Tender For Drilling Of New Bore Wells, Flushing Of Existing Bore Wells, Repair And Reconditioning Of Pump Sets For The Following Thayamanagalam Cwss In Sivagangai District Under State Drought Relief Fund. (2026-27)
Tender Value
38.05 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
3 days left
EMD
20000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sivaganga → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Drilling Of New Bore Wells, Flushing Of Existing Bore Wells, Repair And Reconditioning Of Pump Sets For The Following Thayamanagalam Cwss In Sivagangai District Under State Drought Relief Fund. (2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | CWSS TO THAYAMANGALAM AND 73 OTHER HABITATION IN ILAYANGUDI AND KALAYARKOIL UNIONS OF SIVAGANGAI DISTRICT UNDER STATE DROUGHT RELIEF FUND. |
| 2 | Add GST @ 18% Please Enable Macros to View BoQ information Schedule A Name of the Work : Drilling of new bore wells, flushing of Existing Bore wells, Repair and reconditioning of pump sets for the following Thyamangalam CWSS in Sivagangai District Under State Drought Relief Fund. (2026-27) Sl.No Description of work Basic Amount (In Rupees) GST 18 % (In Rupees) Amount In Rupees |
| 3 | Thayamangalam CWSS Total 3225299.82 580553.97 3805853.79 Schedule A Name of the Work : Drilling of new bore wells, flushing of Existing Bore wells, Repair and reconditioning of pump sets for the following Thyamangalam CWSS in Sivagangai District Under State Drought Relief Fund. (2026-27) Sl.No DESCRIPTION QTY Specifications unit Rate in Rs. Amount in Rupees In figures In words A Thayamanagalam CWSS |
| 4 | Drilling 140mm/150mm Pilot Bore upto 60m depth ending below GL. P.No.218 |
| 5 | Reaming from 140mm / 150mm dia pilot bore to 300mm dia bore as directed by the TWAD Bd., officers upto 60M depth ending from GL |
| 6 | upto 60m depth ending from GL.P.219 |
| 7 | Labour charges for inserting 150mm dia PVC casing pipes assembly (with slots or without slots) in the drilled hole including the jointing the pipes with PVC couplers with cement paste etc. complete.P.221 |
| 8 | 165mm/168mm dia. PVC casing pipes assembly |
| 9 | Charges for developing the borewell with air compressor of 300 cfm capacity (Minimum 8 hours) including transportation labour and fuel charges for compressor as directed by TWAD Board officers and conducting yield test by 'V' Notch method.P.223 |
| 10 | Supply and Delivery of un plasticized for plain PVC casing pipes for the following diameters in 3m length with screwed and Socket ends and centering guides for every 15m length of pipes as per IS 12818 / 1992 and as amended from time to time to suit deep borewells upto 80m depth (CS) for delivery at site with ISI marking including loading unloading, freight, transit insurance and inclusive of all taxes etc complete.P.No.6 |
| 11 | 150mm OD PVC plain casing pipes. |
| 12 | Supply and Delivery of un plasticized ribbed screen PVC casing pipes for the following diameters in 3m length with screwed and Socket ends and centering guides for every 15m length of pipes as per IS 12818 / 1992 and as amended from time to time to suit deep bore wells up to 80m depth (CS) for delivery at site with ISI marking including loading unloading, freight, transit insurance and inclusive of all taxes etc complete. P.No6 |
| 13 | 150mm OD PVC Ribbed screen casing pipes. |
| 14 | Supply and Delivery of 150 mm dia PVC borewell cap (P.No.215) No's 2.0 490900.7 |
| 15 | Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mmdia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capableof discharging noted LPM against head of water column due to all causes. The pump shall bewith stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screwsand CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to acontinous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283/1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ+/- 5 % DUTY OF PUMPSETS |
| 16 | 100 LPM X 225 M - 35.0 HP (Item No.3.1 /P.No.120/ SOR 2025 26) |
| 17 | Supply and delivery of Star-Delta starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/ 50HZ(+/-5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressedscale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature circuitrbraeker, Thermal Overload relay, Air Break contactors suitable for nextStandard higher KW rating, Single phasing preventor, dry running preventorand On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvcinsulated cable, power capacitor(thecoated vermin proof box, including the cost of capacitor is to be taken separately) |
| 18 | 10 HP (Item No.3.1 /P.No.120/ SOR 2025 26) L.T. CABLES |
| 19 | PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER (Item No.12.1 /P.No.124/ SOR 2024-25) 4.0 sq.mm |
| 20 | Laying the above cable as per IE rules from the between Transformer to rhe panel board |
| 21 | JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER(Item No.12.2-II /P.No.125/ SOR 2024-25) |
| 22 | Supply and delivey of pipes and specials including laying and jointing etc complete. |
| 23 | 50 mm GI Pipe |
| 24 | 50 mm GI Coupling |
| 25 | 50 mm GI Bend |
| 26 | 50 mm GI Flange set |
| 27 | 50 mm GI Tee |
| 28 | 50 mm GM Gate valve |
| 29 | 50 mm Non Return valve |
| 30 | 50 mm MS Clamp set |
| 31 | 50 mm GI Hex Nipple |
| 32 | 50 mm GI Flange set rubber |
| 33 | Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be de signed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. DUTY OF PUMPSETS |
| 34 | 400 LPM X 60 M - 15.0 HP (Item No.3.1 /P.No.123/ SOR 2025 26) |
| 35 | Supply and delivery of Star-Delta starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/ 50HZ(+/-5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressedscale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature circuitrbraeker, Thermal Overload relay, Air Break contactors suitable for nextStandard higher KW rating, Single phasing preventor, dry running preventorand On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvcinsulated cable, power capacitor(thecoated vermin proof box, including the cost of capacitor is to be taken separately) |
| 36 | 15 HP (Item No.3.1 /P.No.134/ SOR 2025 26) L.T. CABLES |
| 37 | PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER (Item No.12.1 /P.No.124/ SOR 2024-25) 4.0 sq.mm |
| 38 | Laying the above cable as per IE rules from the between Transformer to rhe panel board |
| 39 | JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER(Item No.12.2-II /P.No.125/ SOR 2024-25) |
| 40 | Supply and delivey of pipes and specials including laying and jointing etc complete. |
| 41 | 50 mm GI Pipe |
| 42 | 50 mm GI Coupling |
| 43 | 50 mm GI Bend |
| 44 | 50 mm GI Flange set |
| 45 | 50 mm GI Tee |
| 46 | 50 mm GM Gate valve |
| 47 | 50 mm Non Return valve |
| 48 | 50 mm MS Clamp set |
| 49 | 50 mm GI Hex Nipple |
| 50 | 50 mm GI Flange set rubber |
| 51 | Supply and delivery of the following sizes of PVC pipes confirming to IS specifications including transportation charges any where in Tamilnadu and as directed by TWAD Board officers. |
| 52 | 90mm PVC 4 KSC |
| 53 | 63mm PVC 4 Ksc |
| 54 | Supply and delivery of the following sizes of GI pipes confirming to IS specifications including transportation charges any where in Tamilnadu and as directed by TWAD Board officers. |
| 55 | 80MM GI pipe (M) |
| 56 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 57 | 90mm PVC 4 KSC |
| 58 | 63mm PVC 4 Ksc |
| 59 | Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste. |
| 60 | 90mm PVC 4 KSC |
| 61 | 63mm PVC 4 Ksc |
| 62 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 63 | 80MM GI pipe (M) |
| 64 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 65 | 90mm PVC 4 KSC |
| 66 | 63mm PVC 4 Ksc |
| 67 | Rate for flushing of borewell of 6” diarequiring less than 4 hours operation usingdrill rods/ hose with required size of pipesfor various capacity compressor includingtransportation, labour, and fuel charges forcompressors as directed by the TWAD Officerand conducting yield test by ‘V’ notch method if required |
| 68 | 600 Cfm ( 100 /150 PSI) |
| 69 | Rewinding of motor and reconditioning pump and repair works to 7.50 HP Vertical bore well Pump Set (500 LPM X 70 M Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset a Head works -2 Nos |
| 70 | Supply, delivery of PVC insulated and sheathed3 core 4 Sq. mm Copper cable conforming to IS 694/1990 and as amended thereafter for following Wells submersible motor to main panel board. |
| 71 | Laying the above cable as per IE rules from Transformer to the panel board for laying in trenches inside the pump room or in air |
| 72 | Jointing the above cable including the cost of jointing materials, lugs, cable clamp etc, complete, confirming to IS 1554 PART I as amended thereafter with ISI marking Sub Total 3225299.82 |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender