Housing Urban and Rular Development Government Departments Closing in 2 days TDR #56964680

Tender For Special Repair - Rewiring And Renewal Of Sbt Fittings, Fans, Powermain Arrangements To The Primary Health Centre At Ottanatham In Thoothukudi District.

Issued by Government Departments · Tuticorin, Tamil Nadu
Tender Value
2.82 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
2 days left
EMD
2900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tuticorin → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Special Repair - Rewiring And Renewal Of Sbt Fittings, Fans, Powermain Arrangements To The Primary Health Centre At Ottanatham In Thoothukudi District.

BOQ

Name of Work:- SR - Rewiring and renewal of SBT fittings, Fans, Powermain arrangements to the Primary Health Centre at Ottanatham in Thoothukudi District.
Sl. No. Item Description
1Rewiring with 2 x 1.5 sq.mm. PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light /fan point (for electronic regulator) (5 points per coil).
2Renewal by supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.
3Renewal by supply and fixing of 9W LED bulb in the existing BH's.
4Renewal by Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting.
5Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod with fan clamp with side plates and cross arm of size 450mm (18\\").
6Renewal by supply and fixing of 1 No 15A 3 pin combined flush type wall socket with 15A flush type switch and 3 Nos 5A (3 pin & 2 pin) combined flush type wall socket with control switches on suitable TW box covered with hylem sheet in flush with wall with earth connection.
7Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End.
8Renewal by Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 32A 4P MCB as incoming and 12 Nos 6A to 32A SP MCB as outgoing in flush with wall with Earth connection only. Higher End.
9Supply and fixing of 65mm dia GI pipe (Class 'B') 4 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting and construction of masonary pedestal with MS box of 30cm x 20cm x 10cm with angle iron frame work with door and lock and key arrangements with supply and fixing of 60 W LED street light fitting with bulb and with supply and fixing of 1No. 16A fuse unit (500V) and 5A SP switch inside the MS box with PVC unsheathed FRLS leads and painting of suitable colour.
10Supply erection, testing and commissioning of 1.5TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions ofCoolingDehumidifyingAir CirculatingFilteringThe installation works for the above split type AC units includes the following.1. Mounting / Fitting Indoor and outdoor units at their respective locations.
112. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.5. Leakage testing the entire system unit.6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit. (Carrier/Voltas/Blue Star).
12Supply and fixing of 4KVA Electronic Automatic Voltage Stabilizer with Input Voltage range of 170Volt 270 Volt and Output Voltage range 200 Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.
13Renewal by supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour.
14Renewal by supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour.
15Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V on 7/20 GI bearer wire for service connection mains.
16Re - Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work.
17Dismantling charges and Transportation charges of old dismantled electrical materials from work site to section office.
18GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56964680
AUTHORITY Government Departments
TENDER VALUE 2.82 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name public works department
Work Description Tender For Special Repair - Rewiring And Renewal Of Sbt Fittings, Fans, Powermain Arrangements To The Primary Health Centre At Ottanatham In Thoothukudi District.
Basic Detail
Tender No 2(3)EE/2026-27 dated.06.08.2026
Bidding Type Tender
Location
City Tuticorin
State Tamil Nadu
Key Dates
Publish Date 12 Aug 2026
Submission Date 27 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 2.82 Lakhs
Tender Fee Ref. Documents
EMD 2900
Exemption Not Available
Document List
19HSCOttanatham.pdf
4bec1ba1-18d9-4f30-8db4-c94d7471e3f0.html
BOQ_833133.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
pdf

19HSCOttanatham.pdf

html

4bec1ba1-18d9-4f30-8db4-c94d7471e3f0.html

xls

BOQ_833133.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders