Tender For Repair To Ht Feeder, Vcbs, Underground Cable And Connected Works At Mil Stn Talbehat
Tender Value
25 Lakhs
Estimated cost
Bid Submission
05 Sep 2026
23 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lalitpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Ht Feeder, Vcbs, Underground Cable And Connected Works At Mil Stn Talbehat
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old damaged Cross arms, bracing supports, clamps and back plates fabricated from structural steel sections including nuts, bolts etc. |
| 2 | Taking down old unserviceable insulators of any type, any size. |
| 3 | Taking down old unserviceable stay assembly complete with accessories as shown in electrical plate no. 01, dia of stay rod is 20 mm. |
| 4 | Taking down the Old unused/rusted HT steel pole complete |
| 5 | M&L for Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate for foundations of poles, struts & stay assembly etc all as specified and directed. |
| 6 | M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in copping of poles etc including fair finishing the exposed surface even and smooth with out using extra cement and necessary form work all as specified and directed |
| 7 | M & L for cable end jointing kit incl taken out for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE cable armoured aluminium conductor of size 95 sq mm . |
| 8 | M & L for cable end jointing kit incl taken out for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE cable armoured, aluminium conductor of size 95 sq mm. |
| 9 | M&L for Cable jointing kit incl taken out for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95sqmm complete all as specified and directed including taking down old one. |
| 10 | Supply and Laying, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 volts earthed, FR, cross sectional area 95 sq mm 3 core all as specified and directed |
| 11 | Supply only 40 mm size stone aggregate grade 1 for spreading and leveled in Sub Station and around two pole/four pole structure all as specified and directed. |
| 12 | Installation cleaning, bushes and grass cutting including removing cutting materials complete all as specified and directed. |
| 13 | Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as spfd & directed. |
| 14 | Removing excavated material not exceeding 50mtr & deposited where directed at a level not exceeding 1.5mtrabove the ground level complete all as specified. |
| 15 | Returning , filling in spreading, leveling, watering & well Ramming in layers not exc 25cm thick complete all as specified and directed. |
| 16 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 2, flat size 300mm x 180mm x 40mm laid over cable complete all as specified and directed. |
| 17 | M&L for clean, dry river sand filled in trenches/ducts for cushioning of cables complete all as specified.Note :- The depth of cushion after punning (180mm) shall only be measured. |
| 18 | M & L for painting of tubular pole (Cross arms, clamps etc) with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height upto 9 m pole with 2 coats of synthetic enameled paint including preparation of old surfaces and making colour bands and rewriting the pole number complete all as directed. |
| 19 | M&L for earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, burried directly in ground,earth pit not less than 2.25 meter deep below ground level with top edge of earth plate not less than 1.5 meter below ground level, steel earth plate connected with 25x4 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel as shown in electrical plate No. 3 connected to earth test point all as described in MES schedule part II including excavation earth work concreate pit with 50 mm thick RCC cover in RCC 1:2:4 type B-I duly reinforced with MS bars 6 mm dia @ 150 C/C both ways and pit chamber in PCC 1:2:4 type B-I with 2 Nos suitable lifting handles of 12 mm MS bar and GI protection pipe of suitable size,and watering pipe 20 mm dia with water funnel test point and extra length up to 7.5 meter connected to Panel board all as specified. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. |
| 20 | S & F gang operated air break switchwith DO fuse assembly, three poles, outdoor type, nominal system voltage 11 KV, rated voltage 12 KV, rated normal current 200 Amps having 9 insulators, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 28 KV (rms) (ii) across the isolating distance 32 KV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 KV (Peak) (ii) across the isolating distance 85 KV (Peak), Rated short-time withstand current 25 KA for 3 seconds, rated peak withstand current 63 KA for climatic conditions at the site, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed. |
| 21 | On line dehydration/filtration of transformer oil with centrifuge machine of pole mounted or on platform mounted of any capacity as specified and directed by EIC.NOTE:- (i) Dielectric strength of Transformer oil should be not less than 60 KV at 4 mm Gap complete all specified and directed. (ii) Payment of new Transformer oil required for topping up at the time of dehydration and filtration shall be made separately. (iii) The test certificate before & after dehydration/filtration will be carried out by contractor. |
| 22 | M&L for spray painting outer surface of Transformer with two coat of synthetic enamel paint 1st quality after scraping removing dust and rusting, washing and cleaning of old paint outer surface of Transformer of capacity 100KVA to 250 KVA complete all as specified and directed. |
| 23 | M&L in for replacement of transformer breather complete with silica gel for capacity 100 KVA to 250 KVA step down transformer all as specified and directed. |
| 24 | M&L in replacement of top gasket appx 15 mm thick suitable for step down transformer (11/.433 KV) up to capacity of 250 KVA Transformer complete all as specified and directed. |
| 25 | M&L in replacement of off Tap changer coil suitable for 100 KVA to 250 KVA step down transformer complete all as specified and directed by EIC. |
| 26 | M&L in replacement of temp gauge for 100 KVA to 250 KVA step down transformer complete all as specified and directed by EIC. |
| 27 | M&L for filling of Transformer oil as topping up to level of Transformer level indicator's mark having dielectric strength not less than 60 KV at 4 mm gap with confirming to IS-335 by heating up and after filtration. |
| 28 | Supply and fixing framed work as in doors or gates of angle made out of FE 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing inclusive of one primer coat, one under coat and one finishing coat of paint. complete all as specified and directed. |
| 29 | M&L including fabrication of existing panel cover with hing, nut and bolt with two coat painting complete all as specified and directed. |
| 30 | Supply and fixing in replacement of MCCB 4 pole , 160 amp adjustable thermal and adjustable magnetic type of rating 36 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed |
| 31 | Supply and fixing in replacement of MCCB 4 pole , 200 amp adjustable thermal and adjustable magnetic type of rating 36 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed |
| 32 | Supply and fixing in replacement of MCCB 4 pole , 250 amp adjustable thermal and adjustable magnetic type of rating 36 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed |
| 33 | Supply and fixing in replacement of MCCB 4 pole , 400 amp adjustable thermal and adjustable magnetic type of rating 36 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed |
| 34 | M & L for repairing and servicing two/four pole structures comprising of following works :- (a) Dismantling the ACSR jumper connection from Air break Gang operated drop out fuse end lightening arrestors etc from the two/four poles structures, replacing the complete jumpers in to new with ACSR conductors including connecting with suitable thimbles connections/binding/PG clamps and providing monoplast compound over binding/thimble connectionsb) Removing the complete rusted bolts, nuts and washers and replacing with new bolts, nuts and washers(c) Disconnecting the AB switch knives cleaning and servicing by lubricating the moving parts terminals with petroleum jelly. (d) Cleaning the exposed surfaces of two pole structure complete and painting with two coats of synthetic enamel aluminium paint all as specified and directed. |
| 35 | M & L for painting of two pole structures of steel/rail/steel tubular pole in E/M installation complete including all cross arms, clamps etc with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height with 2 coats of synthetic enameled paint including preparation of old surfaces complete all as directed. |
| 36 | M & L for painting of three pole structures of steel/rail/steel tubular pole in E/M installation complete including all cross arms, clamps etc with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height with 2 coats of synthetic enameled paint including preparation of old surfaces complete all as directed. |
| 37 | M & L for painting of four pole structures of steel/rail/steel tubular pole in E/M installation complete including all cross arms, clamps etc with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height with 2 coats of synthetic enameled paint including preparation of old surfaces complete all as directed. |
| 38 | S&F lightening arrestor expulsion type complete with fittings, transmission class discharge capacity 10 KA suitable for 33000 Volts all as approved by AGE (I) . |
| 39 | S&F lightening arrestor expulsion type complete with fittings, transmission class discharge capacity 10 KA suitable for 11000 Volts all as approved by AGE (I) . |
| 40 | Supply and fixing in repair pin type porcelain vitreous white or brown or green insulators of size 150 mm height and 150 mm dia for 11 KV grade and on galvanised mild steel spindle, two GI washers and one No GI nut complete conforming to the latest IS all as specified. |
| 41 | Supply and fixing in repair post type porcelain vitreous white or brown or green insulators of size 150 mm height and 150 mm dia for 11 KV grade and on galvanised mild steel base nut bolts complete conforming to the latest IS all as specified. |
| 42 | Supply and fixing in repair disc type insulator porcelain, vitreous white, brown or green of size 145 mm high and 255 mm dia ball and socket type with clamps suitable for Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified. |
| 43 | Inspection, servicing, testing, checking and calibration of 11 KV VCB panel consisting of one incoming and four outgoing (total VCB 05 Nos) for servicing, cleaning, tightening of loose mechanical mechanism, greasing inspection of busbar, CTs/PTs, internal wiring of control panel, indicators, measuring of IR value, calibration of relays, replacement of unserviceable spare parts, testing of tripping system, to maintain desired insulation level of each panel and removing all type of dust and settled dirt by mechanical means including testing complete all as specified and as directed by AGE (I) including the followings: -(a) Cleaning of Vacuum Circuit Breaker with CRC-226.(b) To check the condition of SIC contacts.(c) Checking condition and alignment of jaw contact.(d) Checking and proper tightening of hardware.(e) Checking of proper closing/ open of all poles.(f) Checking of breaker tripping through push button.(g) Checking and adjusting gap between hylem sheet and side plate.(h) Checking motor operation in case of EDO.(i) Checking auxiliary contacts continuity proper change over.(j) Checking of presence if circlips.(k) Checking IR between phase to phase (VCB closed condition).(l) Checking IR between phase to earth (VCB closed condition).(m) Checking IR between phase to earth (VCB open condition).(n) Cleaning and providing lubricants on movable mechanical parts.(o) Testing of relays through secondary injections.(p) Tripping of VCB through Buchholz relay/ OTI/WTI if required.(q) Testing of CTs and PT.(s) Testing of contact resistance of VCBsNote: - (i) Servicing shall be carried out by authorised rep of VCB manufacturer. |
| 44 | S&F in ground PCC cable route indicator duly engraved with words \\"HT Cable\\" and arrow indicating direction of laying of cable, complete all as specified and directed.Note. PCC cable route indicator shall be provided at specified distance along the HT cable at all cable joint and turning etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender