Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56962382

Tender For Certain Repair Of Chloronome Plants, Ro, Dg Sets, Cleaning Of Drinking Water, Ug Sumps, Over Head Tanks And Repair To Water Level Indicator, Primeing System, Lightening Protection, Earthing Pits And Misc Works In The Area Of Age(U) W/S No-

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
44 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
18 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Certain Repair Of Chloronome Plants, Ro, Dg Sets, Cleaning Of Drinking Water, Ug Sumps, Over Head Tanks And Repair To Water Level Indicator, Primeing System, Lightening Protection, Earthing Pits And Misc Works In The Area Of Age(U) W/S No-Ii Under Ge (U) Water Supply Delhi Cantt-10

BOQ

Name of Work:- CERTAIN REPAIR OF CHLORONOME PLANTS, RO, DG SETS, CLEANING OF DRINKING WATER, UG SUMPS, OVER HEAD TANKS AND REPAIR TO WATER LEVEL INDICATOR, PRIMEING SYSTEM, LIGHTENING PROTECTION, EARTHING PITS AND MISC WORKS IN THE AREA OF AGE(U) W/S NO-II UNDER GE (U) WATER SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Preventive maintenance of electric motor driven Chlorine dosing system any make including cleaning of electrode rod, HDPE/FRP tank of capacity up to 150 Ltr tank and checking functioality and performance of level gauge, dosing pump, High pressure single head gear motor ,pressure gauge, power pack incl oiling and greasing of all moving parts under GE(U) Water supply Delhi Cantt.Note :Spare parts reqd for replacement in maintenance work will be measured & paid seprately.
2Opening the motor of capacity 0.5HP, rewinding the motor with super enammeled copper wire of existing gauge, weight etc, reparing the same by replacing the unserviceable spare parts and re-assembling the motor in orignal position to make it functional complete all as specified and as directed.
3Supply only of gear motor 230 volt 50 Hz suitable for decrin dosing pump Part No PM 682 CE
4Supply only of Rotor assembly with bearing brackets and tolerance rings. Part No PMBR PL2
5Supply only of Coil 250 volt, 50Hz Part No. MP 6 J222
6Supply only of Single head feed rate control with shaft Part No FC 5040D
7Supply only of Pump head (Ferrules 1/4\\" including duckbill Part No UCPH 7 FD
8Supply only of Roller assembly Part No. MC3ASYD
9Supply only of Pump tube Part No MCCP 207
10Supply only of Injection check valve 3/8\\" Part No MCINJ 38
11Supply only of Weighted suction line strainer 3/8\\" Part No. ST 138
12Supply only of White suction/discharge tube Part No. MAL T002
13Supply only of chloroscope for water testing range of 0.1 ppm to 2.0 ppm
14Supply only of ORTO-TOLUDINE regent solution in 500 ml bottle
15Supply only of first Aid kit (PVC container) as per the specification including first aid medical treatment materials complete.(Note : All the medicine and First Aid will be of latest date and should be having atlest 12 months expiry date from the date of actual supply)
16Supply only Knob of speed/stroke complete all as specified and directed.
17Supply only main indicator lamp assembly complete all as specified and directed.
18Supply only valve seat cap of suction/discharge complete all as specified and as directed
19Supply only fixing bolts made of stainless steel or supplied by OEM only
20Supply only main indicator lamp assembly
21Supply only Diaphragm seal
22Supply only Diaphragm
23Supply only Shaft(Diaphragm)
24Supply only strainer only(Foot valve)
25Supply only Pipe(Discharge/suction)
26Supply only Foot valve assembly (complete with ball,seal &spring)
27Supply only pulser circuits & speed potentiometer
28Supply only power transformer.
29Supply only fuse assembly including fuse complete all as specified and directed.
30Supply and fixing in replacement of 2.5 sqm 3 core flexible cable suitable for 15 Amp 3 pin plug top. (As per present sample)
31Supply and fixing in replacement of antisyphon valves (comlete with ball, seal & Spring) complete all as specified and directed.
32Supply and fixing in replacement of FRP tank of capacity 100 Ltrs as per existing sample only
33Supply and fixing in replacement of FRP tank of capacity 150 Ltrs as per existing sample
34Supply and fixing in replacement of 15 Amp 3 pin plug top
35Supply and fixing in replacement of FRP construction solution preparations cum settling Tank with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator of capacity 100 Ltr complete all as specified and directed.
36Supply and fixing in replacement ofFRP construction solution preparations cum settling Tank with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator of capacity 150 Ltr complete all as specified and directed.
37Supply only of PVC/rubber Hand glove suitable for handling of liquid Chlorine ISI marked complete all as specified and directed.
38Material & Labour for comprehensive mentainance including all consumable chemicals (Pelican-319/ or As suitable for the RO plant at site) etc. of Reverse Osmosis Plant of 1 x 100 LPH, 1 x 500 LPH and 1 x 1000 LPH capacity installed in the AOR of GE (U) Water Supply AOR comprising of the following items:-(a to y)
39(a) Raw water feed/Backwash/CIP Pump with SS 304 impeller (CNP/Eqvt standard make) of capacity 6 Meter cube/Hour at 3 Kg/centimeter squared pressure - 03 Nos
40(b) FRP dual media filter of size 30\\" x 72\\" or suitable at site for the respective model of RO - 02 Nos
41(c) Anti scalant dozing system (i) HDPE dozing tank of capacity 100 lts - 02 Nos (ii) Dozing pump 0.5 LPH, PP or eqvt - 01 No
42(d) Micron Cartridge filter suitable for 6 cubic meter/hour for micron filter with PVC housing (Gopani), PP Cartridges - 01 lot
43(e) High Pressure pump of 6 cubic meter/hour at 14.5 kg/centrimeter squared pressure, SS -304 Impeller vertical centrifugal type (CNP or equivalent) - 02 Nos
44(f) TFC (CPA2-8040) RO Membrane of size 8\\" x 3 Nos - 01 Lot
45(g) FRP RO Pressure tube 8\\" , 3 Elements long, 250 PSI - 01 Nos
46(h) HDPE pH dozing tank of capacity 100 ltrs - 02 Nos
47(j) pH Dozing pump 0.5 LPH, PP or equivalent - 02 Nos
48(k) MSEP Skld - 02 Nos
49(l) MSPC Control Panel - 01 Nos
50(m) HDPE CIP Tank capacity - 500 ltr - 01 Nos
51(n) CIP micron cartridge filter of suitable size with PP/PVC housing, PP Cartridges - 01 lot
52(o) SS Solenoid Valve - 01 No
53(p) UPVC low pressure piping - 01 lot
54(q) Flow indicator - 01 lot
55(r) Pressure guage - 01 lot
56(s) Pressure switch low and high - 02 Nos
57(t) Conductivity indicator - 01 Nos
58(u) Level switch - 01 Nos
59(v) 5 micron cartridge filter suitable for 6 cubic meter/hr frol with PVC housing (Gopani), PP Catridges
60(w) CIP micron cartridges filter of suitable size with PP/PVC housing, PP cartridges
61(x) Sodium bicarbonate for pH control - As required basis
62(y) Antiscalent liquid
63Note : (A) RO Plant of above mentioned capacities runs for 08 hours including all items taken in item Ser No 39 should be capable to work on the following water characteristics of inlet water :- (i) Total Hardness > 200 mg/ltr (ii) Chloride (as Cl) > 200 mg/ltr, TDS > 300 mg/ltr (iv) pH above 7.7, (v) iron > 0.22 mg/ltr (vi) Fluoride (as F) content > 0.44 mg/ltr. (B) Treated water characterisctic at the outlet of the RO plant must be : (i) TDS < 140 ppm (mg/ltr) (ii) Total Hardness , 25 ppm (mg/ltr) (iii) pH value - NEUTRAL.
64Test sampling of drinking water being collected from RO outlet and RO inlet (Raw water) and submission of detailed test report from NABL accreditated Laboratory to GE/Engr-in-Charge fortnightly. (a) Collection of water sample from Pump House in presence of Engr-in-Charge/JE assigned the task, in Starlized bottles and testing in Govt approved lab as mentioned in specification. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for presence of any Chemical, colour, odour, Taste, turbidity, pH Value, TDS, Total Hardness, Iron, Chloride, Fluoride, residual free Chlorine and bacteriological collie form from micro-organism per 100 ml (MPN) and to this office with specific recommendation regarding suitability of water for drinking purposes.NOTE:- Rate quoted shall deemed to be included for :- (i) Cost of Sterilized Bottles as required and (ii) To and fro transportation charges for collection of samples from sources.
65M&L for Periodical mainteneance of DG Set capacity 250 KVA Make- kirloskar , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Cummins installed at Arjan vihar pump house complete all as specified and directed by Engr-in-charge .(Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
66Supply and fixing in replacement of the following items of DG Sets 250 KVA Make- kirloskar , Model- installed at Arjan vihar pump house including taking out existing unserviceable items:-
67Fan belt as per sample
68V Belt, as per sample
69Lub oil filter as per sample
70Fuel filter element as per sample
71By pass oil filter as per sample
72Air cleaner, inner element and outer set as per sample
73M&L for Periodical mainteneance of DG Set capacity 160 KVA Make- Cotton Greaves, by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Cummins installed at Harbux stadium & cavillary Hill complete all as specified and directed by Engr-in-charge .(Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
74Supply and fixing in replacement of the following items of DG Sets 160 KVA Make- Cotton Greaves , Model- installed at Harbux stadium & cavillary Hill including taking out existing unserviceable items:-
75Fan belt as per sample
76V Belt, as per sample
77Lub oil filter as per sample
78Fuel filter element as per sample
79By pass oil filter as per sample
80Air cleaner, inner element and outer set as per sample
81M&L for Periodical mainteneance of DG Set capacity 125 KVA Make- kirloskar, cummins & Mahidra & Mahindra , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- kirloskar, cummins & Mahidra & Mahindra installed at DK part -I pump House, Parade Road Pump House complete all as specified and directed by Engr-in-charge.(Note :- Fuel filter, Lub oil filter, by pass filter, air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
82Supply and fixing in replacement of the following items of DG Sets 125 KVA Make- kirloskar, cummins & Mahidra & Mahindra , Model- installed at DK part -I pump House, Parade Road Pump House including taking out existing unserviceable items: -
83Fan belt as per sample
84V Belt, as per sample
85Lub oil filter as per sample
86Fuel filter element as per sample
87By pass oil filter as per sample
88Air cleaner, inner element and outer set as per sample
89M&L for Periodical mainteneance of DG Set capacity 100 KVA Make-Kirloskar/Ashoke Leyland/Cotton Greaves , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Kirloskar /Ashok Leyland/cotton Greaves at STP Baird Place, RRRC Pump House, Sanjay Vihar P/H , Kabul line P/H, Arjan Vihar STP,OPC Pump House & Kabul Line pump House different location of STPs & Pump Houses, complete all as specified and directed by Engr-in-charge .(Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
90Supply only following items of capacity 100 KVA Make- Kirloskar (Sanjay Vihar P/H & Kabul line P/H)/Ashok Leyland (STP Baird Place & RRRC P/H) and taking out the existing unserviceable items:-
91Supply and fixing in replacement of the following items of DG Sets 100 KVA Make- Kirloskar/Ashoke Leyland/Cotton Greaves Model- installed at STP Baird Place, RRRC Pump House, Sanjay Vihar P/H, Kabul line P/H, Arjan Vihar STP,OPC Pump House & Kabul Line pump House different location of STPs & Pump Houses, including taking out existing unserviceable items: -
92Fan belt as per sample
93V Belt, as per sample
94Lub oil filter as per sample
95Fuel filter element as per sample
96By pass oil filter as per sample
97Air cleaner, inner element and outer set as per sample
98M&L for Periodical mainteneance of DG Set capacity 90KVA Make-Kirloskar/Bosch , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Kirloskar/Bosch (Urban Village P/H and Manekshaw Centre P/H) different location of STPs & Pump Houses, complete all as specified and directed by Engr-in-charge .(Note :- Fuel filter, Lub oil filter, by pass filter, air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
99Supply and fixing in replacement of following items of capacity 90 KVA Make- Kirloskar (Urban Village P/H & Manekshaw centre P/H) and taking out the existing unserviceable items:-
100Fan belt as per sample
101V Belt, as per sample
102Lub oil filter as per sample
103Fuel filter element as per sample
104By pass oil filter as per sample
105Air cleaner, inner element and outer set as per sample
106M&L for Periodical mainteneance of DG Set capacity 75 KVA Make-Kirloskar, by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Kirloskar (STP Cariappa Vihar) at different location of STPs & Pump Houses, complete all as specified and directed by Engr-in-charge .(Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
107Supply and fixing in replacement of following items of capacity 75 KVA Make- Kirloskar (STP Cariappa vihar) and taking out the existing unserviceable items:-
108Fan belt as per sample
109V Belt, as per sample
110Lub oil filter as per sample
111Fuel filter element as per sample
112By pass oil filter as per sample
113Air cleaner, inner element and outer set as per sample
114M&L for Periodical mainteneance of DG Set capacity 63 KVA Make-Kirloskar, by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Kirloskar (STP Kabul Lines and STP DK Part I) or at different location of STPs & Pump Houses, complete all as specified and directed by Engr-in-charge (Note :- Fuel filter, Lub oil filter, by pass filter, air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
115Supply and fixing in replacement of following items of capacity 63 KVA Make- Kirloskar (STP Kabul line &STP DK Part-1)and taking out the existing unserviceable items:-
116Fan belt as per sample
117V Belt, as per sample
118Lub oil filter as per sample
119Fuel filter element as per sample
120By pass oil filter as per sample
121M&L for Periodical mainteneance of DG Set capacity upto 50 KVA Make-Grives Cotton/mahindra/kirloskar (loc -Church Road,sanyat line,APS Colony,28 punjan STP& Engr Regt) by replacing fuel filter , Lub oil filte, by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Grives Cotton/mahindra/kirloskar (loc -Church Road,sanyat line,APS Colony,28 punjan STP& Engr Regt) or at different location of STPs & Pump Houses, complete all as specified and directed by Engr-in-charge .(Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
122M&L in replacement of following items of capacity upto 50 KVA Make-Grives Cotton/mahindra/kirloskar (loc -Church Road,sanyat line,APS Colony,28 punjan STP& Engr Regt) and taking out the existing unserviceable items:-
123Fan belt as per exsting at site
124V Belt, as per exsting at site
125Lub oil filter as per exsting at site
126Fuel filter element as per exsting at site
127By pass oil filter as per exsting at site
128Air cleaner, inner element and outer set as per exsting at site
129M/L in replacement of AVR as per exsting at site
130M&L in replacement of Shut down Valve 24 volts as per exsting at site
131M&L in replacement of Battery Charging alternator with inbuilt regulator as per exsting at site
132M&L in replacement of Turbo charger reapair Kit as per exsting at site
133M&L in replacement of RPM cum hour meter as per exsting at site .
134M&L in replacement of Lub oil pump as per exsting at site
135M&L in replacement of heavy duty brass thimble for battery
136M&L in replacement of Solonoid valve as per exsting at site
137M&L in replacement of Flexible fuel pipe as per exsting at site
138M&L in replacement of Set of gasket
139M&L in replacement of High pressure pipe as per exsting at site
140M&L in replacement of radiator hose pipe as per exsting at site
141M&L in replacement of Air cleaner, inner element and outer set as per exsting at site
142M&L Dismantling the alternator assembly of DG set of capacity up to 250 KVA from the foundation after disconnecting the electric connection,carrying the same to workshop,dismantling of alternator and taking down worn out windings of rotor field coils and excitor coils,rewinding the stator,rotor and excitor gauge, replacement of insulation material,heat varnishing provision of connecting leads and terminal plates etc to make the alternator fully serviceable,reassembling the alternator shifting back to the installation ,assembling the same with engine making electric connections,testing and commissioning complete all as specified and directed by Engineer-in-Charge.
143M&L as in Repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts and testing by celebration as per sample of cap 15 KVA to 63 K VA.
144M&L as in Reapir of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts and testing by celebration as per sample of cap 75 KVA to 100 KVA.
145M&L as in Repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug , nozzle etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts and testing by celebration as per sample of cap 125 KVA to 250 KVA.
146M&L as in Repair to self starter with replacement of carbon brushes,pinion,rewinding of starter and rotor winding, replacement of defective bents etc to make the starter fully serviceable and testing for DG Set any make any size.
147M&L as in Repairs to radiator assembly Cleaning washing thoroughly with LIQUI MOLY Radiator Cleaner de- scaling incl M&L for replacement of rubberize parts and MS Nut & Bolts including brazing /repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling any type any capacity complete all as specified and directed by EIC.
148M&L as in Repairs to DG Set of capacity 15-90 KVA control panel any type incl replacement defective sensors like AMF module , relay card / board ,current transformer ,key switch , indiators , warning ,push button and checking wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge
149M&L as in Repairs to DG Set of capacity 100-250 KVA control panel any type incl replacement defective sensors like AMF module , relay card / board ,current transformer ,key switch , indiators , warning ,push button and checking wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge
150M&L in replacement of Dynamo segregation of all parts supply and fix replacement of armature field, coil, carbon brush and bearing etc reassembling and testing.
151Supply and fixing in replacement of rotating rectifier diode set (forward - 3 nos & reverse - 3 nos) along with surge arrestors suitable for the following DG set of make: CUMMINS/Kirloskar/Ashok Leyland fixing and connecting in the circuit, starting and testing on load all as specified and directed by Engineer-in-charge
152For Alternator of Capacity 100 KVA to 250 KVA
153For Alternator of Capacity 15 KVA to 90 KVA
154M&L in replacement of Electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs
155M&L in replacement Automatic Float cum Boost Charger 12V/10-15A with protection Fuse and LED indications
156M&L in replacement Automatic Float cum Boost Charger 24V/15-25A with protection Fuse and LED indications
157M&L in replacement ACB Shunt release /tripping coil of110V/240V
158M&L in replacement ACB Closing coll of 110V/240V
159M&L in replacement Auxilary control Contactors /relays with Add On's
160M&L in replacement power contactors Coils operatable at 110V/230V/440V 50Hz Supply
161Power Contactor Coil For 250-160 KVA Alternator AMF
162Power Contactor Coil For 125-15 KVA Alternator AMF
163Supply and fixing in replacement of control panel suitable for DG set upto 250 KVA
164Disconnecting and taking down unserviceable battery terminal and S&F in replacement of battery terminal brass heavy duty.complete suitable for fixing on battery poles with nuts and bolts complete all as specified and directed.
165M&L in replacement of Jumper Cable with crocodile type strong grip clamps securily crimped on both ends and suitable to carry high current 4 Gauge x 20 Ft 500 A Heavy duty with travel Bag and Safety Gloves (4 AWG x 20 Ft)
166Reapirs/ servicing to the stop Solinoid coil of capavity 12/24 Volt connected to the DG set of varoius capacity 200 to 15 KVA / any Makes as per existing at site including replacement of defective pars including winding complete all as specified and directed.
167M&L for to carry out repairs to self starter by replcement of defective armature , field coils carbon brushes, soliniod, bearings reassembling the same and testing complete suitable for 24 volts/12 volts operation all as specified and directed
168M&L in replacement of for to carry out repairs to 12/24Volt Alternator / dynamo by replacement of carbon brush, electronic regulator / rectifier, bearings reassembling the same and testing complete all as specified and directed.
169M&L in replacement of Coolant Tempetarure Sensor suitable for 250-15 KVA Cummins/Kirloskar/Ashok Leyland/mahindra DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
170M&L in repair of old hinges and fixing new with fitting/welding as per existing size complete all as specified and as directed
171M&L in replacement of rusted MS sheet at any portion of canopy and supply and fixing new sheet of 14 gauge with fitting/ welding and painting complete as erquired.
172Material and Labour for complete fixing in repairs for DG set accoustic enclosure door Hinges /Aldrops/ locks with keys -02 sets including carring out necessary repirs/modifications complete all as specified and directed
173Taking out and replacement of unservicable/blocked/rusted MS pipe heavey duty 3” dia.(NB) duly ISI marked , including thermal insulation with 50 mm thick glass wool of 48 kg .per cubic meter denisity, chiken wire mesh and cladding with 24 gauge aluminium sheet for exhaust of smoke of DG set including fixing the cladded pipe on MS support structure on the wall / celling including cutting, welding etc complete all as specified and directed.
174M&L in replacement old unserviciable maintanance Free Heavy duty Battery suitable for DG set of following.
17512V 180AH with 36 Months min warranty after necessary approval from Engr in charge
17612V 160AH with 36 Months min warranty after necessary approval from Engr in charge
17712V 100 AH with 36 Months min warranty after necessary approval from Engr in charge
178Taking down of the defective change over switch of the DG sets and Supply in replacement as per existing onload change over switch with auxilary contacts operatable at 440 V, 50Hz supply with enlosure operatable handle, 4 pole 200 Amp
179M/L repair of test point terminal block made of steel plate of size 75x75x6 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex. head screw complete all as specified and directed by EIC.
180M&L in replacement aluminum strip 25x3.15mm as roof conductor or down conductor or along the pole/pipe complete with saddles/ insulators made out of porcelain or fibere and fixing screws all as required at site or directed.
181M&L for Cleaning of semi under ground sumps storage capacity of water 3 lac gallons throughly by removing mud, grits incl 02 coat of white wash inside on conceret surface and out side 2 coat of appex paint after scraping old one complete all as specified and as directed.Loc : CV Hill Pump House
182M&L for Cleaning of semi under ground sumps storage capacity of water 1.75 lac gallons throughly by removing mud, grits incl 02 coat of white wash inside on conceret surface and out side 2 coat of appex paint after scraping old one complete all as specified and as directed.Loc : Carrippa Viahr and Moude road Pump House
183M&L for Cleaning of semi under ground/ under ground sumps storage capacity of water 0.25 lac to 1.00 lacs gallons throughly by removing mud, grits incl 02 coat of white wash inside on conceret surface and out side 2 coat of appex paint after scraping old one complete all as specified and as directed.Loc :RCCC,LORRY ROAD , DKPART-I, AEPTA, SANJAY VIHAR , APS COLONY ,PARADE ROAD , URBAN VILLAGE ,MANKSHAW ENCLAVE , CHURHCH ROAD , HARBUX STADIUM, OPC , NPC , BAIRD PLACE , MANKSHAW CENTER , ARJAN VIHAR , NEW KABUL LINE , OLD KABUL LINE , SANYAT LINE , SUMRAN LINE, DGNCC, TIGRIS ROAD PUMP HOUSENotes for srl Item Nos 102 to 104 :- Rates quoted shall deemed to includes for (i) Cleaning inner surfaces of tank complete by scrapping with steel wire brushes, pressure wash, removing mud, sludge collected inside the tank manually to a distance not exceeding 50 Mtrs.(ii) Washing with clean water & bleaching powder or with high strength calcium chloride mixture thoroughly internally, removing leftout sludge, if any, to a distance not exceeding 50 Mtrs including writing capacity of sump, cleaning date & due date of cleaning with black synthetic enamel paint complete as per existing pattern.
184Supplying, fixing, jointing and testing in replacement of cast iron foot valve 100 mm bore , flanged ends pressure rating PN-0.2 operation with rubber sheet, swing type, confirming to IS- 4038 complete including taking out unserviceable foot valve complete all as specified and as directed .
185Supplying, fixing, jointing and testing in replacement of cast iron foot valve 150 mm bore , flanged ends pressure rating PN-0.2 operation with rubber sheet, swing type, confirming to IS- 4038 complete including taking out unserviceable foot valve complete all as specified and as directed .
186Opening of existing foot valve, of any make/ location, 100 mm to 300 mm bore, from UG sump, pump suction line for repairing/ servicing such as cleaning with & including replacement of foot valve sheet, nuts,bolts & washers etc as required and reassembling/ refixing at desired locations to make it functional complete all as specified and as directed .
187Supply and fixing in replacement of mild steel work for manhole cover, stair case steps etc made of MS angle/ flats/channels of any size as required at site etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers, steps etc complete all as specified and as directed.
188Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed.
189Taking down carefully sub main wiring/Service cable of any description.
190Disconnecting elect connection and taking down of ceiling fan / Exaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified.
191Taking down defective switch fuse main board / distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed.
192M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
193One light controlled by one, one way switch .
194Ceiling fan/exhaust fan point controlled by one, one way switch .
195One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
196One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
197All as per item No.115 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 115 & 117 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
198M&L in replacement of switch Piano type 6 Amps 230V AC complete all as specified and directed.
199M&L in replacement of Piano socket outlet 5 pin 6 Amp socket 2 module complete all as specified and directed.
200M&L in replacement of switch Piano type 16 Amps 230V AC complete all as specified and directed.
201M&L in replacement of Piano socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed.
202Supply and fix in replacement of LED batten luminaire surface mounted, 4 feet system wattage of 20Watts including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
203Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection complete.
204Material and labour Rewinding of ceiling fan 1200/1400 mm swipe with suitable gauge of enamelled copper wire complete and including with suitable class of insulating varnish including winding materials, attending lathe work to fan rotor shaft and including painting of ceiling fan with two coats of synthetic enamel paint and writing MES numbers complete all as directed..
205Material and labour Rewinding of Ventilating Fan 450 mm sweep with suitable gauge of enamelled copper wire complete and including with suitable class of insulating varnish including winding materials, attending lathe work to fan rotor shaft and including painting of ceiling fan with two coats of synthetic enamel paint and writing MES numbers complete all as directed..
206S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed.
207S&F MCB SPN upto 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed.
208S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
209S&F MCB SP 6 - 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Please Enable Macros to View BoQ information
210S&F MCB SP 6 - 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962382
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Certain Repair Of Chloronome Plants, Ro, Dg Sets, Cleaning Of Drinking Water, Ug Sumps, Over Head Tanks And Repair To Water Level Indicator, Primeing System, Lightening Protection, Earthing Pits And Misc Works In The Area Of Age(U) W/S No-Ii Under Ge (U) Water Supply Delhi Cantt-10
Basic Detail
Tender No GE/WS/Token No-42 OF 2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 11 Aug 2026
Submission Date 02 Sep 2026
Open Date 05 Sep 2026
Finance
Tender Value 44 Lakhs
Tender Fee 500
EMD 88000
Exemption Available
Document List
6182688b-2b42-442e-8bc4-a94fbec4c8da.html
BOQ_878234.xls
Tender.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

6182688b-2b42-442e-8bc4-a94fbec4c8da.html

xls

BOQ_878234.xls

pdf

Tender.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail