Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 2 days TDR #56965191

Tender For Renovation & Retrofitting Of Battery Systems For Ht/Lt Panels At 20 Mgd Booster Pumping Station Okhla Water Works. Make: Mmax.

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Aug 2026
2 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation & Retrofitting Of Battery Systems For Ht/Lt Panels At 20 Mgd Booster Pumping Station Okhla Water Works. Make: Mmax.

BOQ

Name of Work:- Renovation & retrofitting of Battery Systems for HT/LT Panels at 20 MGD Booster Pumping Station Okhla Water Works. Make: MMAX.
Sl. No. Item Description
1S.No. SPECIFICATION OF FBCP 30VDC / 20 Amp 1ɸ FCBC FOR HT/LT PANEL1.Type FCBC, 2. Manufacturer Maha Mai Engineers, 3. Make “MMAX Power”,4. Nominal input voltage 1 PHASE 230V ±10%, 5. Frequency of input supply 50 Hz ±5%, 6. Nominal output voltage 30 V DC, 7. Output voltage variation ±0 .05V/cell at rectifier O/P, 8. Nominal output current 40A [20A Battery + 20A Load ], 9.DC O/P Voltage Settings Nominal DC Output Voltage : 30 V DC (12 Cells of 2 V, 200 Ah SMF VRLA Battery) Float Charging Voltage @ 27°C : 33.0 V DC (2.25 V/ Cell ±5%), Adjustable Boost Charging Voltage @ 27°C : 34.5 V DC (2.35 V/Cell ±5%), Adjustable Temperature Compensation: Automatic temperature compensation Output Voltage Regulation: Better than ±1% from no-load to full-load. 10. Ripple ≤ 5 % RMS, 11.Noise level < 65 DB, 12. Static stability INBUILT 13. Charging method Auto Boost & Float 14. Operational ambient temperature range 0⁰ C - 55⁰ C 15. Boost charging automatically and manually Both mode provided. 16. Rectifier Block Type Thyristor-Diode full bridge half controlled. 17. DC filter type LC, 18. Earthing From body. 19. Protection degree IP – 30, 20. Cooling method Natural & by Fan, 21.Structure steel CRCA, 22. Steel thickness 16 SWG as per IS, 23. Structure Paint Powder coating, 24. Paint Shade RAL-7035, 25..DC Volt Meter Type / Size /Range/Accuracy Class Analog /96 X 96 mm/0-50 A/1.5, 26. O/P Voltmeter Type / Size /Range/Accuracy Class Analog /96 X 96 mm/0-50 A/1.5, 27. O/P Ammeter Type / Size /Range/Accuracy Class Analog /96 X 96 mm/0-50 A/1.5, 28. Battery Charge/Discharge / Size /Range/Accuracy Class Analog /96 X 96 mm/0-50 A/1.5, 29. I/P breaker 32A DP MCB, 30. Battery breaker 63A DP MCB31 Load breaker 63A DP MCB, 31. Outgoing Feeders 16A DP MCB (6 Nos.), 32. Over Load protection Electronic, 33. Short circuit protection Electronic & MCB, 34. O/P Over voltage protection Electronic, 35. Rotary Switch 3 way 2 pole, 36. Potentiometer: Float /Boost/Voltage Adjust, 37. Rectifier transformer Make: MAHA MAI VA RATING 2200 VA WINDING Class F Copper Wire Limits of temperature rise over ambient of 50°C not more than 90⁰ C, 38. Filter Choke Make: MMAX POWER RATING 20A WINDING Class F Copper Wire Limits of temperature rise over ambient of 50°C not more than 90⁰ C, 39. Control & Electronics Wiring 1.5 sq. mm AC Power Wiring 2.5 sq. mm DC Power Wiring 2.5 sq. mm & 10 Sq mm, 40. Blocking Diode Provided, 41. Standards Applicable Relevant IS & IEC, 42. Indications MAINS ON MAINSA FAIL CHARGER ON CHARGER FAIL* Auto Mode, Float Mode, Boost Mode DC High Voltage Trip RECTIFIER FUSE FAIL FILTER FUSE FAIL DC OVER LOAD EARTH FAULT
2Renovation of Existing BCP for HT Panel. The work includes disconnection of cables from the Main HT Panel and BCP, termination of cables to the FBCP and HT/LT Panel using suitable thimbles and allied accessories. The work also includes necessary civil works., the system shall be tested and commissioned successfully under both no-load and full-load operating conditions.
3Packing and forwarding , Freight unloading Charges Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56965191
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 17-08-2026
Authority
Authority Name Delhi Jal Board
Work Description Tender for Renovation & Retrofitting Of Battery Systems For Ht/Lt Panels At 20 Mgd Booster Pumping Station Okhla Water Works. Make: Mmax.
Basic Detail
Tender No NIT NO. 06 (2026-27)/WW-III
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 11 Aug 2026
Submission Date 17 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 50000
Exemption Not Available
Document List
BOQ_395298.xls
e8801b54-f095-4f7c-8f8c-24b922130fcf.html
NIT06.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_395298.xls

html

e8801b54-f095-4f7c-8f8c-24b922130fcf.html

pdf

NIT06.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders