Tender For Modernization / Upgradation Of Existing Parks/ Green Belt.Sh: Augmentation Of Dda Park With 4 Mtr. Poles, 45 Watt Led Street Light And Allied Accessories At Dr. Hedgewar Park & Nhp Janakpuri L-Shape And Supplying And Fixing Of Rgb Lights W
Tender Overview
Project Description
Tender for Modernization / Upgradation Of Existing Parks/ Green Belt.Sh: Augmentation Of Dda Park With 4 Mtr. Poles, 45 Watt Led Street Light And Allied Accessories At Dr. Hedgewar Park & Nhp Janakpuri L-Shape And Supplying And Fixing Of Rgb Lights With Controller And Other Allied Accessories To The Fountain At Dr. Hedgewar Park, Kirti Nagar Under Horticulture Zone.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Aug-2026 | Corrigendum | Other | 18-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Fabrication and Installation of 4 mtr. high Pole made out of 65 mm dia. NB, B class GI Pipe ISI marked duly welded with MS Base Plate of size 300 mm x 300 mm x 12 mm thick and supported with 4 Nos. Stiffner made out of 130 mm x 60 mm x 5 mm thick with suitable Earth Stud on Base Plate and Collar type mounting arrangement (Double Fitting type both with Hand Length of 0.5 mtr.) for Light Fitting on the Pole, making suitable size Hole in Pole at a Height of 2.5 metre from Base Plate for Cable Entry/Exit, Painting & Numbering of Pole, making suitable size hole in Base Plate for Cable Entry/Exit into the Pole and Fixing the Pole on the Foundation with the nuts-bolts, washers etc. complete as required. |
| 2 | Providing and Laying in Position, 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded Stone Aggregate) Reinforced Cement Concrete Foundation of size 450 mm x 450 mm x 1200 mm deep (800 mm below Ground Level and 400 mm above Ground Level) including excavation of earth, refilling, providing, cutting, bending and placing in position, Reinforcement of Cold Twisted Bars of 12 mm dia.- 1200 mm long (approx.)- 8 Nos. and Reinforcement Ring of Cold Twisted Bar of 8 mm dia.- 1400 mm long (approx.)- 6 Nos. (with suitable spacing) including centering & shuttering as required with Providing, Fixing and Positioning of One Set of Foundation Bolts comprising of 4 Nos., 16 mm dia. 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 Nos. GI nuts and 2 Nos. GI washers etc. per bolt and 1 No. anchor plate (3 mm thick) of suitable size and providing 63 mm (OD) DWC pipe ISI marked for cable entry & exit etc. complete as required. |
| 3 | Supplying, Installation, Testing & Commissioning of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).45 Watt |
| 4 | Supply and Installation of Pole Connector Box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade-S1 of Outside Dimensions 280 mm (H) x 170 mm (W) x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65 mm dia. GI Pole with the following Provisions/Accessories Mounting in Box etc. complete as required.a) 2 Nos. Clamps made out of 19 mm x 3 mm MS Strip of suitable Length for Mounting Box on the Pole.b) Water Tight Front Cover with 2 Nos. Stainless Steel Hinges & 1 No. Screw for Tightening.c) 4-Way, 220 V, 30 A, Dough Moulded Connector with SMC with Stainless Steel Inserts- 1 No.d) 16 A, Moulded SMC Rewireable Kit-Kat- 1 No.e) Suitable size Hole at suitable Location on Rear Wall for Cable & Wire Entry in the Connector Box.f) Earthing Bolt M6 x 20 mm. |
| 5 | Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required.2C x 16 sq. mm |
| 6 | 4Cx25 sq. mm |
| 7 | Supplying and drawing of following sizes FRLS PVC Insulated Copper Conductor, Single Core Cable in the existing surface/recess steel/PVC conduit as required.3C x 1.5 sq.mm |
| 8 | Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size Direct-In-Ground including Excavation and Refilling the Trench etc. as required, but Excluding Sand Cushioning and Protective Covering.Up to 35 sq. mm |
| 9 | Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.Up to 35 sq. mm |
| 10 | Supplying and Replacement of Collar type Bracket of suitable dia. on the Existing Pole duly welded with 2 Nos. of Hand of 0.5 mtr. Each (Both Hands shall be 180 Degree apart) i/c Dismantling and Re-Fixing of the Existing Fitting, tightening with nut bolts etc. complete as required. |
| 11 | Providing and Fixing 6 SWG dia. GI Wire on Surface or in Recess for Loop Earthing along with Existing Surface/Recessed Conduit/Sub-Main Wiring/Cable as required. |
| 12 | Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 13 | Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required. |
| 14 | SITC of underwater Luminaries surface mounted RGB LED Spot Light 6 x 3W with IP 68 protection, SS/aluminium dia. casting body with power coated paint, soft rubber gasket along with 2 years free replacement guaranty etc. complete as required. |
| 15 | Supplying, Installation, Testing and Commissioning of Fixing of Power Supply/SMPS for suitable to run LED Lights, Body-Metal Input Power-220 V AC/Output Power-12 V DC (sufficient for 40 Nos. of 6x3 Watt RGB Lights or more for this case) etc. complete as required. |
| 16 | Supplying, Installation, Testing and Commissioning of RGB Controller with Remote Kit Wattage not less than 200 Watt (sufficient for 40 Nos. of 6x3 Watt RGB Lights or more for this case) i/c connection along with 2 Years free Replacement Guaranty etc. complete as required. |
| 17 | Supplying, Installation, Testing and Commissioning of Fixing of Suction Screen Stainer made of ABS to be fitted in Suction to Protect the Pump from Enrty of External materials etc. complete as required. |
| 18 | Supplying and Drawing following sizes of FRLS/HFFR PVC Insulated Copper Conductor, Single Core Cable in the Existing Surface/Recessed Steel/PVC Conduit i/c making water proof joint connection, testing etc. complete as required.4 x 1.5 sq. mm |
| 19 | SITC of Single Jet Crown Nozzles complete with Ball Joint for 15 Degree Pivoting made of Brass with Nickle Plating, Flow Straightner in following size. Height of water stream up to 10 mtrs. etc. complete as required.25 mm internal threaded with 12 mm orfice. |
| 20 | Shifting of the Existing Feeder Panel at some other Location in the Same Park i/c Dismantling of Foundation of Panel & Wiremesh both and Relaying it other Location in the Same Park i/c connection with thimbles, terminal lugs connectors testing, casting of Foundation etc. complete as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender