Drinking Water Supply and Sanitation Local Bodies Closing in 3 days TDR #56964071

Tender For Drilling Of New Bore Wells, Flushing Of Existing Bore Wells, Repair And Reconditioning Of Pump Sets For The Following 5 No. Of Cwss In Sivagangai District Under State Drought Relief Fund. (2026-27)

Issued by Local Bodies · Sivaganga, Tamil Nadu
Tender Value
37.81 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
3 days left
EMD
20000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sivaganga → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Drilling Of New Bore Wells, Flushing Of Existing Bore Wells, Repair And Reconditioning Of Pump Sets For The Following 5 No. Of Cwss In Sivagangai District Under State Drought Relief Fund. (2026-27)

BOQ

Name of Work:- Drilling of new bore wells, flushing of Existing Bore wells, Repair and reconditioning of pump sets for the following 5 no. of CWSS in Sivagangai District Under State Drought Relief Fund. (2026-27)
Sl. No. Item Description
1CWSS TO VAYALCHERI AND 19 OTHER HABITATION IN THIRUPPUVANAM UNION OF SIVAGANGAI DISTRICT UNDER STATE DROUGHT RELIEF FUND.
2CWSS TO P.ALANGULAM AND 17 OTHER HABITATION IN MANAMADURAI AND ILAYANGUDI UNIONS OF SIVAGANGAI DISTRICT UNDER STATE DROUGHT RELIEF FUND.
3CWSS TO ANUKKANENDAL AND 7 OTHRE HABITATION IN KANNANKUDI UNION OF SIVAGANGAI DISTRICT UNDER STATE DROUGHT RELIEF FUND.
4CWSS TO ERIVAYAL AND 13 OTHER HABITATION IN KALAYARKOIL UNION OF SIVAGANGAI DISTRICT UNDER STATE DROUGHT RELIEF FUND.
5CWSS TO PALUVOOR AND 12 OTHER HABITATION IN KALAYARKOIL UNION OF SIVAGANGAI DISTRICT UNDER STATE DROUGHT RELIEF FUND.
6Add GST @ 18% Please Enable Macros to View BoQ information Schedule A Name of the Work : Drilling of new bore wells, flushing of Existing Bore wells, Repair and reconditioning of pump sets for the following 5 nos. of CWSS in Sivagangai District Under State Drought Relief Fund. (2026-27) Sl.No Description of work Basic Amount (In Rupees) GST 18 % (In Rupees) Amount In Rupees
7Vayalcheri CWSS
8P.Alangulam CWSS
9Anukkanendal CWSS
10Erivayal CWSS
11Paluvoor CWSS Total 3204350.16 576783.02 3781133.18 Schedule A Name of the Work : Drilling of new bore wells, flushing of Existing Bore wells, Repair and reconditioning of pump sets for the following 5 nos. of CWSS in Sivagangai District Under State Drought Relief Fund. (2026-27) Sl.No DESCRIPTION QTY Specifications unit Rate in Rs. Amount in Rupees In figures In words A Vayalcheri CWSS
12Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete.
13Infiltration Well - I
14Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. DUTY OF PUMPSETS
15350 LPM X 47 M - 5.0 HP (Item No.3.1 /P.No.120/ SOR 2025 26)
16Supply and delivery of Star-Delta starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/ 50HZ(+/-5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressedscale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature circuitrbraeker, Thermal Overload relay, Air Break contactors suitable for nextStandard higher KW rating, Single phasing preventor, dry running preventorand On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvcinsulated cable, power capacitor(thecoated vermin proof box, including the cost of capacitor is to be taken separately)
1710 HP (Item No.3.1 /P.No.120/ SOR 2025 26) L.T. CABLES
18PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER (Item No.12.1 /P.No.140/ SOR 2025-26) 4.0 sq.mm
19Laying the above cable as per IE rules from the between Transformer to rhe panel board
20JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER(Item No.12.2-II /P.No.142/ SOR 2025-26)
21Supply and delivey of pipes and specials including laying and jointing etc complete.
2250 mm GI Pipe
2350 mm GI Coupling
2450 mm GI Bend
2550 mm GI Flange set
2650 mm GI Tee
2750 mm GM Gate valve
2850 mm Non Return valve
2950 mm MS Clamp set
3050 mm GI Hex Nipple
3150 mm GI Flange set rubber
32Supply and delivery of the following sizes of PVC pipes confirming to IS specifications including transportation charges any where in Tamilnadu and as directed by TWAD Board officers.
3390mm PVC 4 KSC
3463mm PVC 4 Ksc
35Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
3690mm PVC 4 KSC
3763mm PVC 4 Ksc
38Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
3990mm PVC 4 KSC
4063mm PVC 4 Ksc
41Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
4290mm PVC 4 KSC
4363mm PVC 4 Ksc
44Rate for flushing of borewell of 6” diarequiring less than 4 hours operation usingdrill rods/ hose with required size of pipesfor various capacity compressor includingtransportation, labour, and fuel charges forcompressors as directed by the TWAD Officerand conducting yield test by ‘V’ notch method if required
45600 Cfm ( 100 /150 PSI)
46Rewinding of motor and reconditioning pump and repair works to 5 HP Vertical bore well Pump Set (75 LPM X 100 M Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset a Head works -2 Nos
47Supply, delivery of PVC insulated and sheathed3 core 4 Sq. mm Copper cable conforming to IS 694/1990 and as amended thereafter for following Wells submersible motor to main panel board.
48Laying the above cable as per IE rules from Transformer to the panel board for laying in trenches inside the pump room or in air
49Jointing the above cable including the cost of jointing materials, lugs, cable clamp etc, complete, confirming to IS 1554 PART I as amended thereafter with ISI marking Sub Total 702151.95 P.Alangulam CWSS
50Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete.
51Infiltration Well - I
52Supply and delivery of the following sizes of PVC pipes confirming to IS specifications including transportation charges any where in Tamilnadu and as directed by TWAD Board officers.
5390mm PVC 4 KSC
54Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
5590mm PVC 4 KSC
56Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
5790mm PVC 4 KSC
58Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
5990mm PVC 4 KSC
60Rate for flushing of borewell of 6” diarequiring less than 4 hours operation usingdrill rods/ hose with required size of pipesfor various capacity compressor includingtransportation, labour, and fuel charges forcompressors as directed by the TWAD Officerand conducting yield test by ‘V’ notch method if required
61600 Cfm ( 100 /150 PSI)
62Rewinding of motor and reconditioning pump and repair works to 7.50 HP Vertical bore well Pump Set (500 LPM X 70 M Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset a Head works -2 Nos
63Supply, delivery of PVC insulated and sheathed3 core 4 Sq. mm Copper cable conforming to IS 694/1990 and as amended thereafter for following Wells submersible motor to main panel board.
64Laying the above cable as per IE rules from Transformer to the panel board for laying in trenches inside the pump room or in air
65Jointing the above cable including the cost of jointing materials, lugs, cable clamp etc, complete, confirming to IS 1554 PART I as amended thereafter with ISI marking Sub Total 982668.11 Anukkanendal CWSS
66Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mmdia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capableof discharging noted LPM against head of water column due to all causes. The pump shall bewith stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screwsand CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to acontinous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283/1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ+/- 5 % DUTY OF PUMPSETS
67125 LPM X 100 M - 5.0 HP (Item No.3.1 /P.No.120/ SOR 2025 26)
68Supply and delivery of Star-Delta starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/ 50HZ(+/-5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressedscale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature circuitrbraeker, Thermal Overload relay, Air Break contactors suitable for nextStandard higher KW rating, Single phasing preventor, dry running preventorand On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvcinsulated cable, power capacitor(thecoated vermin proof box, including the cost of capacitor is to be taken separately)
695 HP (Item No.3.1 /P.No.120/ SOR 2025 26) L.T. CABLES
70PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER (Item No.12.1 /P.No.124/ SOR 2024-25) 4.0 sq.mm
71Laying the above cable as per IE rules from the between Transformer to rhe panel board
72JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER(Item No.12.2-II /P.No.125/ SOR 2024-25)
73Supply and delivey of pipes and specials including laying and jointing etc complete.
7450 mm GI Pipe
7550 mm GI Coupling
7650 mm GI Bend
7750 mm GI Flange set
7850 mm GI Tee
7950 mm GM Gate valve
8050 mm Non Return valve
8150 mm MS Clamp set
8250 mm GI Hex Nipple
8350 mm GI Flange set rubber
84Rate for flushing of borewell of 6” diarequiring less than 4 hours operation usingdrill rods/ hose with required size of pipesfor various capacity compressor includingtransportation, labour, and fuel charges forcompressors as directed by the TWAD Officerand conducting yield test by ‘V’ notch method if required
85600 Cfm ( 100 /150 PSI)
86Rewinding of motor and reconditioning pump and repair works to 7.50 HP Vertical bore well Pump Set (500 LPM X 70 M Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset a Head works -2 Nos
87Supply, delivery of PVC insulated and sheathed3 core 4 Sq. mm Copper cable conforming to IS 694/1990 and as amended thereafter for following Wells submersible motor to main panel board.
88Laying the above cable as per IE rules from Transformer to the panel board for laying in trenches inside the pump room or in air
89Jointing the above cable including the cost of jointing materials, lugs, cable clamp etc, complete, confirming to IS 1554 PART I as amended thereafter with ISI marking Sub Total 466474.8 Erivayal CWSS
90Supply and delivery of the following sizes of PVC pipes confirming to IS specifications including transportation charges any where in Tamilnadu and as directed by TWAD Board officers.
9163mm PVC 4 Ksc
92Supply and delivery of the following sizes of GI pipes confirming to IS specifications including transportation charges any where in Tamilnadu and as directed by TWAD Board officers.
9350MM GI pipe (M)
94Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
9563mm PVC 4 Ksc
96Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
9763mm PVC 4 Ksc
98Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
9950MM GI pipe (M)
100Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
10163mm PVC 4 Ksc
102Rate for flushing of borewell of 6” diarequiring less than 4 hours operation usingdrill rods/ hose with required size of pipesfor various capacity compressor includingtransportation, labour, and fuel charges forcompressors as directed by the TWAD Officerand conducting yield test by ‘V’ notch method if required
103600 Cfm ( 100 /150 PSI)
104Rewinding of motor and reconditioning pump and repair works to 7.50 HP Vertical bore well Pump Set (500 LPM X 70 M Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset a Head works -2 Nos
105Supply, delivery of PVC insulated and sheathed3 core 4 Sq. mm Copper cable conforming to IS 694/1990 and as amended thereafter for following Wells submersible motor to main panel board.
106Laying the above cable as per IE rules from Transformer to the panel board for laying in trenches inside the pump room or in air
107Jointing the above cable including the cost of jointing materials, lugs, cable clamp etc, complete, confirming to IS 1554 PART I as amended thereafter with ISI marking
108Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be de signed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. DUTY OF PUMPSETS
109100 LPM X 75 M - 5.0 HP (Item No.3.1 /P.No.123/ SOR 2025 26)
110Supply and delivery of Star-Delta starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/ 50HZ(+/-5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressedscale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature circuitrbraeker, Thermal Overload relay, Air Break contactors suitable for nextStandard higher KW rating, Single phasing preventor, dry running preventorand On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvcinsulated cable, power capacitor(thecoated vermin proof box, including the cost of capacitor is to be taken separately)
1115 HP (Item No.3.1 /P.No.134/ SOR 2025 26) L.T. CABLES
112PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER (Item No.12.1 /P.No.124/ SOR 2024-25) 4.0 sq.mm
113Laying the above cable as per IE rules from the between Transformer to rhe panel board
114JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER(Item No.12.2-II /P.No.125/ SOR 2024-25)
115Supply and delivey of pipes and specials including laying and jointing etc complete.
11650 mm GI Pipe
11750 mm GI Coupling
11850 mm GI Bend
11950 mm GI Flange set
12050 mm GI Tee
12150 mm GM Gate valve
12250 mm Non Return valve
12350 mm MS Clamp set
12450 mm GI Hex Nipple
12550 mm GI Flange set rubber Sub Total 619090.5 Paluvoor CWSS
126Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mmdia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capableof discharging noted LPM against head of water column due to all causes. The pump shall bewith stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screwsand CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to acontinous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283/1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ+/- 5 % DUTY OF PUMPSETS
12775 LPM X 60 M - 3.0 HP (Item No.3.1 /P.No.120/ SOR 2025 26)
128Supply and delivery of Star-Delta starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/ 50HZ(+/-5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressedscale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature circuitrbraeker, Thermal Overload relay, Air Break contactors suitable for nextStandard higher KW rating, Single phasing preventor, dry running preventorand On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvcinsulated cable, power capacitor(thecoated vermin proof box, including the cost of capacitor is to be taken separately)
1293 HP (Item No.3.1 /P.No.120/ SOR 2025 26) L.T. CABLES
130PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER (Item No.12.1 /P.No.124/ SOR 2024-25) 4.0 sq.mm
131Laying the above cable as per IE rules from the between Transformer to rhe panel board
132JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER(Item No.12.2-II /P.No.125/ SOR 2024-25)
133Supply and delivey of pipes and specials including laying and jointing etc complete.
13450 mm GI Pipe
13550 mm GI Coupling
13650 mm GI Bend
13750 mm GI Flange set
13850 mm GI Tee
13950 mm GM Gate valve
14050 mm Non Return valve
14150 mm MS Clamp set
14250 mm GI Hex Nipple
14350 mm GI Flange set rubber
144Rate for flushing of borewell of 6” diarequiring less than 4 hours operation usingdrill rods/ hose with required size of pipesfor various capacity compressor includingtransportation, labour, and fuel charges forcompressors as directed by the TWAD Officerand conducting yield test by ‘V’ notch method if required
145600 Cfm ( 100 /150 PSI)
146Rewinding of motor and reconditioning pump and repair works to 2 HP Vertical bore well Pump Set including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset a Head works -2 Nos
147Supply, delivery of PVC insulated and sheathed3 core 4 Sq. mm Copper cable conforming to IS 694/1990 and as amended thereafter for following Wells submersible motor to main panel board.
148Laying the above cable as per IE rules from Transformer to the panel board for laying in trenches inside the pump room or in air
149Jointing the above cable including the cost of jointing materials, lugs, cable clamp etc, complete, confirming to IS 1554 PART I as amended thereafter with ISI marking
150Supply and delivery of the following sizes of PVC pipes confirming to IS specifications including transportation charges any where in Tamilnadu and as directed by TWAD Board officers.
15163mm PVC 4 Ksc
152Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
15363mm PVC 4 Ksc
154Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
15563mm PVC 4 Ksc
156Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
15763mm PVC 4 Ksc Sub Total 433964.8

AI Tender Summary

OUR REF NO 56964071
AUTHORITY Local Bodies
TENDER VALUE 37.81 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name tamil nadu water supply and drainage board
Work Description Tender For Drilling Of New Bore Wells, Flushing Of Existing Bore Wells, Repair And Reconditioning Of Pump Sets For The Following 5 No. Of Cwss In Sivagangai District Under State Drought Relief Fund. (2026-27)
Basic Detail
Tender No 01 FDrought JDORWS SVG 2026 Dt 07 08 2026
Bidding Type Tender
Location
City Sivaganga
State Tamil Nadu
Key Dates
Publish Date 11 Aug 2026
Submission Date 17 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 37.81 Lakhs
Tender Fee Ref. Documents
EMD 20000
Exemption Not Available
Document List
56114366-6a74-4743-8904-0c6612abac2d.html
BidNo01.pdf
BOQ_833634.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

56114366-6a74-4743-8904-0c6612abac2d.html

pdf

BidNo01.pdf

xls

BOQ_833634.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders