Housing Urban and Rular Development Local Bodies Closing in 10 days TDR #56962441

Tender For Village Development (P/L Sewer And Water Line In Village-Shafipur) Noida

Issued by Local Bodies · Ghaziabad, Uttar Pradesh
Tender Value
2.17 Crore
Estimated cost
Bid Submission
25 Aug 2026
10 days left
EMD
5.12 Lakhs
Bank guarantee accepted
Document Fee
5310
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Village Development (P/L Sewer And Water Line In Village-Shafipur) Noida

BOQ

Name of Work:- Village Development (P/L Sewer and Water Line in Village-Shafipur) Noida
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
2Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
3Bituminous portion
4Water bound macadam.
5Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m,disposed earth to be levelled and neatly dressed. .The contractor has to detect different utilities like sewer line,water supply line, electric cable,telephone cable,gas pipe line etc.using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-Charge.
6Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
7a) 1.50 m to 3.00 m
8b) 3.00 m to 4.50 m
9c) 4.50 m to 6.00 m
10Centring and shuttering including strutting, propping etc. and removal of form for Foundation, footings, bases of columns etc. for mass concrete.
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 Cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources )
13Providing & Laying Non Pressure NP-3 class RCC Spigot Socketed pipe confirming to 458:2003 with latest ammendment laying in true alignment & Position on Craddle i/c rubber rings (Confirming to IS :5382 with latestammendmen) testing of laid pipe as per direction of Engineer in Charge complete in all respect.
14a) 400 mm dia NP-3
15a) 300 mm dia NP-3
16a) 250 mm dia NP-3
17Constructing brick masonry circular type manhole 1.52 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
181.52 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
19Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 10.0
20Constructing brick masonry circular type manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
211.22 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
22Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 10.0
23Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
240.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
25Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 100
2612 mm cement plaster of mix 1:4 (1 cement : 4 coarse sand).
27Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test
28as per specifications and having manufactrue's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 c.sand : 6 graded stone agg.20 mm n.s.) complete as per design.
29Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m.
30Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 100mm to 230mm Sewer manhole
31Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
32S/F of M.S. Specials such as Tee, Bends, Collars, Tapers, gap pieces, including Flange Ends as required Painting, Cutting, welding as per site requirement of M.S. pipe thicknwss etc. complete in all respect as per direction of the E/I.
33Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms,depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a leadof 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. Contractor has to detect different utilities like sewer line watrer supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of engineer in charge.
34P/L following size of Finolex makes PVC pipes 6Kg/Cm2 with required PVC standard special confirming to IS codes with latest amendment and lowering the same trenches and laying true to alignment and gradient complete I/c the cost of cutting of pipes for making up to length and making joints i/c cost of socket, plastochem PV-85 pvc solvent cement complete. PVC Pipe must be conferming to IS : 4985-2000 with latest amendment.Make- Finolex Industries Ltd./Kisan/supreme Industries Ltd (Rate As Per comparative Statement per Rm.)(NSI)
35110 mm dia with Coupler @ 6 Kgf/Cm2 Pressure with i/c all PVC standard Specials
36P/L following size of Finolex makes PVC pipes 10Kg/Cm2 with required PVC standard special confirming to IS codes with latest amendment and lowering the same trenches and laying true to alignment and gradient complete I/c the cost of cutting of pipes for making up to length and making joints i/c cost of socket, plastochem PV-85 pvc solvent cement complete. PVC Pipe must be conferming to IS : 4985-2000 with latest amendment.Make- Finolex Industries Ltd./Kisan/supreme Industries Ltd (Rate As Per comparative Statement per Rm.)(NSI)
37160 mm dia with Coupler @ 10 Kgf/Cm2 Pressure with i/c all PVC standard Specials
38200 mm dia with Coupler @ 10 Kgf/Cm2 Pressure with i/c all PVC standard Specials
39P/F Sluice Valve Shall generally-conform to IS 14846 with latest amendment, witg length over flanges as per PD of IS 14846 corresponding to BS EN - 558 / ISO 5752 Basic Series 3. in CI construction having metal seating (1S 318-Gr. LTB 2). with comple Component & Material of construction following below :-1 - Body/ Door/ Dome - Cast Iron JS 210 Gr. FG 260 2 - Spindle - Non rising; Stainless Steel AISI. 410
403 - Body seat/ Door face - Gun metal: IS 318 Gr. LTB 2 (rings to be press fitted and riveted; no screws allowed) 4 - Rivets - Soft annealed brass5 - Spindle Nut - Gun metal: IS 318 Gr. LTB 2 6 - Stem seal - Greased Hemp 7 - Fasteners - Carbon steel8 - Fiangc Drilling - IS 1538 Table 4 & 69 - PN 1.010 - Accessories (400 mm and above) - Ball thrust bearings to be housed above the wet chamber ie. above the gland Enclosed spur gear box for ease pf operation. air plug.
4111 -·Painting/ Coating - Inside & Outside. epoxy liquid coated; DFT minimum 250.micron, shade RAL 5005 /5015 (BLUE) 12 - Hydro-tcst - (Open Ended only) Seat: l O / 1'6 Kg/cm2; Body: 15/24 Kg/cm213 -Upto 600 mm dia . Manual Operated & above 600 mm Gear box Make- Indian Valve Pvt. Ltd. (lVC) / Kirloskar Brothers Limited (KIRLOSKAR)
42a) 100 mm dia Kirloskar make
43b) 200 mm dia Kirloskar make
44Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 10.
45Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 100 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
46Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
47Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Cold twisted bars Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962441
AUTHORITY Local Bodies
TENDER VALUE 2.17 Crore
LAST DATE 25-08-2026
Authority
Authority Name New Okhla Industrial Development Authority
Work Description Tender for Village Development (P/L Sewer And Water Line In Village-Shafipur) Noida
Basic Detail
Tender No 31/SM(JAL)-II/ET/2026-27
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 12 Aug 2026
Submission Date 25 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 2.17 Crore
Tender Fee 5310
EMD 5.12 Lakhs
Exemption Not Available
Document List
15184da3-4575-4246-afd4-59946d7df4a3.html
BOQ_2210470.xls
Cap31.xls
TD31.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

15184da3-4575-4246-afd4-59946d7df4a3.html

xls

BOQ_2210470.xls

xls

Cap31.xls

pdf

TD31.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders