Tender For Special Repair /Replacement To Ht Cable From Samra Substation To Substation 8A Under Ge (N) Binnaguri
Tender Value
39.50 Lakhs
Estimated cost
Bid Submission
05 Sep 2026
20 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair /Replacement To Ht Cable From Samra Substation To Substation 8A Under Ge (N) Binnaguri
BOQ
| Sl. No. | Item Description |
| 1 | M&L for taking out old unserviceable cable with jointing kit of any size from trenches , GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed.(Note : (i) The Excavation and earth work shall be mesured and paid separately under relevant item of Sch). |
| 2 | Supply, laying, jointing & testing in trenches or passing through pipe, 11000 volts grade (Earthed), XLPE insulated PVC bedded, galvanized steel strip or wire armoured HT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area of size 3 core 95 sq mm with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). |
| 3 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed. |
| 5 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 6 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. |
| 7 | Refixing only serviceable PCC cable cover obtained from item No 01 here in before complete all as specified and as directed. |
| 8 | Supplying and Laying Un-inforced precast concrete cable cover , class HVP type 1 with peak size 300mm x 180mm x 40mm all as specified and directed. |
| 9 | M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'. |
| 10 | M&L 100 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. |
| 11 | Material & labour for cable End jointing kit for 11 KV (earthed) grade cable, for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for XLPE insulated armoured aluminium conductor cable of size 3 Core 95 sqmm complete all as specified and directed. |
| 12 | M&L for precast cable route indicator of size 100x30x10 Cms by using 20 mm graded aggregate type B1 1;2;4 for cable indicator and engraving as \\"HT CABLE\\" slightly round from one side incl Red painting with two coat of synthetci enamel paint of a coat of primer complete all as specified & directed |
| 13 | Dismantling of old U/S 11 KV junction box including foundation after disconnecting of all elecrical connection complete all as specified and as directed. |
| 14 | Supply and installation (above ground) including testing HT joint box (CPRI approved)3 way outdoor type of size 1700x1200x1500mm (overall) made out 3.15mm thick CRCA sheet with supprt of angle iron frame of size 40x40x6mm with KIOSK BOX and comprising of 06 Nos HT procelain bushing and copper round bus bar 12mm dia rigidly mounted on bakelite sheet 12mm thick to support insulatiors of suitable size and shape including providing necessary electric connection and applied two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces (internally & externally) including PCC foundation base of suitable size with PCC 1:3:6 type C1 using 20mm graded aggregate complete including necessary excavation and earth work for foundation and necessary electric connection complete and including dismantling of unserviceable joint box complete all as specified and as directed.NOTE : (i)Cost of digging of HT UG cable loop are included in unit rate.(ii) Valid CPRI approved certificate needs to be produced before execution of work. |
| 15 | Material and labour for PCC 1:2:4 type C2 using 40mm graded stone aggregate for foundation of poles, stay etc complete all as specified and directed. |
| 16 | M&L in replacement for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip complete all as specified and directed. Note: (i) Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate.(ii) Contractor shall produce valid Electrical Licence before execution of work.(iii) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender