Tender For Restoration Of Rain Damages To Water Supply Scheme Dhand Khandaru In G.P Bhawla Tehsil Churah Distt.Chamba(Hp) Sh:- Repair Construction of Intake 1 No ,Rcc Storage Tank 10000 Litrs Cap. & Repair Of G.I Pipe 32 Mm Dia At Various Rds)
Tender Overview
Project Description
Tender for Restoration Of Rain Damages To Water Supply Scheme Dhand Khandaru In G.P Bhawla Tehsil Churah Distt.Chamba(Hp) Sh:- Repair Construction of Intake 1 No ,Rcc Storage Tank 10000 Litrs Cap. & Repair Of G.I Pipe 32 Mm Dia At Various Rds)
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in foundation, trenches etc. in all kinds of soil such as pick work, jumper work, blasting work in soft / hard rock, chiselling in soft / hard including wedging out of a rock where blasting is prohibited and stacking the excavated earth up to all lifts, stacking the excavated soil up to all lead clear from the edge of excavation and then returning the stacked soil in 15 centimeters layers when required in to plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as per direction and to the entire satisfation of Engineer- in- charge up to leads and lifts. |
| 2 | Providing and laying cement conrete 1 : 3 :6 . ( 1 cement : 3 sand and : 6 grade stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth upto all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge. |
| 3 | Providing and laying cement concrete 1 : 1½ : 3 mix. ( 1 cement : 1½ : sand : 3 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinfocement for reinforced concrete work in |
| 4 | (a) Foundation footings bases of columns and the like; and mass concreteas per direction and to the entire satisfaction of Engineer-in-Charge. |
| 5 | (b) Walls any thickness but not less than 0.1m thickness including attached pillaster buttresses, plinth and string courses from top of foundation upto two level all floor level as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 6 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering strutting and propping etc. with wooden batten and ballies, in all heights of propping and centring below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for insitu-reinforced concrete and plain concrete work in :- |
| 7 | In flat surfaces with steel plates such as soffits of suspended floors, roofs, landing and the like floor etc upto all thickness in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 8 | Vertical surfaces such as wall (any thickness) partitions and the like including attached pillasters, buttresses plinth and string courses and the like in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 9 | P/L cement concrete work 1:2:4(1cement:2sand:4graded stone aggregate 20mm nominal size)and curing complet excluding the cost of form work and reinforcemnet work,in suspended floor,roofs,landing and shelves and tdheir support Balconies,Beams,girders,bressumers and contilevers upto floor two level as per the direction and entire satisfaction of Engineer-in-Charge. |
| 10 | Providing mild steel/tor steel (reinforcement for RCC work) including bending,binding and placing in positioncomplete in all respect including all leads and lifts as per the direction and entire satisfaction of Engineer-in-Charge.(Steel will be issued free of cost.) |
| 11 | Laying, Jointing in trenches galvanized mild steel tubes including fittings complete for inlet outlet overflow & scour pipe with in all leads and lifts of the following nominal bores:. |
| 12 | 50 mm Dia |
| 13 | Providing & Fixing Stair case embaded in cement concrete |
| 14 | Providing & Fixing mainhole cover with frame (including locking arrangment |
| 15 | Providing & fixing of Gun metal full way wheel valve inlet outlet overflow & scour pipe as per the direction of Engineer-in-charge |
| 16 | 32mm dia |
| 17 | Laying, Jointing in trenches galvanized mild steel tubes including fittings complete (earth work in trenches to be measured and paid for separately) including complete fitting and as per the direction of the Engineer-in-charge with in all leads and lifts of the following nominal bores:. |
| 18 | 32 mm Dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender