Tender For Surveying, Soil Investigation, Engineering, Design, Supply Of All Materials, Labour, T&P Etc. Required For Completion Of Following Works Of Industrial Area Bhooragarh Water Supply Scheme, District Banda Under Deposit Work Programme On Turn
Tender Overview
Project Description
Tender for Surveying, Soil Investigation, Engineering, Design, Supply Of All Materials, Labour, T&P Etc. Required For Completion Of Following Works Of Industrial Area Bhooragarh Water Supply Scheme, District Banda Under Deposit Work Programme On Turn-Key Basis.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | RISINGMAIN |
| 3 | Excavation in foundation in ordinary soil (loam clay or sand) including lift up to 1.50 m & lead up to 50 m refiling ,watering and ramming of excavated earth into the trenches and disposal of surplus earth up to the distance of 50 m from the center of the foundation trenches In ordinary /Kanker Mixed Soil |
| 4 | Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and Rubber gasket of EPDM Quality and including Supply of D.I. S/S or flanged Specials conforming to I.S. 8329/2000 Suitable for above D.I. S/S F.O.R. destination and all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge. |
| 5 | DI Pipe K-9 150MM |
| 6 | Carting ,laying and jointing of the following sizes of pipes induding lowering them into the trenches including the cost of all jointing material labour T&P etc complete |
| 7 | DI Pipe K-9 150MM |
| 8 | Supply of the following sizes of sluice valve /scour valve as per relevent IS code incluiding railway freight and insurance and cartage up to store etc complete. |
| 9 | sluice valve 150mm dia |
| 10 | fixing of following sizes of sluice valve/scour valve incluiding cartage of store to site and lowering in to trench etc complete |
| 11 | sluice valve 150mm dia |
| 12 | Supply of all material labour T&P etc complete for construction of sluice valve chamber as per type & design |
| 13 | Masonry type |
| 14 | Construction of thrust block in bends tees of rising main syestem incluiding supply of all material labour etc complete |
| 15 | Interconnection of rising main pipe from 5.5 MLD WTP's bhooragarh pumping station incluiding supply of specials material labour and filter etc complete |
| 16 | NH Crossing of risinng main incluiding casing pipe and other required specials etc complete |
| 17 | Crossing of big Nala/Culverts incluiding supply of all labour material T&P etc complete |
| 18 | DISTRIBUTION SYESTEM |
| 19 | Excavation in foundation in ordinary soil (loam clay or sand) including lift up to 1.50 m & lead up to 50 m refiling ,watering and ramming of excavated earth into the trenches and disposal of surplus earth up to the distance of 50 m from the center of the foundation trenches In ordinary /Kanker Mixed Soil |
| 20 | 110MM |
| 21 | 140MM |
| 22 | 160MM |
| 23 | Supply of the following sizes of pipes as per relevent IS Code induding Railway freight insurance charges and cartage upto store etc complete-HDPE PN-6 |
| 24 | 110MM |
| 25 | 140MM |
| 26 | 160MM |
| 27 | Carting ,laying and jointing of the following sizes of pipes induding lowering them into the trenches including the cost of all jointing material labour T&P etc complete-HDPE PN-6 |
| 28 | 110MM |
| 29 | 140MM |
| 30 | 160MM |
| 31 | Supply of the following sizes of sluice valve /scour valve as per relevent IS code incluiding railway freight and insurance and cartage up to store etc complete. |
| 32 | Sluice valve/scour valve-100 dia |
| 33 | Fire Hydrant-80mm |
| 34 | Air valve -20mm |
| 35 | fixing of following sizes of sluice valve/scour valve incluiding cartage of store to site and lowering in to trench etc complete |
| 36 | Sluice valve/scour valve-100 dia |
| 37 | Fire Hydrant-80mm |
| 38 | Air valve -20mm |
| 39 | Supply of all material labour T&P etc complete for construction of sluice valve chamber as per type & design masonry type. |
| 40 | sluice valve/scour valve chamber |
| 41 | fire hydrant chamber |
| 42 | air valve chamber |
| 43 | Construction of thrust block in bends tees of rising main syestem incluiding supply of all material labour etc complete |
| 44 | Making stand post for drinking water in industrial area incluiding all material labour and T&P etc complete. |
| 45 | site clearance and other unforseen items |
| 46 | Dismantling of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 47 | BITUMINOUS ROAD |
| 48 | C.C. ROAD |
| 49 | INTERLOCKING TILES |
| 50 | Permanent re-instatement of following type of road surfaces after laying of pipe line including supply of all materials, labour, T&P etc. required for completion of work. It also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning of surface for proper completion of the work as per directions of engineer-in-charge. |
| 51 | Bitumen road TYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cm G -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cm BM (One coat) = 7.5 cmSDBC (One coat) = 2.5 cm |
| 52 | Cement Concrete RoadConstruction of Cement Concrete road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)CC =100 mm, 1:2:4 (cement, coarse sand & stone ballast of 16-20 mm) |
| 53 | C.C. Interlocking Tiles Road Type AConstruction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm) Sand = 50 mm thick local sand lair for preparation of surfaceNote : 100 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road. |
| 54 | OVER HEAD TANK (Existing) |
| 55 | Supply of all material, labour, T&P required for Repairing of Old Existing OHT. Work involved in repair of old OHT are asper following:- 1. Surface Cleaning, sealing of internal & external cracks in concrete structure by epoxy grouting and cement grouting 2. GI hand railing repair including partially replacement of corroded pipes including vertical pipes ends in concrete which are damaged due to corrosion. 3. SS ladder from opening of top dome to bottom dome. 4. Hydro testing of OHT. 5. Cement /Epoxy grouting for water tightness if leackage observed during hrdro testing 6. The food grade epoxy coating of FOSRAC / Ciba-geigy or reputed brand on inside surface area of water container after testing for water tightness. 7. Dismantling and reconstruction of floor, apron, inlet outlet, overflow and washout valve chambers. 8. Replacement of all sluive valves and construction of sluice valve chambers (inlet, outlet and washout). 9. Replacement of damaged CI D/F vertical pipes as required. 10. Replacement of water level indicator and lightening conductor as required 11. Two coat apex ultima painting over one coat primer of approved color after finishing of RCC surface with grinder, reparing of pin holes, unevenness etc. complete required for completion of all works as per direction of Engineer In-charge. |
| 56 | EM WORKS |
| 57 | PUMPING PLANT AND ACCESSORIES FOR CWR |
| 58 | SITC of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 06 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.Capacity as follows :- |
| 59 | 520 LPM / 35 Mtr. HEAD / 7.5 HP MOTOR (1w+1s) |
| 60 | MAIN PIPING :-SITC of 100mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outside the pump house along with 100 x 100 x 100 mm A/F Tee (2 Nos), 100 mm bend (01 Nos), 100 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (03 Nos) etc. complete in all respect as per site conditions. |
| 61 | Sluice valve :- SITC of DI/DF sluice valve without Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 62 | Sluice Valve of size :- 100mm for pumps |
| 63 | Sluice Valve of size :- 100mm for common header |
| 64 | Non return valve :- SITC of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . |
| 65 | 100 mm Dia for pumps |
| 66 | 100 mm Dia for common header |
| 67 | CE/UL Certified Electromagnetic flow meter :- SITC of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 68 | Size 100mm for common header |
| 69 | ELECTRICAL ITEMS:- |
| 70 | Supply & laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 4 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) |
| 71 | MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A, 50KA, TPN, ACB microprocessor baseed (O/C,S/C) release - 1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION32 A, 50KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 4 No, Spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA - 2 Nos. Terminal 63A |
| 72 | SITC of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 7.5 HP / 5.5 KW |
| 73 | SITC of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication ofswitching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 8 KVAR |
| 74 | SITC of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank. |
| 75 | SITC of Servo voltage stabilizer oil cooled having capacity 15 KVA fully copper winding three phase A.C supply 50 Hz. Input voltage 240-450 output voltage 415 volt +/- 1% with earthling wire and power cable |
| 76 | SITC of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 77 | Supply &fixing of Rubber mats for electrical purpose as per IS:5424- 1969, plain/chequered (1mX2m) - 10mm thickness |
| 78 | Cable trench Chequerred plate |
| 79 | Tools |
| 80 | Chain pulley block 3 ton with 4.5 mtr lifting chain |
| 81 | Pressure gauges with all necessary fittings. |
| 82 | 03 Months trial & run except expediture on electricity including operation and chemical charges. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender