Housing Urban and Rular Development Local Bodies Closing in 2 days TDR #56964754

Tender For maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh: repair maintenance Of Aeration System In Water Body At Bhalswa Lake, And Annual, Repairing & Maintenance Of Pump Sets, Park & Lake Front Road Lighting, Panel Boa

Issued by Local Bodies · Delhi, Delhi
Tender Value
25.81 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
2 days left
EMD
51621
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh: repair maintenance Of Aeration System In Water Body At Bhalswa Lake, And Annual, Repairing & Maintenance Of Pump Sets, Park & Lake Front Road Lighting, Panel Board Accessories Etc. At Bhalswa Lake Park Of Hd-10 Under North Zone.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Aug-2026 Corrigendum Other 17-Aug-2026

BOQ

Name of Work:- M/o Completed Scheme under Nazul Account-II, Horticulture Zone.SH: RMO of Aeration System in Water Body at Bhalswa Lake, and Annual, Repairing & Maintenance of Pump Sets, Park & Lake Front Road Lighting, Panel Board Accessories etc. at Bhalswa Lake Park of HD-10 under North Zone.
Sl. No. Item Description
1Repair, Maintenance & Operation (RMO) of Water Body Floating Aeration System, and Annual Maintenance of Pump Sets, Lighting, Panel Accessories etc. as per attached Inventory and Terms & Conditions.
2Repairing and Rewinding of 3-Phase Open Well type Dewatering/Sewage Mono-Block Submersible Pump Set (5-7.5 HP) including dismantling, Lifting of Pump Set from Water Body, cartage (to & fro), reassembling after repair, Replacement of all damaged parts (bearing, bush, seals, etc.), electrical connections, testing, painting & making good for return to serviceability complete as required as per direction of Engineer-in-Charge.
3Repairing & Rewinding of Submersible Motors of following capacity including cartage (to & fro), dismantling, rewinding with Class-F copper wire, reassembling, supply & replacement of all damaged parts (mechanical seals, bearings, O-rings, cable gland, etc.), and making good for operation. Works also include Electrical connections, testing, painting, and complete as required for return to serviceability. Up to 2 Hp, 1-Ph/3-Ph Submersible Motors
43 Hp to 5 Hp, 3-Ph Submersible Motors
5Repairing of Submersible Pump Set of the following Stages & dia. including cartage (to & fro), dismantling, reassembling, supply & replacement/repairing of all damaged parts of Pump Set, and making good for operation i/c testing, painting etc. complete as required.4\\"dia. Submersible Pump Set up to all Stages
6Lifting Out of Sewage Submersible Pump Set from the Existing Bore well up to the required depth along with existing GI Pipes and accessories etc. including disconnecting of GI Pipe & Submersible Cable etc. complete as required.
7Lowering and Commissioning of Submersible Pump Set in the Existing Bore well up to the required depth along with Replaced (if required)/Existing GI Pipe & Submersible Cable etc., Clamping (at appropriate distance), Water Proof Jointing of Submersible Cable. Replacement of required nuts, bolts, washers and packing, nipple, reducer, connection, testing etc. complete as required.
8Supplying and Replacement of following size Double Flanged of \\"B\\" Class GI Pipe conforming to IS:1239 including welding and all fittings (elbows, tees, flanges, reducers/tapers), nuts, bolts, gaskets, painting and accessories etc. complete as required including rebate for dismantle material. 40 mm dia.
9Supplying & Replacement of PVC Insulated PVC Sheathed Copper Conductor Submersible Flat Cable ISI marked in Existing Metal/HDPE/PVC/Pipe/in Bore well/in Sump including Fixing the Cable to GI/HDPE Pipe with suitable Cable tags of following sizes etc. complete as required including rebate for dismantle material.3 Core 2.5 Sq mm Flat Cable
103 Core 6 Sq mm Flat Cable
11Supplying and Replacement of following Control Gear/accessories in the Existing Installation for Electric Panel Board/Feeder Pillar, Motor Starter complete in all respect including connections with appropriate size FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required including rebate for dismantle Fixture.6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity.
126 A to 32 A ratings, TP MCB, “C” curve, 10 KA breaking capacity.
1363 A, FP MCB, “C” curve, 10 KA breaking capacity
14100 A, 30 KA, 4-Pole MCCB
15250 A, 36 KA, 4-Pole MCCB
166 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity.
173-Phase DOL MK1 Starter suitable up to 7.5 HP Pump Set with Relay Range 13 to 22 Amp.
18Single Phase Submersible Pump Controller (MR-G2) up to 3 Hp with Relay Range 13 to 22 Amp, Start Capacitor 275 V, 50 Hz (200/250), Run Capacitor 440 V, 50 Hz MFD (2 x 50), Ammeter & Voltmeter.
193-Phase Submersible Pump Controller (MU-G7.5 DOL) with Single Phase Preventer up to 7.5 Hp Pump Set, Relay Range 13 to 21 Amp.
20Single Phasing Preventer (VSP2- Auto Reset, 40 Volts Unbalance) mounted on Panel Wall.
21Electronic/Analogue Timer of model FM1/Quartz Daily 110 VAC-240 VAC Base/DIN Mounting in the existing Panel.
223-Pole Power Contactor of AC3 Rating 32 Amp, MNX 32 type.
23Supplying and Replacement of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C) including rebate for dismantle Fixture.72 Watt
24Supplying and Replacement of Flood Light, Powder Coated Pressure Die Cast Aluminum body with built in or separate driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP-66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR-15, Lenses for Beam Angle 30°-120° as per the application and the project requirement, suitable tilt able Fitting, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C) including rebate for dismantle Fixture.100 Watt
25Supplying and Drawing of following sizes FRLS PVC Insulated Copper Conductor, Single Core Cable in the Existing Surface/Recess Steel/PVC Conduit as required including rebate for dismantle material.3C x 1.5 sq.mm
263C x 2.5 sq. mm
27Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required including rebate for dismantle material.2C x 16 sq. mm
284C x 25 sq. mm
29Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the Existing RCC/HUME/METAL Pipe as required.Up to 35 sq. mm
30Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size Direct-In-Ground including Excavation and Refilling the Trench etc. as required, but Excluding Sand Cushioning and Protective Covering.Up to 35 sq. mm
31Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
32Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia. (OD-63 mm & ID-51 mm nominal)
33Supplying and making straight through joint with Heat Shrinkable Kit including ferrules and other jointing materials for following size of PVC Insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV grade as required.2C x 16 sq. mm
344C x 25 sq. mm
35Supply and Replacement of Pole Connector Box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade-S1 of Outside Dimensions 280 mm (H) x 170 mm (W) x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia. GI Pole with the following Provisions/Accessories Mounting in Box etc. complete as required including rebate for dismantle material.a) 2 Nos. Clamps made out of 19 mm x 3 mm MS Strip of suitable Length for Mounting Box on the Pole.b) Water Tight Front Cover with 2 Nos. Stainless Steel Hinges & 1 No. Screw for Tightening.c) 4-Way, 220 V, 30 A, Dough Moulded Connector with SMC with Stainless Steel Inserts- 1 No.d) 16 A, Moulded SMC Rewireable Kit-Kat- 1 No.e) Suitable size Hole at suitable Location on Rear Wall for Cable & Wire Entry in the Connector Box.f) Earthing Bolt M6 x 20 mm.g) Neutral Link- 1 No.
36Supplying and Replacement of Sewage Treated Water Submersible Pump Set, duly coupled with suitable rating 1-Phase, 220-415 Volts, 50 Hz, 3000 RPM Submersible Motor, including Providing and Fixing of 6 meter long GI Chain of suitable strength for lifting the Pump Set from the UGR/Chamber/Pit etc. complete as required including rebate for dismantle Pump Set. The Pump Set shall be suitable for the following duties:a) Capacity: 2 Hp/1.50 KW (minimum)b) Discharge: 15-600 LPMc) Head Range: 5-15 Meter or 16-49 ftd) Solid Handling Capacity: 35 mme) Outlet Pipe Size: 50 mmf) Suitable Size Cable: 10 Meter (minimum)
37Supplying and Temporary Erection of wrapped timber/balli/bamboo support of suitable size and strength, up to 15 ft overall height, embedded 3 ft into the ground, including vertical alignment and bracing as required; temporary mounting of existing 100 W Flood Light on the erected support with Supply and Fixing of all necessary accessories such as clamps, nuts-bolts, and rassi (binding rope) to ensure safe and secure fixation; complete in all respects for temporary use as directed by the Engineer-in-Charge and/or AE(E)-in-Charge.
38Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
39Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56964754
AUTHORITY Local Bodies
TENDER VALUE 25.81 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh: repair maintenance Of Aeration System In Water Body At Bhalswa Lake, And Annual, Repairing & Maintenance Of Pump Sets, Park & Lake Front Road Lighting, Panel Board Accessories Etc. At Bhalswa Lake Park Of Hd-10 Under North Zone.
Basic Detail
Tender No 34/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 14 Aug 2026
Submission Date 17 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 25.81 Lakhs
Tender Fee Ref. Documents
EMD 51621
Exemption Available
Document List
8d1fb825-0f7f-4ad2-97a7-2c6146f4a8c0.html
BOQ_968596.xls
NIT34.pdf
PressNotice34.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

8d1fb825-0f7f-4ad2-97a7-2c6146f4a8c0.html

xls

BOQ_968596.xls

pdf

NIT34.pdf

pdf

PressNotice34.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders