Tender For Repair/Maint/Servicing Of Voltage Stabilizers, Dg Sets Lightening Protection, Water Purifiers, Cooling Appliances And Other Connected Works At Pooh And Sumdo Area Under Ge 863 Ews.
Tender Overview
Project Description
Tender for Repair/Maint/Servicing Of Voltage Stabilizers, Dg Sets Lightening Protection, Water Purifiers, Cooling Appliances And Other Connected Works At Pooh And Sumdo Area Under Ge 863 Ews.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 31-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Repair / maintenance and servicing of water cooled / air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete all as specified and directed for the following capacities:-(a) 50 KVA - 03 Nos. & 160 KVA - 02 No at PoohNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch 'A'/BOQ. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted. |
| 2 | Repair / maintenance and servicing of water cooled / air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete all as specified and directed for the following capacities:-(b) 10 KVA - 01 No. & 30 KVA - 04 Nos. at SumdoNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch 'A'/BOQ. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted. |
| 3 | Repair / maintenance and servicing of water cooled / air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete all as specified and directed for the following capacities:-(c) 12 BHP - 01 No. Diesel engine pumpset at SumdoNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch 'A'/BOQ. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted. |
| 4 | Supply only element diesel filter with gasket of existing size and model DG set capacity mentioned in item No 1 (a) to (c) complete all as specified and directed. |
| 5 | Supply only element oil filter with gasket of existing size and model mentioned in item No 1 (a) to (c) complete all as specified and directed. |
| 6 | Supply only inner and outer air cleaner element of existing size and model mentioned in item No 1 (a) to (c) complete all as specified and directed. |
| 7 | Suppply only element bypass filter with gasket of existing size and model / make mentioned in item No 1 (a) to (c) complete all as specified and directed. |
| 8 | Supply only lubrication oil SAE-40 (20w-40 grade) complete all as specified and directed.Make : Servo/HP/BPCL/Castrol) |
| 9 | Dismantling / In site Cleaning and calibration of the fuel tank of various capacities, by using 'K' oil and remove sludge accumulated inside the tank, replacement of fuel tank strainer, cap and unserviceable fuel indicatior including refixing after repair / welding the leakage portions complete all as specified and directed by Engr-in-Charge |
| 10 | S & F connecting and testing battery lead (Heavy duty) PVC insulated with multi stranded copper conductor single core of size 25 sqmm one side fixed with clamp and other side fixed with brass battery terminal for 2 mtr length suitable colour coding for phase and earth complete all as specified and directed |
| 11 | S & F in replacement of AutoOff/Maintain-This 12V-24V Battery Charger Offers Two Charging Modes.The Auto Shut-Off Mode Stops charging the Battery Is fully Charged ,Preventing the OVER Chargeing.Desined For All Climates,the specily winter mode provides a more Completecharge Double Wound Transformer ,Analog For Indicating Charging Current With AC Mains Switch ON OFF Illuminated,DC out Put Circuit Breaker Copper based Solid For Heavy Duty DG Set/Vechile or Industrial Battery charger with connecting wires Length 2 Meters Each-1set With copper Quality Battery Clamps Complete all as Specfied and directed |
| 12 | S & F in replacement of battery maint free type 100Ah/150 Ah complete all as specified and directed Make: Exide/Amaron/TATA |
| 13 | Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & opening of servo operated oil cooled voltage stabilizer of cap 100 KVA , single/three phase, 50 Hz and draining out of transformer oil, replacement of UNSV/defective wiring parts as per existing sizes, dimmerstat, carbon brush, servo motor of existing capacity, control card, etc and complete servicing including filteration & refilling of transformer oil with top-up of new oil if required, reassembling, connecting and testing complete all as specified and directed by Engr-in-Charge |
| 14 | All as per item No. 11 here in before but capacity 250 KVA, three phaseNote for Item No. 11 &12 :- Replacment of spare parts/accessories shall be measured & paid seperately as 'Supply Only' on relevant items. |
| 15 | Supply only Dimmerstat as per existing size and make complete all as specified and directed |
| 16 | Supply only Servo control motor Cap 10 Kgs, 60 RPM & 240 volts for existing voltage stabilizer as per existing size and make complete all as specified and directed. |
| 17 | Supply only Push Buttons for adjustment of voltage complete all as specified and directed |
| 18 | Supply only Carbon brush as per existing size and make complete all as specified and directed. |
| 19 | Supply only voltmeter digital type, 0-500 volts, 96mm x 96mm square size including wiring, suitable for voltage stabilizers complete all as specified and directed. Make: AE/L&T/Seimens |
| 20 | Supply only indicator lamp pilot type (RYB) complete all as specified and directed. |
| 21 | Supply only selector switch suitable for voltmeter, 3 way, ON/OFF type complete all as specified and directed.Make : GEPC/PAAS/Concord/Vaishno/Legrand Lexic |
| 22 | Supply only PCB card as per sample complete all as specified and directed. |
| 23 | Supply only Transformer oil EHV conforming to IS-335 of 1983 having high dielectric strength not less than 50KV in drums/barrel complete all as specified and directed. |
| 24 | S&F in replacement of copper strip 20 x 3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed |
| 25 | S&F in replacement of aluminium strip 25 x 3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed |
| 26 | S&F in repair air termination single pointed Copper rod 12mm dia and 300 mm long incl fixing on roof with MS clamp and nut, bolt and washers etc complete all as directed |
| 27 | S&F in repair air termination single pointed aluminium rod 12mm dia and 300 mm long incl fixing on roofl with MS clamp and nut, bolt and washers etc complete all as directed |
| 28 | S&F in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed |
| 29 | M&L Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip 32 x 6 mm dia protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 meter from earth pit, common salt, charcoal dust and connected to test point by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavation in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete all as specified and directed |
| 30 | Servicing of Window / Split AC 1.5 / 2 TR capacities any make by opening the indoor/outdoor unit, cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, rectification of loose electric connections and replacement of unserviceable knobs of electrical items complete all as directed Note : Replacement of spare parts will be measured and paid separately under relevant items of Sch 'A' |
| 31 | Supply only starting capacitor 80-100 mfd |
| 32 | Supply only running Capacitor 36 mfd |
| 33 | Supply only starting relay |
| 34 | Supply only Over load protector |
| 35 | Supply only thermostat |
| 36 | Supply only Air Filter |
| 37 | Removing the existing defective / short circuited hermetically sealed compressor unit from the ACs and replace with the same company rewound sealed compressor unit of appropiate make / model for 1.5 TR AC. |
| 38 | Servicing, maintenance and repairs to Refrigerator / Deep Freezer of capacity 280 to 386 Ltrs of any make and model including periodical cleaning to condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed Note : Replacement of spare parts will be measured and paid separately under relevant items of Sch 'A' |
| 39 | Supply & fix in replacement of Voltage Stabilizer for AC/Deep Freezer automatic operation/single phase AC supply 230 Volt/50 HZ naturally air cooled indoor type designed for input variation between 130 V to 280 Volt with output Voltage stabilizer at 230 V of capoacity 2 to 5 KVA complete all as specified and directed. |
| 40 | Supply only Starting Relay |
| 41 | Removing the existing defective / short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewound sealed compressor unit of appropriate make / model for Refrigerator cap: 280 to 380 ltrs |
| 42 | Gas charging with refrigerant to ACs/water cooler/Deep freezer /Refrigerator including arresting of existing leakage by brazing work complete and all as specified and directed |
| 43 | S & F in replacement of solar street light fitting 12 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete all as specified and directed |
| 44 | M&L for servicing, cleaning of water purifier 8/10 LPH, any make & model complete all as specified and directed. Note: Replacement of following items shall be measured & paid separately as \\"Supply only\\" |
| 45 | Supply only Sediment filter |
| 46 | Supply only Carbon filter |
| 47 | Supply only UV filter |
| 48 | Supply only Membrane |
| 49 | Supply only Pre-filter candle |
| 50 | M&L for servicing, cleaning of Industrial type RO plant 50 to 100 LPH, any make & model complete all as specified and directed. Note: Replacement of following items shall be measured & paid separately as \\"Supply only\\" |
| 51 | Supply only pressure regulator |
| 52 | Supply only Sediment Pre-filter |
| 53 | Supply only Carbon filter |
| 54 | Supply only RO membrane |
| 55 | Supply only Post Caron inline filter |
| 56 | Supply only Pressure pump booster |
| 57 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender