wiring direct from Busbar) |
| 9 | e) 2 x 4.0 sq mm + 1 x 4.0 sq mm Earth wire (For light & Comp Submain) (60x2) |
| 10 | f ) 2 x 6.0 sq mm + 1 x 6.0 sq mm earth wire (For Power submain) |
| 11 | g) 1 x 1.5 sq, mm. (For Inverter wiring.) |
| 12 | Supplying and fixing suitable size GI/PVC box of 75mm x 75 mm x 50mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch. connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 13 | Supplying and fixing suitable size GI/PVC box of 121 mm x 173mm x 48mm/(6\\" x 8\\") (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 & 15/16 amps socket outlet and 15/16 amps piano type switch. connection, painting etc. as required |
| 14 | S/F a compact unit made of 170mm x 146mm x 48 mm deep/6\\"x8\\" G.I./PVC box with suitable size of phenolic laminated sheet cover in front of fixed with 2 no. of 5/6 Amp, piano type one way switch and 2 no. 5/6 Amp, 3 Pin socket outlet Name as TV board. (TV board) |
| 15 | a) 5/6 Amp switch - 2 Nos @ 32.00 = 64.00 |
| 16 | b) 5/6 Amp socket - 2 Nos @ 43.00 = 86.00 |
| 17 | c) 7\\" x 4\\" PVC Board -1 Nos @ 124 = 124.00 |
| 18 | Total = 274 |
| 19 | S/F a compact unit made of 170mm x 146mm x 48 mm deep/8\\"x10\\" G.I./PVC box with suitable size of phenolic laminated sheet cover in front of fixed with 3 no. of 5/6 Amp, piano type one way switch and 3 no. 5/6 Amp, 3 Pin socket outlet and 1 No. 15/16 Amp, 6 pin S.S. Combined well connected with suitable wire, earthing etc as reqd. Name as computer board. |
| 20 | a) 5/6 Amp switch - 3 Nos @ 32.00 = 96.00 |
| 21 | b) 5/6 Amp socket -3 Nos @ 43.00 = 129.00 |
| 22 | c) 15/16 Amp, S.S. Combined = 1 Nos @ 112.00 = 112.00 |
| 23 | d) 8\\"x10\\" PVC Board -1 Nos @ 223 = 223.00 |
| 24 | Total = 560.00 |
| 25 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 27 | a) 2 way single door. |
| 28 | b) 4 way single door. |
| 29 | c) 8 way single door. (Hazat) |
| 30 | d) 6 way, single door. |
| 31 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, \\"B\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
| 32 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, \\"B\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
| 33 | a) 32 amp D.P. MCB |
| 34 | b) 63 amp D.P. MCB |
| 35 | S/F PVC/G.I box of following size on surface or in recess with suitable size of phenolic laminated sheet cover inforant including painting etc as reqd. |
| 36 | a) 72 mm x 146mm x 48mm deep/ (4\\" x 7\\") |
| 37 | b) 170 mm x 221 mm x 48 mm deep/(8\\"x10\\") |
| 38 | S/F 2 pin 5 Amp. Ceiling rose on the existing junction box etc |
| 39 | Supplying and fixing batten/ angle holder including connections etc as reqd. |
| 40 | Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connections etc. as required. |
| 41 | a) Electronic step fan regulator Delux. |
| 42 | Supplying and fixing Ding-Dong sound call bell single phase. 230 volt, complete as required |
| 43 | S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 44 | a) 20/22W LED Tube light |
| 45 | S/F 9/10 watt LED bulb |
| 46 | S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722 with all neccssary accessories as required |
| 47 | a) 15w LED round down light. |
| 48 | S.I.T.C. of following size ceilling fan 3 blades confirming to IS:374:2019 including wiring the down roadsof suitable length (up to 30cm) with 1.5 sq. mm. PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as regd. |
| 49 | a) 1200 mm (48\\") ceilling fan (26+6Hazat) |
| 50 | S/F 12\\" (300mm) metal exaust fan |
| 51 | S/F 16\\" (400 mm) Metal wall mounted fan. |
| 52 | S.I.T.C of following rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 53 | a) 90w L.E.D. Street light. |
| 54 | Supplying and laying of XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following size |
| 55 | a) 6 sq, mm. 2 core (For 10 LED Street light.) |
| 56 | b) 35 sq, mm. 3.5 core (From Pole to panel) |
| 57 | c) 35 sq, mm. 3.5 core (For Solar.) |
| 58 | d) 25 sq, mm. 3.5 core (From panel to Sub Panel.) |
| 59 | e) 10 sq, mm. 4 core (From pole to hazat building.) |
| 60 | Laying of one number PVC insulated PVC Sheathed XLPE power cable of 1.1 KV grade of size on wall surface as reqd. up to 35 sq, mm (clamp with 1 mm thik saddle) |
| 61 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation and refilling the trench etc as reqd. But excluding sand cushioning and protective covering. |
| 62 | 6 sq mm aluminium lugs |
| 63 | 10 sq mm aluminium lugs |
| 64 | 25 sq mm aluminium lugs |
| 65 | 35 sq mm aluminium lugs |
| 66 | Supplying and fixing cable junction box with 1 No. 6 Amp, S.P MCB make:- Sintex / Hensel or equivelant. |
| 67 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 68 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc, as required. |
| 69 | Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting/fixing/connection & transportation up to work site, labour charge etc all complete. (1 family court, 1 Hazat building) |
| 70 | 25-100 amps, MCCB 10 KA fixed thermal setting (Incoming) = 1 Nos. |
| 71 | LED Indecator lamp R / Y / B / G = 3 Nos. |
| 72 | 25mm x 5mm copper strips (1.15kg / mtr) = 5kg |
| 73 | Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting /fixing/connection & transportation up to work site, labour charge etc all complete. |
| 74 | 100 Amps, MCCB 10 KA fixed thermal setting (Outgoing) = 3 Nos. |
| 75 | 200 Amps, MCCB 35 KA fixed thermal setting (main line Incoming) = 1 Nos. |
| 76 | 160 Amps, MCCB 35 KA fixed thermal setting (Solar line Incoming) = 1 Nos. |
| 77 | 160 Amps, MCCB 35 KA Ajustable thermal setting (gen line Incoming) = 1 Nos. |
| 78 | 200 Amp, 4 Pole Changeover Switch = 2 Nos. |
| 79 | Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 = 2 Nos. |
| 80 | Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 = 2 Nos. |
| 81 | C.T. Coil of C.T. Ratio 300/5 = 6 Nos. |
| 82 | LED Indecator lamp R/Y/B/G = 6 Nos. |
| 83 | 25mm x 5mm copper strips (1.15kg / mtr) = 14kg |
| 84 | 50mm x 5mm copper strips (2.3kg / mtr) = 38Kg |
| 85 | Add Dismentle Charge @1% |
| 86 | Less Scrap @2% |
| 87 | CGST@9% |
| 88 | SGST@9% |
| 89 | Add labour cess @1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender