Tender For Repair / Maintenance Of Perimeter Security Light, High Mast Light And Misc Work At Certain Location At Af Stn Bihta.
Tender Value
11 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
17 days left
EMD
22000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patna → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Perimeter Security Light, High Mast Light And Misc Work At Certain Location At Af Stn Bihta.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n. exc 1.5 m wide for foundations of PCC / Steel Pole , laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 2 | Excavation in trenches n exc 1.5 m wide for foundations of PCC / Steel Pole , laying cables/ pipes etc. exc 1.5 m but not exceeding 3.0 m deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified. |
| 4 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 5 | Cutting the existing road straight by manual, depth and width not less than 1 metre below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 using 20mm graded aggregate stone complete all as specified. |
| 6 | NOTES APPLICABLE TO SERIAL ITEM 1 TO 5: (a) Excavation work shall be carried out manually only.(b) LT/HT cable, water supply/ sewage/telephone lines, if any, get damaged during excavation & earthwork, demolition of PCC shall be repaired by the contractor immediately as per existing specifications to the entire satisfaction of Engineer-in-Charge. |
| 7 | Brick protection with Sub class 'B' bricks laid flat across the route of underground cable all as specified. |
| 8 | Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified.NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. |
| 9 | PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in foundation of electric poles, struts, PCC block including necessary form work and fair finish to exposed surfaces without using extra cement etc. complete all as specified and directed |
| 10 | PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in as in foundation of electric pole, stay assembly and strut PCC block including necessary form work and fair finish to exposed surfaces without using extra cement etc. complete all as specified and directed |
| 11 | PCC type B-1 (1:2:4), using 20 mm graded stone aggregates as in coping of poles etc. with slightly rounded or chamfered angles including necessary form work and fair finishing the exposed surface without using extra cement complete all as specified and directed |
| 12 | GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc complete including taking down existing tube all as specified of following size: - |
| 13 | 40 mm bore |
| 14 | 50 mm bore |
| 15 | Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including takind down existing cable complete all as specified of sectional area: - |
| 16 | 6 Sq.mm,2 core |
| 17 | 10 Sq.mm,2 core |
| 18 | 10 Sq.mm,4 core |
| 19 | 16 Sq.mm,4core |
| 20 | 25 Sq.mm,4 core |
| 21 | 70 Sq.mm,3.5 core |
| 22 | PVC insulated & sheathed industrial HV round multicore flexible cable with copper conductor twin core 1.5 Sq.mm including PVC conduit 20mm dia medium grade and necessary bends fittings and fixture as required for connection of light fittings completed all as specified and directed. |
| 23 | PVC insulated & sheathed industrial HV round multicore flexible cable with copper conductor twin core 2.5 Sq.mm including PVC conduit 20mm dia medium grade and necessary bends fittings and fixture as required for connection of light fittings completed all as specified and directed. |
| 24 | PVC insulated unsheathed / sheathed cable with standard aluminium conductor 1100 Volts grade flat twin core service cable of size 4 sqmm confirming to IS:694/1990 with latest amendement ISI including disconnecting / taking out existing unsv/damaged old service cable completed all as specified and directed. |
| 25 | PVC insulated unsheathed / sheathed cable with standard aluminium conductor 1100 Volts grade flat twin core service cable of size 6 sqmm confirming to IS:694/1990 with latest amendement ISI including disconnecting / taking out existing unsv/damaged old service cable completed all as specified and directed. |
| 26 | Cable joining kit (straight through heat shrinkable) for 1100 V (Earthed) grade cable complete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified of following size: - |
| 27 | 10-50 Sq. mm, 3.5 to 4 core |
| 28 | 70-95 Sq. mm, 3.5 core |
| 29 | Taking out and Relaying of LT cable of size 10 Sq mm to 70 Sqmm 2 core/3.5 core/4 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: (Earth work , sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevent Item) |
| 30 | LED street light fittings 60 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 31 | LED street light fittings 70/72 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 32 | LED street light fittings 90 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 33 | LED street light fittings 100 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 34 | LED street light fittings 120 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 35 | LED flood light fittings 100 watt , outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 36 | LED flood light fittings 120 watt , outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 37 | LED flood light fittings 200 watt , outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W IP 66 protection, IN REPLACEMENT, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, complete. |
| 38 | Post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X35/40 watt, fixed to Pole/Wall in any position IN REPLACEMENT, complete all as specified and directed |
| 39 | Automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP and and automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 three phase load of 12 KW with circuit wiring min 10 sq mm, 3 nos contactor each of 40 - 50 amps, incoming outgoing MCB (3 nos) rating 40 amps of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos) for fixing on pole / walll, IN REPLACEMENT, complete all as directed |
| 40 | Taking down old unsv Street light/flood light fittings in any position of any capacity for repair by replacement of unsv spares (SPD / Driver /MCB etc ) and re-fixing the same in existing location.Note :- Spares for repair of street light fitting will be measured and paid underrespective itmes |
| 41 | Supply only LED driver 60-72 watt suitable for existing LED lights |
| 42 | Supply only LED driver 90-120 watt suitable for existing LED lights |
| 43 | Supply only LED driver 150-250 watt suitable for existing LED lights |
| 44 | Taking down serviceable street light fittings of any watt and type from existing position on pole/ wall/ tower including bracket / clamp and refix the same at new location in pole complete all as specefied and directed. |
| 45 | Material and labour for taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheated weatherproof 3 X single core cable for electrical connection and refixing the fitting after repair to its original/New location or as directed by engg-in-charge.(connecting wire will be measured and paid separately only) |
| 46 | Taking down existing high mast system / tower of any description from any height for checking functioning including repair, servicing, lubrcation, overhauling etc. to raising and lowering system, double drum winch, tightening of trailing cable, up and down of lantern carriage and re-fixing of light fitting(s) and making connections inluding necessary repairs/replacement of defective parts within 24 hour of receipt of complaint to the contractor by the MES, complete.NOTE: Supply only parts will be measured & paid for separately under respective item |
| 47 | Supply only Reverse forward switch |
| 48 | Supply only pulley for geared motor |
| 49 | Supply only gear box oil |
| 50 | Supply only nuts, bolts, washer Please Enable Macros to View BoQ information |
| 51 | Supply only nuts, bolts, washer Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender