Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #56962408

Tender For Repair/Maint Of External Electric Lt Distribution System At Khanabal Under Ge 861 Ews

Issued by Statutory Bodies & Commissions/Committees · Anantnag, Jammu and Kashmir
Tender Value
17 Lakhs
Estimated cost
Bid Submission
04 Sep 2026
11 days left
EMD
34000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of External Electric Lt Distribution System At Khanabal Under Ge 861 Ews

BOQ

Name of Work:- REPAIR/MAINT OF EXTERNAL ELECTRIC LT DISTRIBUTION SYSTEM AT KHANABAL UNDER GE 861 EWS
Sl. No. Item Description
1Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge.
2Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soil complete all as spefied and as directed by Engineer-in-Charge.
3Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as spefied and as directed by Engineer-in-Charge.
4Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as spefied and as directed by Engineer-in-Charge. (Note:- Punned thickness shall be considered for payment purpose)
5Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
6Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
7Material & Labour for PCC 1:3:6 , Type C2 , using 40mm graded stone aggregates using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
8Dismantling of ACSR or AAC conductors from PCC/ poles complete all as specified and directed by Engineer-in-Charge.
9Dismantling cross-arms of M.S. channel or angle sections etc. complete complete all as specified and directed by Engineer-in-Charge.
10Dismantling insulators any type, any size complete all as specified and as directed by Engineer-in- charge.
11Dismantling steel poles/struts, any size and making good the disturbed area complete all as specified and directed by Engineer-in-Charge.
12Material & Labour in replacement MCCB 4 pole, 63 Amps , 415 volts adjustable type, with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
13Material & Labour in replacement MCCB 4 pole, 100 Amps , 415 volts adjustable type, with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
14Material & Labour in replacement MCCB 4 pole, 160 Amps , 415 volts adjustable type, with breaking capacity 25 KA complete all as specified and directed by Engineer-in-Charge.
15Material & Labour in replacement MCCB 4 pole, 200 Amps , 415 volts adjustable type, with breaking capacity 35/36 KA complete all as specified and directed by Engineer-in-Charge.
16Material & Labour in replacement MCCB 4 pole, 250 Amps , 415 volts adjustable type, with breaking capacity 35/36 KA complete all as specified and directed by Engineer-in-Charge.
17Material & Labour in replacement MCCB 4 pole, 350 Amps , 415 volts adjustable type, with breaking capacity 35/36 KA complete all as specified and directed by Engineer-in-Charge.
18Material & Labour in replacement MCCB 4 pole, 400 Amps , 415 volts adjustable type, with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
19Material & Labour in replacement MCCB 4 pole, 1000 Amps , 415 volts adjustable type, with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
20Supply & Fixing in replacement off load Changeover switch , 415 volts , 50Hz ,TPN , 4 Pole , 63 Amps capacity, enclosed in sheet metal enclosure , floor/ wall mounter complete with handle mechanism, interlocking arrangements, connections , and all accesories compete all as per manufacturer's instructions , compete all as specified and directed by Engineer-in-Charge.
21Supply & Fixing in replacement off load Changeover switch , 415 volts , 50Hz ,TPN , 4 Pole , 100 Amps capacity, enclosed in sheet metal enclosure , floor/ wall mounter complete with handle mechanism, interlocking arrangements, connections , and all accesories compete all as per manufacturer's instructions , compete all as specified and directed by Engineer-in-Charge.
22Supply & Fixing in replacement off load Changeover switch , 415 volts , 50Hz ,TPN , 4 Pole , 200 Amps capacity, enclosed in sheet metal enclosure , floor/ wall mounter complete with handle mechanism, interlocking arrangements, connections , and all accesories compete all as per manufacturer's instructions , compete all as specified and directed by Engineer-in-Charge.
23Supplying and fixing in replacement flat twin core cable of size 6 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and directed by Engineer-in-charge.
24Supplying and fixing in replacement flat twin core cable of size 10 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and directed by Engineer-in-charge.
25Supplying and fixing in replacement flat twin core cable of size 16 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and directed by Engineer-in-charge.
26Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 120.00 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. Notes:(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard.
27Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 150 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. Notes:(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard.
28Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 185 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. Notes:(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard.
29Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 400 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. Notes:(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard.
30Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. Notes:(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard.
31Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. Notes:(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard.
32Material & Labour in replacement cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 120 Sqmm to 185 Sqmm 3.5 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed by Engineer in Charge
33Material & Labour for in replacement cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 240 Sqmm to 300 Sqmm 3.5 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed by Engineer in Charge
34Material and Labour for painting of LT steel tubular elect pole with cross arms angle etc with scrubbing the old surface with emergy paper to remove old paint and applying one coat of primer and two coat silver color water proof enamel paint complete all as specified and directed by Engineer-in-Charge.
35Supply and Laying / Fixing in replacement GI tubing 80mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'BoQ.
36Supply and Laying/ Fixing in replacement GI tubing 40mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'BoQ.
37Supply & Fixing in replacement street light junction/ pole box of size 250mm x 200mm x 150 mm made of MS sheet 1.6 mm thick front openable with fixing screw painted with two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer with and including two nos. aluminium bus bar of 20mm x 3 mm mounted on epoxy based post insulator and drilled holes for cable connection with and including one No. MCB SP 6 Amps 'C' Curve,10 KA and fixing on steel tubular pole with MS strip of size 20mm x 3 mm with suitable size nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge.
38Supply & Fixing in replacement Security light brackets of 40mm bore GI pipe Light grade 1.2 mtr long bend to shape at 100-120 degree including and fixing at pole/ wall/ angle with the help of flat iron clamps and suitable nuts and bolts including all material required for fitting , including matching the surface with existing all complete all as specified and directed by Engineer-in-Charge.
39Supply & Fixing in replacement of galvanised strip 32mm x 6 mm with fixing arrangements etc complete all as specified and directed by Engineer-in-Charge.
40Supply & Fixing in replacement LED Security flood light fitting 70 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
41Supply & Fixing in replacement LED Security street light fitting 36 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
42Material and Labour for in replacement Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
43Material and Labour and tools as required for repair of broken out old LT panels steel doors by cutting of damaged/ misaligned old hinges and welding of new suitable size hinges as required and repair/ replacement of door holding clits as required to re-fixing door, proper alignment for smooth working i.e opening and closing complete all as specified and directed by Engineer-in-charge.
44Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962408
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 17 Lakhs
LAST DATE 04-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of External Electric Lt Distribution System At Khanabal Under Ge 861 Ews
Basic Detail
Tender No GE 861 EWS-46(T)/2026-27
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 11 Aug 2026
Submission Date 04 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 17 Lakhs
Tender Fee 500
EMD 34000
Exemption Not Available
Document List
8f421b64-651c-4547-9350-c8070af9b458.html
BOQ_878334.xls
Credit46T.pdf
Tender46T.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

8f421b64-651c-4547-9350-c8070af9b458.html

xls

BOQ_878334.xls

pdf

Credit46T.pdf

pdf

Tender46T.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders