Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56962295

Tender For Repair Maintenance And Replacement Of Lt Panels , Servo Stabilizers, Solar Panels, Capacitors Bank, Lt Switch Gears And Allied Em Works At Af Station Suratgarh

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
45 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
9 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance And Replacement Of Lt Panels , Servo Stabilizers, Solar Panels, Capacitors Bank, Lt Switch Gears And Allied Em Works At Af Station Suratgarh

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Aug-2026 Corrigendum_01 Other 02-Sep-2026

BOQ

Name of Work:- REPAIR MAINT AND REPLACEMENT OF LT PANELS , SERVO STABILIZERS, SOLAR PANELS, CAPACITORS BANK, LT SWITCH GEARS AND ALLIED EM WORKS AT AF STATION SURATGARH
Sl. No. Item Description
1BOQ (REPAIR MAINT AND REPLACEMENT OF LT PANELS , SERVO STABILIZERS, SOLAR PANELS, CAPACITORS BANK, LT SWITCH GEARS AND ALLIED EM WORKS AT AF STATION SURATGARH)
2Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and as directed by Engr-In-Charge.
3All as per item Srl No 1 here-in-before but in PCC/floor/road
4All as per item Srl No 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre
5Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified.
6Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
7S&F as in replacement GI Tubing light grade 100 mm nominal bore for cable potection in road/floor all as specified and directed
8S&F as in replacement GI Pipe light grade 80mm nominal bore for cable protection in floor/road crossing/along pole complete all as specified and as directed.
9S&F for laying in replacement HDPE Double Wall Corrugated pipe of size 63mm outer dia confirming to IS:16205 Part-24 and IS 14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. including fixed to wall/roof /pole/trench as required with suitable clamps for cable protection complete all as specified and directed.
10Supplying and laying of nominal size 90 mm dia (OD-90 mm) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 and IS: 14930 Part II complete with fitting and cutting, jointing etc. direct in ground, complete as required.
11Taking out from trenches/floors/road/wall/pipe/pole LT cable of any size/description and removing & reuse from site incl making good the disturbed surfaces to match with existing surface all as directed.
12Relaying/Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, upto 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 25 sqmm 4 core cable obtained from item no-10 here-in-before shall be resued with required aluminium cable lugs.
13All as per item No. 11 here-in-before but 35 sqmm 3.5 core to 120 sqmm, 3.5 core complete all as specified and directed
14All as per item No. 11 here-in-before but 150 sqmm 3.5 core to 400 sqmm, 3.5 core complete all as specified and directed
15Supply & laying of LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 240 Sqmm 3.5 core as per IS 7098 (Part-I) laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. (Note: (i) Cable joint and excavation / earth work shall be measured and paid separately.)
16All as per item No. 16 here-in-before but 185 sqmm 3.5 core complete all as specified
17All as per item No. 16 above but of cross sectional area 150 Sqmm, 3.5 core.
18All as per item No. 16 above but of cross sectional area 120 Sqmm, 3.5 core.
19All as per item No. 16 above but of cross sectional area 95 Sqmm, 3.5 core.
20All as peritem No. 16 here-in-before but 70 sqmm 3.5 core complete all as specified
21All as per item No. 16 above but of cross sectional area 50 Sqmm, 3.5 core.
22Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 70-120 sqmm, 4 core complete all as specified by Engr-in-Charge ,
23Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 150 sqmm, 4 core complete all as specified by Engr-in-Charge .
24Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 240-300 sqmm, 4 core complete all as specified by Engr-in-Charge .
25Supply and fix Heat shrink straight through joint LT 1100 volts grade 70-120 sqmm, 4 core complete all as specified by Engr-in-Charge.
26Supply and fix Heat shrink straight through joint LT 1100 volts grade 150-185 sqmm, 4 core complete all as specified by Engr-in-Charge.
27Supply and fix Heat shrink straight through joint LT 1100 volts grade 240-300 sqmm, 4 core complete all as specified by Engr-in-Charge.Note for Srl item to :- Excavation & earth work shall be measured and paid separately.
28S&F as in replacement Cable route indicator showing \\"LT Cable\\" and route of cable with arrow made of CI in suitable eliptical/round shape and fixed on angle iron 40x40x6mm, 800mm long painted in Blue Colour with two coats of synthetic enamel paint cover a coat of red oxide primer duly embedded in PCC block (0.40x0.40x0.40)mtr below in ground and 0.15mtr above ground lable complete all as directed and specified.
29M&L for earthing complete with GI earth plate 600x600x6mm thick electrode and 32x6 mm GI strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to GI strip earth lead by means of bolts, nuts, check , nuts and washers of galvanised iron or steel all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.(Note: GI strip beyond 7.5Mtr length from earth electrode shall be measured and paid separately).
30All as per item No 28 above but with 4 mm dia GI wire as earthing lead and GI protection pipe 20mm dia medium grade.
31M&L for earthing complete with copper earth plate 600x600x3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.(Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item)
32S&F GI earthing strip 32x6mm fixed to wall/pole/buried in ground /drawn in pipe complete as directed by Engr-In-Charge.
33PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation, filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
34M&L for replacement of earth pit chamber of size 300 x300 mm (internal dimensions) and 450x450mm(External) with PCC 1:3:6 type C-1 , RCC 1:2:4 type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick with 12 mm dia MS hook of suitable size and shape for lifting and MS angle iron frame 50 x 50 x 4 mm including GI funnel with wiremesh complete all as specified.
35Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) in and around electrical sub stations, two/four pole structures and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge.
36Supply and fixing of synthetic insulating mat suitable for 11 KV installation of size 1.00 m x 2.00 m and 25mm thick (ISI marked) complete all as specified and directed.
37Supply and fixing Aluminium thimble/lugs suitable for 35 sqmm to 95 sqmm XLPE cable all as specified and directed.
38Supply and fixing Aluminium thimble/lugs suitable for 120 sqmm to 185 sqmm XLPE cable all as specified and directed.
39Supply and fix in replacement of MCCB 630 Amp rating,4-pole 415V, breaking capacity 50 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
40Supply and fix in replacement of MCCB 400Amp rating,4-pole 415V, breaking capacity 36 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
41Supply and fix in replacement of MCCB 320 Amp rating,4-pole 415V, breaking capacity 36 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
42Supply and fix in replacement of MCCB 250Amp rating,4-pole 415V, breaking capacity 36KA, Adjustable thermal & fixed magnetic setting type Ics 100% of Icuall as specified and directed.
43Supply and fix in replacement of MCCB 200Amp rating,4-pole 415V, breaking capacity 36KA, Adjustable thermal & fixed magnetic setting type Ics 100% of Icuall as specified and directed.
44Supply and fix in replacement of MCCB 160Amp rating,4-pole 415V, breaking capacity 36 KA, Adjustable thermal & fixed magnetic setting type Ics 75% of Icu all as specified and directed.
45Supply and fix in replacement of MCCB 125 Amp rating,4-pole 415V, breaking capacity 10 KA, Adjustable thermal & fixed magnetic setting type all as specified and directed.
46Supply and fix in replacement of MCCB 100 Amp rating,4-pole 415V, breaking capacity 10 KA, Adjustable thermal & fixed magnetic setting type all as specified and directed.
47Supply and fix in replacement of MCCB 320 Amp to 400 Amp rating,3-pole 415V, breaking capacity 36 KA, Adjustable thermal & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
48Supply and fix in replacement of MCCB 250Amp rating,3-pole 415V, breaking capacity 36KA. Adjustable thermal & fixed magnetic type setting Ics 100% of Icuall as specified and directed.
49Supply and fix in replacement of MCCB 200 Amp rating,3-pole 415V, breaking capacity 36KA. Adjustable & fixed magnetic type setting Ics 100% of Icuall as specified and directed.
50Supply and fix in replacement of MCCB 160 Amp rating,3-pole 415V, breaking capacity 36 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
51Supply and fix in replacement of MCCB 125 Amp rating,3-pole 415V, breaking capacity 10 KA, Adjustable magnetic & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
52Supply and fix in replacement of MCCB 40 to 100 amp Amp rating,3-pole 415V, breaking capacity 10 KA, Adjustable magnetic & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
53Labour for disconnecting LT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT cable laid in trenches or any location by locating fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge.Note: joint kit will be measured seperately in appropriate item in this schedule
54M&L for repair to street panel board indoor / outdoor type of any capacity having Incomming & out going MCCB , MCBs, timer switch and power contactor by carrying out the following works:-(i) Cleaning incomer switches, bus bar & out going switches etc thoroughly. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing.(iii) Making the locking arrangement functional including welding if required(iv) making proper connections for out going / incoming cable by providing suitable thimble as required.
55Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 80 mm dia and sealing the end of pipe complete all as specified and directed.
56Servicing of Air Circuit Breaker (ACB) rating 630 Amp to 1250 Amp installed in LT /HT Panel including isolation, dismantling, internal cleaning, checking of main and arcing contacts, tightening of all power and control connections, lubrication of moving parts, checking of spring charging mechanism, testing of closing/tripping operation, checking/calibration of protection relay settings, insulation resistance testing, re-fixing,commissioning and complete functional testing as directed by Engineer-in-Charge.Note: minor repair and calibration rate including in item.
57M & L for preperation of old painted surfaces of LT panel /AMF panel and applying two coat of blue/Gray enamel paint and writing with white enamel paint Danger symbol of size as directed complete all as specified and as directed.
58Material and labour for fixing of display Board of 60cmx30cm for earth pit made out of 2 mm thick MS sheet welded on angle iron legs 0.75 mtr long (02Nos) of size 40x40x6mm duly embedded in PCC block 1:2:4, type B-1, using gradedcrushed stone aggregate, of size 23x23x30cm fixed in ground including necessary earthwork. Display Board shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in- Charge. The following is to be written on the board:- a) Earth Pit No. b) Checked on c) Next due date.
59Supply and fixing in replacement voltmeter for LT panel/servo stablizer Square dial of size 96x96mm digital type complete all as specified and as directed.
60Supply and fixing in replacement Ammeter for LT panel /servo stablizer Square dial of size 100 mm digital type complete all as specified and as directed.
61Supply and fixing in replacement indicator lamp assembly in red,yellow & blue colour for LT panels complete all as specified and as directed.
62Supply and fixing automatic power factor controller relay 8 Steps as per complete all as specified and as directed.
63Supply and fixing automatic power factor controller relay (144x144 ) 12 Steps as per complete all as specified and as directed.
64Supply and fixing in replacement MCB TP rating 16-40 Amps, 3 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and as directed.
65Supply and fixing in replacement MCB SP rating 6-32 Amps, single pole, 240 volts complete all as specif ied and as directed.
66Material & labour in replacement of Automatic power factor contactor (built in auxilary contactor) of size as per suitable existing type as MNX 9/MO C3 type , 12 Amps, 440Volts capacitor cylinder suitable capacity complete all as specified and as directed.
67All as per Item No. 65.00 above but size MNX 12/MO C 5 25 Amps, 440Volts capacitor cylinder -ditto-
68All as per Item No.65.00 above but size MNX -18/MO C 10 , 32 Amps, 440Volts capacitor cylinder ditto-
69All as per Item No. 65.00 above but size MNX -32/MO C 20 40, 40 Amps, 440Volts capacitor cylinder s -ditto-
70Supply and fixing capacitor dry type non PCB cylindrical type heavy duty 3 phase, 440 volts supply system, rating 25 KVAR .
71Supply and fixing capacitor dry type non PCB cylindrical type heavy duty 3 phase, 440 volts supply system, rating 20 KVAR .
72Supply and fixing capacitor dry type non PCB cylindrical type heavy duty 3 phase, 440 volts supply system, rating 15 KVAR .
73Supply and fixing capacitor dry type non PCB cylindrical type heavy duty 3 phase, 440 volts supply system, rating 10 KVAR .
74Supply and fixing capacitor dry type non PCB cylindrical type heavy duty 3 phase, 440 volts supply system, rating 5 KVAR .
75Supply and fix as in replacement Rotary Handle for MCCB complete all as specified and as directed
76Supply and fix as in replacement CT 400/5A -03 Nos complete all as specified and as directed
77Supply and fix Auto Manual selector switch complete all as specified and as directed
78Supply and fix 240 VAC 2 NO+ 2 NC (aux cont block ) complete all as specified and as directed
79Supply and fix in replacement of ACB 630 Amp rating,4-pole 415V, breaking capacity 50 KA, Thermal magnetic realese setting (Manual fixed type) all as specified and directed.
80Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel outdoor type of suitable size, made out of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of MCCB & instumentations compartments and frame etc. to accommodate the incoming and outgoing MCCBs/ COs / Motor Starter duly powder coated (The inner/outdoor shell. will have powder coated siemens grey) and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts including aking down of old unsv LT panel complete all as specified and directed. Panel shall comprise of the following:-
81(a) Aluminium bus bar mounted on insulators duly painted colour code 600 Amps - 3 Nos for phase and 400 Amps - 01 No for neutral. (b) Incoming MCCB 4 pole, 400 Amps, rupturing capacity 36 KA,415 Volts AC, adjustable thermal and megnatic setting-01 No. (c) On load Changeover Switch 400 A ,4 pole (d) Out going MCCB's TP 200 Amps repturing capacity 36 KA - 01 No's (f) Out going MCCB's TP 100 Amps repturing capacity 16 KA - 03 No's (h) Space for MCB TPN /DP (g) Multifunction Meter Digital type showing V,A,F,Pf Kw,KWH in built Selector switch with CT coiles for three phase. Cat No WDM303FDWA1 of L&T Make:- L&T.(h) Indicator lamp neon type (RYB) with holder,one set for each incoming and out going - 01 Sets(j) Complete internal wiring with suitable sizes copper conductor PVC insulated all as per manufacturor design (k) Danger Notice plate 440V with conventional skull and bones in red signal colour.
82Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel outdoor type of suitable size, made ot of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of MCCB & instumentations compartments and frame etc. to accommodate the incoming and outgoing MCCBs/ COs / Motor Starter duly powder coated (The inner/outdoor shell. will have powder coated siemens grey) and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts including aking down of old unsv LT panel complete all as specified and directed. Panel shall comprise of the following:-
83(a) Aluminium bus bar mounted on insulators duly painted colour code 800 Amps - 3 Nos for phase and 600 Amps - 01 No for neutral. (b) Incoming ACB 4 pole, 630 Amps, rupturing capacity 50 KA,415 Volts AC, adjustable thermal and megnatic setting-01 No.(c) Out going MCCB's TP 400 Amps repturing capacity 36 KA - 01 No's (d) Out going MCCB's TP 320 Amps repturing capacity 36 KA - 01 No'sd) Out going MCCB's TP 200 Amps repturing capacity 36 KA - 01 No'sd) Out going MCCB's TP 100 Amps repturing capacity 16 KA - 01 No's(e) Multifunction Meter Digital type showing V,A,F,Pf Kw,KWH in built Selector switch with CT coiles for three phase. Cat No WDM303FDWA1 of L&T Make:- L&T.(hf) Indicator lamp neon type (RYB) with holder,one set for each incoming and out going - 01 Sets(j) Complete internal wiring with suitable sizes copper conductor PVC insulated all as per manufacturor design (k) Danger Notice plate 440V with conventional skull and bones in red signal colour.
84Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel outdoor type of suitable size, made ot of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of MCCB & instumentations compartments and frame etc. to accommodate the incoming and outgoing MCCBs/ COs / Motor Starter duly powder coated (The inner/outdoor shell. will have powder coated siemens grey) and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts including aking down of old unsv LT panel complete all as specified and directed.
85Panel shall comprise of the following:- (a) Aluminium bus bar mounted on insulators duly painted colour code 400 Amps - 3 Nos for phase and 200 Amps - 01 No for neutral. (b) Incoming MCCB 4 pole, 250 Amps, rupturing capacity 36 KA,415 Volts AC, adjustable thermal and megnatic setting-01 No.(d) Out going MCCB's TP 125 Amps repturing capacity 36 KA - 01 No's (f) Out going MCCB's TP 100 Amps repturing capacity 16 KA - 02 No's(f) Out going MCB TP 63 Amps repturing capacity 10 KA - 01 No's(f) Out going MCbs DP 63 Amps repturing capacity 10 KA - 01 No's(g) Multifunction Meter Digital type showing V,A,F,Pf Kw,KWH in built Selector switch with CT coiles for three phase. Cat No WDM303FDWA1 of L&T Make:- L&T.(h) Indicator lamp neon type (RYB) with holder,one set for each incoming and out going - 01 Sets(j) Complete internal wiring with suitable sizes copper conductor PVC insulated all as per manufacturor design (k) Danger Notice plate 440V with conventional skull and bones in red signal colour.
86Supply and installation, testing, commissioning Outdoor type feeder piller Box factory made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made CPRI Approved & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel grey paint including taking out existing panel complete all as specifed and directed and consisting of the following equipments:-
87(i) MCCB, 4 pole , 35/36 KA , 250 Amps -01 Nos ( Incomming)(ii) MCCB, 4 pole , 35/36 KA , 200 Amps -01 Nos (Out going) (iii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv)(viii) Solid aluminium bus bar 400 Amp for 3 phase and neutral (8 way ) for connecion of outgoing cable (ix) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge Note :- (i) Earth work, 1:2:4 PCC work for foundation and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable (iii) The contractor shall get the drawings approved by the accepting officer before placing the orders.
88Supply and installation, testing, commissioning Outdoor type feeder piller Box factory made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made CPRI Approved & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel grey paint including taking out existing panel complete all as specifed and directed and consisting of the following equipments:-
89(i) MCCB, 4 pole , 35/36 KA , 160 Amps -01 Nos ( Incomming)(ii) MCCB, 4 pole , 16 KA , 125 Amps -01 Nos (Out going) (iii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv)(viii) Solid aluminium bus bar 200 Amp for 3 phase and 150 amp for neutral ( 8 way O/P circuit terminal in busbar ) (ix) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge Note :- (i) Earth work, 1:2:4 PCC work for foundation and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable Please Enable Macros to View BoQ information
90(i) MCCB, 4 pole , 35/36 KA , 160 Amps -01 Nos ( Incomming)(ii) MCCB, 4 pole , 16 KA , 125 Amps -01 Nos (Out going) (iii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv)(viii) Solid aluminium bus bar 200 Amp for 3 phase and 150 amp for neutral ( 8 way O/P circuit terminal in busbar ) (ix) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge Note :- (i) Earth work, 1:2:4 PCC work for foundation and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962295
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Maintenance And Replacement Of Lt Panels , Servo Stabilizers, Solar Panels, Capacitors Bank, Lt Switch Gears And Allied Em Works At Af Station Suratgarh
Basic Detail
Tender No 8361/E8
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 22 Aug 2026
Submission Date 02 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
bf8f0710-ba81-4e4a-9500-70a58775f5e3.html
BOQ_878317.xls
Tenderdocuments8361.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

bf8f0710-ba81-4e4a-9500-70a58775f5e3.html

xls

BOQ_878317.xls

pdf

Tenderdocuments8361.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders