Project Description

Tender for Centralized Air-Conditioning For Auditorium At Saharanpur C Us, Iit Roorkee.

BOQ

Name of Work:- Centralized Air-Conditioning for Auditorium at Saharanpur C us, IIT Roorkee.
Sl. No. Item Description
1PART A (Supply Installation Testing and Commissioning)
2Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping.
3The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC Building) For Cooling and Heating (Both)
416 HP
5Supply, installation, testing and commissioning of Controller/Manager with touch screen display accessible through remote views to include the indoor plan layout view, icon view and list view and menus for system configurations. This will allow the users to put limitations on the maximum and minimum temperatures and ensures an appropriate room temperature. This system shall be compatible with connecting Minimum 256 nos. indoor units and remote access to a PC/ BMS through LAN/Wi-fi network. The controller enables monitoring of the VRF system's operation, including temperature, fan speed, and other parameters.
6Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs
7Indoor Units
8Outdoor Multi Joints
9Floor Standing outdoor Type DX AHU
10AHU Construction: - Supply, installation, testing and commissioning of factory built floor mounted double skin type DX Air Handling Units made of 48+/-2 mm thick panels (Density:40+/-2 KG/Cu.m.) consisting of G.I. Casing of thickness 0.8 mm pre-coated outside layer and 0.8 mm thick GI sheet inside layer with polyurethene foam (PUF) insulation factory injected between them by injection moulding machine, complete with plug fan suitable for static pressure as detailed below, cooling coil section with machanically bonded aluminium finned copper tubes (tube thickness not less than 0.3 mm) cooling coil, filter section with filter having filteration efficiency and particle size matching TEFC drive motor suitable for 415+10% volts, 50 + 3% Hz, 3 phase, A.C. supply, minimum IP 55, drain connections, with stainless steel drain pan duly insulated , and necessary vibration isolation arrangement etc. complete as per specifications and drawings of following capacities.
11The unit shall be supplied with electronic expansion valve/s (Dx), thermostat/s, control wiring and corded remote & all accessories as required for completing the installation. The price shall be inclusive of these items. AHUs shall be of following design parameters:
12Cooling Coil: -COIL- 1 No. 6 Row deep DX cooling coil of Copper material with tube thickness of 0.3 mm Copper and Aluminium fins with fin spacing 11-13 fin/inch and Copper Header, Coil size shall be selected for air velocity of 500 ft/minute. Condensing tray of 22G SS-304 material.
13Fan and Motors: - AHU must have Airfoil design direct driven centrifugal Fan with IE3 energy efficiency motor. Fan motors shall be energy efficient with IE-3 grade with IP-55 protection. Motors shall be especially designed for quiet operation. Drive to fan shall be provided through Direct drive arrangement. Fans impeller shall be selected for minimum efficiency of 75%. Fan section with SISW centrifugal direct driven plug fan,motor and spring isolators and IP-20 VFD.
14Mixing Box: - Mixing box should have low leakage damper . The section should maintain proper length for proper air circulation.
15Accessories:LED light with cable; view port and cable gland should provide in fan sections by manufacturer (to protect further leakage).
16Filter section with 50 mm thick box type pre-filter (MERV-8) and Filter section with EAC filter with carbon filter.UVGI section with UV lamp.
17AHU sound pressure level should not be more than 78 db(A) at the distance of 1m from the unit.
18Unit Should have: Mixing box, Filter sections with , Coil section, Fan section.
19Supply/Return Air - The air handling units should have aluminium volume control dampers with % Open & Close marking
20There will be access door across every section of AHU. Vendor should have to take approval on type of Doors (Hinge type or removable type)
21Variable Frequency Device (VFD)
22Vibration isolators.
23General specifications of AHU shall be as mentioned below:
2410000 CFM, 65 mmwg External Static Presure,Motor Kw- 7.5 KW, 6 Row Deep DX Coil.
25Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
266.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
279.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
2812.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
2915.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
3019 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
3122.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
3228.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
3334.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
3441.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
35Supply and applying of fibre glass cloth equal to Parafab-GFC (7mil) used protection of exposed pipe insulation with two coat of starbond 30-36 thermal insulation coating.
36Supply, Installation, testing and commissioning of 10 KG Presure PVC pipe 25 mm dia size with 6 MM Nitrile insulation, complete with fittings, supports accessories in surface/recess as per specifications & site requirments
37Supply, Installation, testing and commissioning of 10 KG Presure PVC pipe 32 mm dia size with 6 MM Nitrile insulation, complete with fittings, supports accessories in surface/recess as per specifications & site requirments
38Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc. as required complete and all respect in confimtion with IS: 655 and approved drawings and specifications of following sheet thickness complete as required.
39Thickness 0.63 mm sheet
40Thickness 0.80 mm sheet
41Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc. as required complete and all respect in confimtion with IS: 655 and approved drawings and specifications of following sheet thickness complete as required.
42Thickness 0.63 mm sheet
43Thickness 0.80 mm sheet
44Supplying and fixing of 19 MM thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
45Supplying and fixing of following thickness duly closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
4613 MM Thick
479 MM Thick
48Supply, Installation, Testing and Commissioning of 15mm thick ecosound (FR-Open Cell Cross Linked Polyethylene) for supply & return air ducts Acoustic lining inside ducts using Non Fibrous fire retardant crosslinked polyethylene foam of 30-60 +/- 3 Kg/m3 density & thickness of 15mm having porous surface on one side & a flat surface on other side using Synthetic rubber based Adhesive preferably Low VOC & high strength characteristic(Initial portion of ducting and main plenum) as per specifications
49Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specififications complete etc. as required
50Supplying & fixing of powder coated extruded aluminium supply Air Grills with aluminium volume control dampers complete in confirmation to SMACNA/IS and as per specififications complete etc. as required
51Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core complete in confirmation to SMACNA/IS and as per specififications complete etc. as required
52Supplying, fixing testing commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring and removable core complete in confirmation to SMACNA/IS and as per specififications complete etc. as required
53Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, in confirmation to SMACNA/IS and as per specififications complete etc. as required
54Supply and fixing of double layer Canvas connection for ductable uniit.
55SITC of 3 phase fully utomatic star delta motor starter 6 to 15 HP, relay range 4 to 18 Amp, along with all accssories complte with all connection as required.
56Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor/wall mounted/ recessed/ surface feeder pillar / Panel double/ Single door , 150-200 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. Ampere meter, Volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB's/MCCB's, C/o switch with extentionable/rotary handle etc.) as required. The feeder pillar/ panel shall have nonhygroscopic supports with detachable side with hinge and locking. The panel/ feeder pillar should be made with 1.6 CRCA sheet. The panel shall be comprised of indicator and feeder nomenclature (if required) as per direction of site-in-charge.
57Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor/wall mounted/ recessed/ surface feeder pillar / Panel double/ Single door , 200-250 mm depth duly powder coated spray painted with suitable Busbar up to 250 Amp capacity as required and separate chamber for instruments e.g. Ampere meter, Volt meter, frequency meter, KWH meter etc. & chamber for switch gears (like I/C & O/G MCB's/MCCB's, C/o switch with extentionable/rotary handle etc.) as required. The feeder pillar/ panel shall have nonhygroscopic supports with detachable side with hinge and locking. The panel/ feeder pillar should be made with 1.6 CRCA sheet. The panel shall be comprised of indicator and feeder nomenclature (if required) as per direction of site-in-charge.
58Providing and fixing 250 A, 35 KATPMCCB and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
59Supply and laying of aluminium conductor, XLPE insulated, armoured, PVC sheathed cable, 1100V grade, 3.5 core 185 mm² on existing RCC / HUME / METAL Pipe of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc.
60Supply and laying of aluminium conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V grade, 3.5 core 185 mm² at a depth of 750 mm below ground level including excavation and refling the trench over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly.
61Supplying and making end termination with brass compression gland and aluminium lugs for 3 ½/ 4 core 185 mm²(57 mm) PVC cable insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.
62Supplying and fixing of 25 MM medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
63Supply and laying of following sizes Copper conductor, XLPE insulated, armoured, PVC sheathed cable, 1100V grade on existing cable tray with M.S. clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc.
644 core 16 Sq mm
654 core 10 Sq mm
664 core 6 Sq mm
674 core 4 Sq mm
682C x 1.5 Sq mm.
693 core 1.5 Sq mm.
70Supply and laying of Copper conductor, XLPE insulated, Un-armoured, PVC sheathed cable, 1100V grade, 2 core 1.5 mm2 on existing RCC / HUME / METAL Pipe. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc.
71Supplying and drawing 2 X 6 sq.mm of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
72Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
73150 mm width X 50 mm depth X 1.6 mm thickness
74225 mm width X 50 mm depth X 1.6 mm thickness
75300 mm width X 50 mm depth X 1.6 mm thickness
76Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required
77Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
78Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
79Supplying and fixing 40 to 63 amp 4 Pole MCB rating , 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
80Supplying and fixing 40 amp , four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.
81Supplying and fixing 63 amp , four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.
82Supplying and fixing single pole 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
83Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete.
84Painting with synthetic enamel paint of approved brand and manufacture of required colour to given an even shade.
85two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
86Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
87PART B: Comprehensive Annual Maintenance Contract of 96 HP VRF/VRV AC after completion of DLP( i.e. one years after commissioning & handover) in SITC of AC system including AHU's, Emergency fan, ducting, piping, insulation etc.in Auditorium at Saharanpur including replacement of spares.
88First Year CAMC
89Second Year CAMC
90Third Year CAMC
91Fourth Year CAMC
92Fifth Year CAMC
93Sixth Year CAMC (PART-A+PART-B) (PART-A+PART-B) (PARTA+PART B) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56964727
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 01-09-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Centralized Air-Conditioning For Auditorium At Saharanpur C Us, Iit Roorkee.
Basic Detail
Tender No IWD/IE/26-27/RT/E-31
Bidding Type Tender
Location
City Saharanpur
State Uttar Pradesh
Key Dates
Publish Date 11 Aug 2026
Submission Date 01 Sep 2026
Open Date 02 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 1180
EMD 1.90 Lakhs
Exemption Not Available
Document List
13cf6bb8-79a3-4325-b6f6-1d6fbad97e73.html
BOQ_968568.xls
T31.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.