Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56962330

Tender For Repair/Maint/Servicing Of Voltage Stabilizers, Dg Sets Lightening Protection, Water Purifiers, Cooling Appliances And Other Connected Works At Pooh And Sumdo Area Under Ge 863 Ews.

Issued by Statutory Bodies & Commissions/Committees · Kinnaur, Himachal Pradesh
Tender Value
10 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
2 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kinnaur → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint/Servicing Of Voltage Stabilizers, Dg Sets Lightening Protection, Water Purifiers, Cooling Appliances And Other Connected Works At Pooh And Sumdo Area Under Ge 863 Ews.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-Aug-2026

BOQ

Name of Work:- REPAIR/MAINT/SERVICING OF VOLTAGE STABILIZERS, DG SETS LIGHTENING PROTECTION, WATER PURIFIERS, COOLING APPLIANCES AND OTHER CONNECTED WORKS AT POOH AND SUMDO AREA UNDER GE 863 EWS.
Sl. No. Item Description
1Repair / maintenance and servicing of water cooled / air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete all as specified and directed for the following capacities:-(a) 50 KVA - 03 Nos. & 160 KVA - 02 No at PoohNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch 'A'/BOQ. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
2Repair / maintenance and servicing of water cooled / air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete all as specified and directed for the following capacities:-(b) 10 KVA - 01 No. & 30 KVA - 04 Nos. at SumdoNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch 'A'/BOQ. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
3Repair / maintenance and servicing of water cooled / air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete all as specified and directed for the following capacities:-(c) 12 BHP - 01 No. Diesel engine pumpset at SumdoNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch 'A'/BOQ. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
4Supply only element diesel filter with gasket of existing size and model DG set capacity mentioned in item No 1 (a) to (c) complete all as specified and directed.
5Supply only element oil filter with gasket of existing size and model mentioned in item No 1 (a) to (c) complete all as specified and directed.
6Supply only inner and outer air cleaner element of existing size and model mentioned in item No 1 (a) to (c) complete all as specified and directed.
7Suppply only element bypass filter with gasket of existing size and model / make mentioned in item No 1 (a) to (c) complete all as specified and directed.
8Supply only lubrication oil SAE-40 (20w-40 grade) complete all as specified and directed.Make : Servo/HP/BPCL/Castrol)
9Dismantling / In site Cleaning and calibration of the fuel tank of various capacities, by using 'K' oil and remove sludge accumulated inside the tank, replacement of fuel tank strainer, cap and unserviceable fuel indicatior including refixing after repair / welding the leakage portions complete all as specified and directed by Engr-in-Charge
10S & F connecting and testing battery lead (Heavy duty) PVC insulated with multi stranded copper conductor single core of size 25 sqmm one side fixed with clamp and other side fixed with brass battery terminal for 2 mtr length suitable colour coding for phase and earth complete all as specified and directed
11S & F in replacement of AutoOff/Maintain-This 12V-24V Battery Charger Offers Two Charging Modes.The Auto Shut-Off Mode Stops charging the Battery Is fully Charged ,Preventing the OVER Chargeing.Desined For All Climates,the specily winter mode provides a more Completecharge Double Wound Transformer ,Analog For Indicating Charging Current With AC Mains Switch ON OFF Illuminated,DC out Put Circuit Breaker Copper based Solid For Heavy Duty DG Set/Vechile or Industrial Battery charger with connecting wires Length 2 Meters Each-1set With copper Quality Battery Clamps Complete all as Specfied and directed
12S & F in replacement of battery maint free type 100Ah/150 Ah complete all as specified and directed Make: Exide/Amaron/TATA
13Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & opening of servo operated oil cooled voltage stabilizer of cap 100 KVA , single/three phase, 50 Hz and draining out of transformer oil, replacement of UNSV/defective wiring parts as per existing sizes, dimmerstat, carbon brush, servo motor of existing capacity, control card, etc and complete servicing including filteration & refilling of transformer oil with top-up of new oil if required, reassembling, connecting and testing complete all as specified and directed by Engr-in-Charge
14All as per item No. 11 here in before but capacity 250 KVA, three phaseNote for Item No. 11 &12 :- Replacment of spare parts/accessories shall be measured & paid seperately as 'Supply Only' on relevant items.
15Supply only Dimmerstat as per existing size and make complete all as specified and directed
16Supply only Servo control motor Cap 10 Kgs, 60 RPM & 240 volts for existing voltage stabilizer as per existing size and make complete all as specified and directed.
17Supply only Push Buttons for adjustment of voltage complete all as specified and directed
18Supply only Carbon brush as per existing size and make complete all as specified and directed.
19Supply only voltmeter digital type, 0-500 volts, 96mm x 96mm square size including wiring, suitable for voltage stabilizers complete all as specified and directed. Make: AE/L&T/Seimens
20Supply only indicator lamp pilot type (RYB) complete all as specified and directed.
21Supply only selector switch suitable for voltmeter, 3 way, ON/OFF type complete all as specified and directed.Make : GEPC/PAAS/Concord/Vaishno/Legrand Lexic
22Supply only PCB card as per sample complete all as specified and directed.
23Supply only Transformer oil EHV conforming to IS-335 of 1983 having high dielectric strength not less than 50KV in drums/barrel complete all as specified and directed.
24S&F in replacement of copper strip 20 x 3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed
25S&F in replacement of aluminium strip 25 x 3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed
26S&F in repair air termination single pointed Copper rod 12mm dia and 300 mm long incl fixing on roof with MS clamp and nut, bolt and washers etc complete all as directed
27S&F in repair air termination single pointed aluminium rod 12mm dia and 300 mm long incl fixing on roofl with MS clamp and nut, bolt and washers etc complete all as directed
28S&F in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed
29M&L Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip 32 x 6 mm dia protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 meter from earth pit, common salt, charcoal dust and connected to test point by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavation in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete all as specified and directed
30Servicing of Window / Split AC 1.5 / 2 TR capacities any make by opening the indoor/outdoor unit, cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, rectification of loose electric connections and replacement of unserviceable knobs of electrical items complete all as directed Note : Replacement of spare parts will be measured and paid separately under relevant items of Sch 'A'
31Supply only starting capacitor 80-100 mfd
32Supply only running Capacitor 36 mfd
33Supply only starting relay
34Supply only Over load protector
35Supply only thermostat
36Supply only Air Filter
37Removing the existing defective / short circuited hermetically sealed compressor unit from the ACs and replace with the same company rewound sealed compressor unit of appropiate make / model for 1.5 TR AC.
38Servicing, maintenance and repairs to Refrigerator / Deep Freezer of capacity 280 to 386 Ltrs of any make and model including periodical cleaning to condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed Note : Replacement of spare parts will be measured and paid separately under relevant items of Sch 'A'
39Supply & fix in replacement of Voltage Stabilizer for AC/Deep Freezer automatic operation/single phase AC supply 230 Volt/50 HZ naturally air cooled indoor type designed for input variation between 130 V to 280 Volt with output Voltage stabilizer at 230 V of capoacity 2 to 5 KVA complete all as specified and directed.
40Supply only Starting Relay
41Removing the existing defective / short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewound sealed compressor unit of appropriate make / model for Refrigerator cap: 280 to 380 ltrs
42Gas charging with refrigerant to ACs/water cooler/Deep freezer /Refrigerator including arresting of existing leakage by brazing work complete and all as specified and directed
43S & F in replacement of solar street light fitting 12 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete all as specified and directed
44M&L for servicing, cleaning of water purifier 8/10 LPH, any make & model complete all as specified and directed. Note: Replacement of following items shall be measured & paid separately as \\"Supply only\\"
45Supply only Sediment filter
46Supply only Carbon filter
47Supply only UV filter
48Supply only Membrane
49Supply only Pre-filter candle
50M&L for servicing, cleaning of Industrial type RO plant 50 to 100 LPH, any make & model complete all as specified and directed. Note: Replacement of following items shall be measured & paid separately as \\"Supply only\\"
51Supply only pressure regulator
52Supply only Sediment Pre-filter
53Supply only Carbon filter
54Supply only RO membrane
55Supply only Post Caron inline filter
56Supply only Pressure pump booster
57Schedule of Credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962330
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint/Servicing Of Voltage Stabilizers, Dg Sets Lightening Protection, Water Purifiers, Cooling Appliances And Other Connected Works At Pooh And Sumdo Area Under Ge 863 Ews.
Basic Detail
Tender No GE/863/EWS-T-65 OF 2026-27
Bidding Type Tender
Location
City Kinnaur
State Himachal Pradesh
Key Dates
Publish Date 24 Aug 2026
Submission Date 31 Aug 2026
Open Date 07 Sep 2026
Finance
Tender Value 10 Lakhs
Tender Fee 500
EMD 20000
Exemption Available
Document List
5d8e94ac-7ac4-4bd6-8ef4-643f16f1e6d2.html
BOQ_878307.xls
TD65.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

5d8e94ac-7ac4-4bd6-8ef4-643f16f1e6d2.html

xls

BOQ_878307.xls

pdf

TD65.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders