Tender For Engineering Procurement And Construction (Epc) For Provision Of Balance Tech Infrastructure At Mamun Military Station.
Tender Overview
Project Description
Tender for Engineering Procurement And Construction (Epc) For Provision Of Balance Tech Infrastructure At Mamun Military Station.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Aug-2026 | Corrigendum | Date | 16-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Engineering Procurement and Construction of Technical Infrastructure works as listed in Sch 'A' Part-I, as detailed in scope of work, DBR, drawings & other documents of the tender, complete all as specified and directed. |
| 2 | Lumpsum price worked out by the contractor for EARTHWORK AND SITE CLEARANCE WORKS as listed in Schedule 'A' Part-II. |
| 3 | Lumpsum price worked out by the contractor for TAXI TRACK/DISPERSAL WORKS as listed in Schedule 'A' Part-III. |
| 4 | Lumpsum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-IV. |
| 5 | Lumpsum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-V. |
| 6 | Lumpsum price worked out by the contractor for DEMOLITION OF EXISTING SECURITY WALL WORKS as listed in Schedule 'A' Part-VI. |
| 7 | Sch 'A' Part-VIII (Misc Items) |
| 8 | SUMMER APPLIANCESPoint wiring for metal plug top AC point using 4.0 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable drawn in including non-metallic rigid PVC concealed conduit (ISI marked) not less than 20mm dia, including FRLS PVC insulated unsheathed multi-stranded copper conductor cable of size 4.0 Sqmm (green colour) earth wire connecting to earth dolly, complete all as specified and directed. |
| 9 | Sheet metal enclosures single pole and neutral 240 volt, 32 Amps with two pin and earth plug and socket plug top complete with single pole MCBs, complete all as specified and directed. |
| 10 | Hi wall split units indoor/outdoor complete with cordless remote control unit and with in built Heating and cooling arrangement and Digital Inverter twin rotary of capacity 1.5 TR, 5 Star Rated, complete all as specified and directed. |
| 11 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage 80 ltrs and nominal cooling capacity 40 ltrs including 02 nos of PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified and directed. |
| 12 | Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA, complete all as specified and directed. |
| 13 | Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA, complete all as specified and directed. |
| 14 | RUNWAY/TAXI LIGHT WORKDWC (Double Wall Corrugated) pipe of 75 mm bore as per IS-16205 laid for protection of cables in trenches, complete all as specified and directed. |
| 15 | Galvanised steel wire 4 mm dia, complete all as specified and directed. |
| 16 | Replacement of Gl tubing light grade 50 mm bore for passing through cables under the floor along the wall or along the pole, complete all as specified and directed |
| 17 | Supply, laying and testing of XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade, cross sectional area 35 sqmm 3.5 core, complete all as specified and directed. (Notes:- Excavation earth shall be measured and paid separately |
| 18 | Supply, laying and testing of 6 sqmm, single core, 5KV grade stranded copper conductor PVC insulated and sheathed runway cable laid in trenches / wall / pipe jointed incl plug receptacle connector for jointing of cable, complete all as specified and directed.Notes:-(i) Excavation and earthwork required will be measured and paid separately.(ii) All tests of cable should be done at company/ manufacturer premises before delivery at site in presence of MES Rep/Accepting officer and all test certificates to be submitted to office. |
| 19 | Poking of ground surface upto depth of 1 mtr for a distance of 30 mtr by Mechanical means, of dia 75 mm hole alongwith HDPE PVC pipe of 40 mm dia PN 20 (SDR 7.4) of length 30 mtr including all jointing, HDPE accessories like sockets, threading etc all as required site, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 20 | Poking of ground surface upto depth of 1 mtr for a distance of 30 mtr by Mechanical means, of dia 75 mm hole alongwith HDPE PVC pipe of 40 mm dia PN 20 (SDR 7.4) of length 30 mtr including all jointing, HDPE accessories like sockets, threading etc all as required site, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 29 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 29 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 36 daysTender Documents