Drinking Water Supply and Sanitation Government Departments Closing in 4 days TDR #56964446

Tender For INSTALLATION Of Dam Instruments At Jigaon Project Tal Nandura Dist.Buldhana

Issued by Government Departments · Buldhana, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Aug 2026
4 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Buldhana → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for INSTALLATION Of Dam Instruments At Jigaon Project Tal Nandura Dist.Buldhana

BOQ

Name of Work:- Instalation of Dam Instruments at Jigaon Project Tal Nandura Dist.Buldhana
Sl. No. Item Description
1Providing and installing Long Guage Extensometer Multiplebore hole Extenssometer For Concrete Spillway.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
2Providing and installing Tiltmeter For Concrete Spillway.Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
3Providing and installing Temperature Stress For Concrete Spillway.Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
4Providing and installing Laser Plumb bob For Concrete Spillway.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
5Providing and installing Pore pressure Transducers For Earthen Dam.Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
6Providing and installing Casagrande/ Stand Pipe Piezometer For Earthen Dam.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
7Providing and installing Horrizontal/ Vertical/ Cross arm Surface settlement plug For Earthen Dam.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
8Providing and installing Earth pressure Cells For Earthen Dam.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
9Providing and installing 2 Pair ,4 core Armoured Jelly filled 7/0.34 mm annealed copper, petroleum jelly filled, 0.5 mm Ø galvanized steel wire armoured cable with Splicing Kit, water proof label and proper harnessing and protection cover with VW read out unit for 622 sensors as per direction of Engineer Incharge etc complete.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
10Providing and installing 10 P, 20 core 7/0.25 mm ATC, twisted pairs screened with water blocking aluminum foil, 0.3 mm galvanized iron wire braid armoured Jelly filled cable with Splicing Kit, water proof label and proper harnessing and protection cover with VW read out unit for connecting sensors to data logger units as per direction of Engineer Incharge etc complete.Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
11Providing and installing of 10 Channel Junction Box and IP67 enclosure of 650mm Lenght x 550mm Height x 250mm depth along with sensor cable termination into the junction box in the gallery. Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
12Providing16 channel Data Multiplexer for VW sensor with following specificiation and connecting sensor cables as - a. Power Unregulated 9.6 to 16 Vdcb. Maximum Actuation Time for Relay - 20 msc. Relay Operation - Break before maked. Maximum Switching Current - 500 mAe. Maximum Switching Voltage - 50 Vdcf. Minimum Contact Life - 5 x 107 operationsg. Operating Temperature Range-55° to +85°Cwith the connectivity to data logger for selection of the channel to be read. Installation and demonstration as per guidance of the site engineer complete with all accessories. Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
13Providing and installing of multi-Channel Data Logger for VW sensors with the following specification with power supply and cables connecting data logger and multiplexers and to workstation software with accessories as per guidance of the site engineer.Power requirements - 1. Power inputs are protected against surge, over voltage, over-current, and reverse power. IEC 61000-4 Class 4 level 2. Input from Power converter or solar panel Storage Requirements3. Total onboard: 128 MB of flash + 4 MB battery-backed SRAM 4. Data storage expansion: Removable microSD flash memory, up to 16 GB Software Requirements:1. Should be able to interface to PC base application through USB/Ethernet etc Software should be able to configure VW sensors and thermistors a Software should be able to configure and generate reports as pere requirment for DAM monitoring Static VW measurment specificaitons 1. Input Resistance: 4.75kOhm2. Mearurement type: differencial voltage 3. Range: +/_ 200mV 4. Accuracy: +/_ 0.02% reading 5. Resolution: 0.001 Hz RMS 6. Measurement Speed (Vibrating wire and thermister Combined) <1s Thermister measurement specifications 1. Input Resistance - 5KOhm +/_ 0.1%, 10ppm/deg C 2. Measuremnt Type: single ended Voltage3. Range +/_5000 mV 4. Resolution: 0.001 Ohms 5. Accuracy: +/_ 0.25% reading Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
14Providing hot dipped galvanised laddr type cable tray manufactured from 16 SWG (1.6 mm Thick)GI sheet of150mm width and 75 mm height complete with necessary coupler plates and hardware.: Qty 300 MTRSpecification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
15Providing hot dipped galvanised laddr type cable tray manufactured from 16 SWG (1.6 mm Thick)GI sheet of 200 MM width and 75 mm height : Qty 300 MTRSpecification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
16Providing hot dipped galvanised laddr type cable tray manufactured from 16 SWG (1.6 mm Thick)GI sheet of 300 MM width and 75 mm height :Qty 425 MTR Mounting/fixing on the wall of the gallery and laying out cables as per guidance of the engineer.Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
17Providing and installing of Software for Data logging and Data visualitaion. (Acquisition and expansion for cloud) 1. Continuous reading of sensors.2. Connect and collect to all instruments and data producers (non VW and Thermister) such as Rainguage, Ambient air quality, Earthern Dam parameters and manual entry.3. Maintain the record of sensor calibration 4. Data visualisation of the dam parameters through the sensor data 5. Create and circulate reports of dam conditionas per direction of Engineer Incharge, Complete with required manuals and two month of onsite operational training and reporting to site engineers. Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
18Providing and installing of Bowl with Galavinised plating 10\\"dia X 7\\" Height as per instrumentation drawing and direction of Engineer Incharge etc complete.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
19Providing and installing of 50 mm S. S Pipe with SS Coupling 1.5\\" dia, threaded, SS Socket 1.5\\" X 4\\" long, threaded, SS Bend 1.5\\" threaded as per direction of Engineer Incharge etc complete.SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
20Providing and installing Casagranda/Sandpipe, 37 mm dia 6mm wall thickness and 60 cm long porous tube piezometer piezometer material, drilling and installation for 11 sensors with Bentonite, UPVC pipe with GI pipe with Brass cap and concrete platform as per direction of Engineer Incharge etc complete installation as specified in IS 7356 part-ISpecification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
21Providing and installing Water level indicator for Casagranda as per direction of Engineer Incharge etc with stainless steel probe and indelibly graduated electric measurement cable having graduation at 0.5m interval and 200m length (100m on spool with the deices and 100 m as spare ) as per IS7356 PartI 2002SpecificationMeasurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
22Providing and installing Work Station, (Latest computer sytem with Monitor )Network Attached Storage (NAS) for long perid data backup.Online UPS 6 KVA online UPS for power backup as per direction of Engineer Incharge etc complete for -Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
23Supplying and Installing Electronic type V Notch System(Automatic)Specification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading
24Providing Annual Maintenance contract for five years,(Only technical persons) 1.Take readings of sensors and plotting of graphs (if required interpretation)2. Calibration check and recalibration if required for all sensors.3. Calibration Jigs and refurbishing of equipment's due to wear and tear and weather impacts (such as UPC channels, enclosures, cabling , plumb bob alignment, Rainguages, ambient monitoring equipments, Joint/crack meters etcSpecification Measurement Range: 0–300 mmAccuracy: ±0.1% F.S.Resolution: 0.01 mmProtection: IP68Cable Requirement: Shielded, UV resistant, armoured, 4-coreInstallation: Installed in drilled borehole with anchors at specified depthsCalibration: Factory calibration with traceable certificateAcceptance Tests: Calibration certificate, insulation test, field baseline reading Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56964446
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 19-08-2026
Authority
Authority Name Water Resources Department
Work Description Tender for INSTALLATION Of Dam Instruments At Jigaon Project Tal Nandura Dist.Buldhana
Basic Detail
Tender No Budgetary_Offer_No_01/2026-27
Bidding Type Tender
Location
City Buldhana
State Maharashtra
Key Dates
Publish Date 12 Aug 2026
Submission Date 19 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
4f70c7dc-1acf-44cb-aed9-88423d1ea7e6.html
BOQ_2273058.xls
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

4f70c7dc-1acf-44cb-aed9-88423d1ea7e6.html

xls

BOQ_2273058.xls

pdf

NIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender