Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56962388

Tender For Repair/ Maintenance Of Lightning Protection System And All Type Of Earthing Under Ge Gomantak Vasco

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
40 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
10 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Lightning Protection System And All Type Of Earthing Under Ge Gomantak Vasco

BOQ

Name of Work:- Repair/ Maintenance of lightning protection system and all type of earthing under GE Gomantak Vasco
Sl. No. Item Description
1M&L for taking down existing earthing and providing new chemical earthing, electrode made of copper molecular bonded steel rod 17.2 x 3000 mm, minimum 254 micron coating, with connecting strip head with SS fastener, inspection joint box and also connect copper strip with electrode rod and inspection joint box with nut, bolts and GI washers etc. The electrodes will be filled with highly conductive non-corrosive crystalline conductive mixture with connective arrangement for connection of strip/cable etc. The electrode will be installed along with conductive and low resistance powder tested to the resistivity of 0.2 ohms as per IEC 62561-7 read with ASTM G57-06, CI 3.4 connected to copper strip by means of nut, bolts, check nuts and washer of GI or steel including necessary drilling in earth upto 3 mtr in any type of soil for inserting electrode in any type of strata, Heavy duty poly plastic chamber with cover complete all as specified and directed.
2S&F in replacement 20 x 3 mm copper strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
3M&L for fixing in replacement test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hexagonal head screw and including provision of suitable MS box made out of 3 mm thick MS sheet to accommodate the terminal block complete all as specified and directed.
4M&L for GI tubing light grade 40 mm bore for passing copper strip laid under the floor, along the wall or along the pole incl taking out/down existing pipe complete all as specified and directed .
5M&L for PCC 1:3:6 type C-1(using 20 mm graded stone aggregate) as in repair of exisitng plinth protection including necessary formwork complete all as specified and directed.
6S&F in replacement aluminium strip 25 x 3 mm fix on porcelain insulator for roof conductors and down conductors above ground level as lighting conductor (including insulator) complete all as required at site and as directed.
7S&F in replacement Air termination, single pointed Copper Rod 12mm dia and 300 mm long complete all as specified and directed.
8Supply and filling of chemical earthing compound for enhancement of grouding in existing earthpit complete all as specified and directed.
9M&L for taking down existing earthing and providing new earthing complete with copper plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to copper earth strip 25 x 3 mm by means of bolts, nuts check nuts and washers of brass connected to earthing test point all as specified incl 25 mm GI tubing medium grade and necessary fitting for protection of GI wire, laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 15 mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 5 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth strip and earh strip upto 7.5 M.
10S&F in replacement HDPE earth pit cover of 12 inch dia conical shape including removal of old one and fixing the new one with PCC complete all as specified and directed.
11M&L for taking down existing earthing and providing new earthing complete with galvanised steel plate electrode 600 mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and earth strip upto 7.5 M.
12S&F in replacement MCCB 160 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed.
13S&F in replacement MCCB 250 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed.
14S&F in replacement MCCB 400 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed.
15Supply and fixing in replacement of existing old un-serviceable Earth continuity conductor of size 25 x 4 mm GI strip fixed to wall and batton or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. complete all as specified and directed.
16S&F in replacement LED flood light fitting 120 Watts, IP 66, having pressure die cast aluminium alloy housing with high power LED as lightning source and lens embedded PC cover having top opening seperately including Driver having IP-66 protection and making electrical connection to the fitting with Suitable size of service wire complete as as directed.Make- Crompton CRP-504-120-57-60D-SL-GL-NSG/ Havells Cat no: JETALEGANZAFLS120WLED757P60DTOTG/ Bajaj PRAZE F 168L WH NB-A5 TG SD Note :- Connection cable will be measured and paid seperately under respective item
17S&F in replacement LED flood light fitting 200/210 Watts, IP 66, having pressure die cast aluminium alloy housing with high power LED as lightning source and lens embedded PC cover having top opening seperately including Driver having IP-66 protection and making electrical connection to the fitting with Suitable size of service wire complete as as directed.Make- Crompton LFLN-200-CDL/60-M/ Havells Cat no: JETALEGANZAFLS200WLED757P60DTOTG/ Bajaj PRAZE F 280L WH NB-A5 TG SD Note :- Connection cable will be measured and paid seperately under respective item
18S&F in repair 4 Pole Power Contactor suitable for operation on 415V, 3 Phase, 50Hz AC supply, AC-3 duty, 325 Amp conforming to IS/IEC 60947-4-1, complete with 230V AC operating coil, minimum 2 NO and 2 NC auxiliary contacts including all necessary accessories, connections, testing and commissioning, complete all as specified and directed
19S&F in repair 4 Pole Power Contactor suitable for operation on 415V, 3 Phase, 50Hz AC supply, AC-3 duty, 160 Amp conforming to IS/IEC 60947-4-1, complete with 230V AC operating coil, minimum 2 NO and 2 NC auxiliary contacts including all necessary accessories, connections, testing and commissioning, complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962388
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Lightning Protection System And All Type Of Earthing Under Ge Gomantak Vasco
Basic Detail
Tender No 8831/E8
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 11 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_878271.xls
d98f5548-ef69-490c-9828-21e7e9c178fd.html
tender8831.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_878271.xls

html

d98f5548-ef69-490c-9828-21e7e9c178fd.html

pdf

tender8831.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders