Tender For Provision Of External E/M Services For Containerised Small Arms Firing Range At installation Mandovi
Tender Value
40 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
18 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of External E/M Services For Containerised Small Arms Firing Range At installation Mandovi
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing & commissioning of 4 way RMU 11KV, 630A, 21kA/1 sec, Both Side Extensible, Motorised, Outdoor Type, SF6 insulated circuit breaker at all 4 ways (both incoming and out going ),(V-V-V -V type ) , IP-64 for enclosure and IP 67 for SF6 Tank, SF6 Gas Insulated Ring Main Unit with 4 way with Air Insulated Bus PT Panel11 KV,inside manually welded stainless steel (Non Ferrite Non Magnetic Grade) tank having minimum thickness 2.5 mm having IP 43 Degree of Protection. RMU should be provided with Copper bus Bar, Minimum 2 core Resin cast ring core protection CT at all incoming and Out going having 50 - 25 /5-5/(5-1) Amp, with suitable accuracy level and VA rating as for Measuring Instruments and PT with 11/KV/110 Volt with suitable VA and accuracy standard complete with padlock provision and with all accessories. |
| 2 | Note: Rate Quoted by the contractor for this item should include the cost of the following:- (i) PCC work/ any civil work for foundation required for errection of RMU and other accessories all as standard norns.(ii) Protection scheme with o/C and E/F relay in all incoming and Outgoing with display and self powered digital relay covering along with auxiliary power relay, Master trip relay for RMU complete. (iii) All the incoming and outgoing cable end joints shall be with right angle boots at incoming and outgoing cable connections. (iv) All the incoming and Outgoing ways are marked with feeding location by using proper sticker and danger notice board 11 KV pasted on Switch gear . |
| 3 | Supply, install, testing and commissioning of Distribution transformer (Level - 2, maximum total loss at 50% load 670Watts and 100% loss 2100 Watts) 200 KVA, 11KV/.0.433KV, Three Phase complying with IS: 1180 (Part-I) 2014 with latest amendments, mounted on masonry platform step-down, Outdoor type double copper wound suitable for 50 Hz system of capacity not less than oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge and installation of transformer shall be carried out as per IS-10028 and comprising with the following standard fittings/ Technical specification. Please Enable Macros to View BoQ information |
| 4 | Supply, install, testing and commissioning of Distribution transformer (Level - 2, maximum total loss at 50% load 670Watts and 100% loss 2100 Watts) 200 KVA, 11KV/.0.433KV, Three Phase complying with IS: 1180 (Part-I) 2014 with latest amendments, mounted on masonry platform step-down, Outdoor type double copper wound suitable for 50 Hz system of capacity not less than oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge and installation of transformer shall be carried out as per IS-10028 and comprising with the following standard fittings/ Technical specification. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender