Tender For Repair/Maintenance Of Summer Appliances, Hot Water Appliances, Dg Sets, Amf Panels And Other Misc E/M Items Installed At Different Location At Af Stn Dadri Under Aor Of Ge (Af) Faridabad
Tender Value
38 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
2 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gautam Buddha Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Summer Appliances, Hot Water Appliances, Dg Sets, Amf Panels And Other Misc E/M Items Installed At Different Location At Af Stn Dadri Under Aor Of Ge (Af) Faridabad
BOQ
| Sl. No. | Item Description |
| 1 | Attending of day to day Solar Water Heating System complaints taking down, opening up, reassembling, refixing and testing of Solar Water Heating System including replacement of unserviceable parts wherever required at the discretion of the Engr-in- Charge shall be carried out by the contractor for efficient functioning of Solar Water heating System. The cost of material will be measured and paid seperately for replalacement of parts complete all as specified and directed.Note: (i) Schedule of repair to Solar Water heating System is catered for attending day to day complaints of different items within the prescribed time schedule as decided on complaint slip, failure to attend the complaint within the prescribed time shall attract a penalty of Rs 250 per day per complaint.Note: All repair to Solar water heating system shall be carried out from an authorized person of the manufacturer of the system and proof there of shall be produced to the GE before undertaking repairs. Contractor is advised to visit the site to ascertain the model and manufacturer of system before quoting his rates. |
| 2 | S&F in replacement to hose pipe for solar panel to hot water tank as per dia and thickness suitable for solar heating system of cap available in LPD by clamping/tightening properly for leak proof joint complete all as specified and directed |
| 3 | M&L for repairing of the leakage of solar hot water tank of any capacity in LPD by taking down removing insulation carefully complete and taking to workshop for necessary repair by soldering /welding including replacementhing density (48kg/m3) and K value 0.03W/mk to witn stand temp. upto 250 degree celcius and insulation materials injected of thickness 100mm and refixing of its original position for satisfactory functioning of the unit complete all as specified and directed. |
| 4 | S&F in replacment to old Unsv Broken solar water heater pannel ( Flate Plate Collector) with new one including necessary welding work and brazing work having 4 mm thick (min.) low iron tempered solar glass with a highly selective chromium oxide absorber plate beneath of the glass duly hosed in a corrosion resistant alumminium frame welded to the bottom of the absorber plate with parallel copper tubes confirming to IS 12933(Part I ) replacment of insulating material all as per exiting density. thickness and K value of capacity 100 LPD for solar water heating system, operating pressure 10 bar incl. civil works and making good the distrubed surface complete all as specified and directed. |
| 5 | S&F in repalacment of self priming monoblock pump set of cap. 0.5 HP single phase 220 Volts. +/_ 6% speed 2780 RPM complete all as specified and as directed |
| 6 | S&F in repalacment of broken/rusted steel hot water SS(20 SWG)tank (inner and outer tanks)of capacity suitable for 200 LPD solar water heater including high density (48 kg/M3 ) and K value 0.03 W/mK to with stand temp. upto 250 degree celcius and insulation material injected PUF insulation of thickness 100 mm complete all as specified and directed. |
| 7 | S&F in replacement rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) with capacity 1000 litres for make up water of solar water heater complete all as specified and directed . |
| 8 | Supply & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 15mm bore with connected accessories complete all as specified and directed. |
| 9 | Supply & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 20mm bore with connected accessories complete all as specified and directed. |
| 10 | Supply & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 25mm bore with connected accessories complete all as specified and directed. |
| 11 | Supply & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 32mm bore with connected accessories complete all as specified and directed. |
| 12 | S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 32mm bore pipe with connected accessories complete all as specified and directed. |
| 13 | S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25mm bore pipe with connected accessories complete all as specified and directed. |
| 14 | S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 20mm bore pipe with connected accessories complete all as specified and directed. |
| 15 | S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 15mm bore pipe with connected accessories complete all as specified and directed. |
| 16 | S&F in replacement Gun Metal angle valve with screwed both ends for iron pipe and fixed for 15mm bore pipe with connected accessories complete all as specified and directed. |
| 17 | S&F in replacement NRV 32mm dia made out of brass complete all as specified and directed. |
| 18 | S&F in replacement MS dead flange for plate collector of solar water heater panels as per existing size with gasket along with connected accessories complete all as specified and as directed |
| 19 | S&F in replacement gasket for flate plate collector of solar water heater as per existing size along with connected accessories complete all as specified and as directed |
| 20 | Taking down electric water heater/ geysers of capacity 25ltrs from its mounting place for repair and deposit to MES complaint cell and re-fixing the same after repair and testing complete all as specified and directed. |
| 21 | All as per item No 20 above but geyser of capacity 35 ltrs.NOTE : The spare items required for repair against item No. 1 & 2 will be measured and paid seperately. |
| 22 | S&F in replacement of heating element of 1.5 KW rating( for geyser model availbale at site) double tube type with cup type of circular/triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and directed. |
| 23 | S&F in replacement of heating element of 2 KW rating (for geyser models available at site) double tube type with cup type of circular /triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and directed. |
| 24 | S&F in replacement of heating element of 3 KW rating (for instant geyser model as per site )double tube type with cup type of circular /triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and directed. |
| 25 | S&F in replacement of complete set of round shape element holding assembly attached with heating element and thermostate made out of brass of capacity 2 KW rating 230V, 50 Hz, including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and directed. |
| 26 | S&F in replacement of the heat proof rubber PVC gasket suitable for the different make of 25 litres capacity geysers as per site requirement complete all as specified and directed. |
| 27 | S&F in replacement of heavy duty element holding assembly with provision for safety valve in its inlet, pocket for thermostat/ thermal cut system and drain plug suitable for 25 litres capacity geysers, complete all as specified and directed. |
| 28 | S&F in replacement of thermostate for the geysers 25 Ltrs. capacity as per site requirement complete all as specified and directed. |
| 29 | All as per item No 28 above but suitable for 35 ltrs capacity geysers. |
| 30 | S&F in replacement of safety valve/high pressure valve 15mm, as per site requirement complete all as specified and directed. |
| 31 | S&F in replacement of heavy duty PVC connecting pipe with brass adapters 450 mm long suitable for 15 mm dia pipe and fixing in position complete all as specified and directed. |
| 32 | S&F in replacement of 1100 Volts grade cable flexible, 3 core PVC insulated, PVC sheathed with stranded copper conductor of size 2.5 Sqmm, complete all as specified and directed. |
| 33 | S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed. |
| 34 | S&F in replacement of suitable fastener for geyser complete all as specified and directed. |
| 35 | S&F in replacement of indicating lamp red or green as per geyser suitability complete all as specified and directed. |
| 36 | S&F in replaccement of poreclain socket outlet 3 pin, 1 phase + 01 neutral suitable for metal clad socket complete all as specified and directed. |
| 37 | S&F in repalcement of metalic plug top 3 pin, 2 phase + 01 neutal suitable for metal clad socket complete all as specified and directed. |
| 38 | Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 2.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with GI saddles GI screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size on existing terminal boxes with new brass screws for mounting of one power point 6 pin 15 Amp switches and socket including earth wire 1.5 sqmm copper conductor cable connected to earth dolly for one socket outlet 20 Amp controlled by one switch o independent board complete all as specified and directed. |
| 39 | S&F for switch piano flush type single pole one way 15 Amps complete all as specified and directed. |
| 40 | S&F for socket outlet 2 in 1, 6 pin 5/15 Amps, flush type complete all as specified and directed. |
| 41 | S&F in replacement of switch socket combination multistranded 5 in 1, 5 and 15 Amps, flush type complete all as specified and directed. |
| 42 | S&F electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and directed. |
| 43 | M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1000 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including S&F following acessories:- INCOMING Changeover-250 Amp 4 pole front opertated 415V-01 (a) MCCB 200 Amps, 4 pole,36 KA - 01 Nos. (b) Digital type volt meter - set 01(c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01(d) LED type indicator lamp set of red , yellow and blue - set 01OUT GOING(a) MCCB 160 Amps, 4 pole, 25 KA DPX3 160 cat No 420096 - 01 Nos.(b) MCCB 63 Amps, 4 pole,25 KA DPX3 250 cat No 420249 - 03 Nos. |
| 44 | M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1000 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including S&F following acessories:- INCOMING(a) MCCB 200 Amps, 4 pole,36 KA - 01 Nos.(b) Digital type volt meter - set 01(c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01(d) LED type indicator lamp set of red , yellow and blue - set 01OUT GOING(a) MCCB 100 Amps, 4 pole, 25 KA DPX3 160 cat No 420096 - 02 Nos.(b) MCCB 63 Amps, 4 pole,25 KA DPX3 250 cat No 420249 - 01 Nos. |
| 45 | M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1000 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including S&F following acessories:- INCOMING (a) MCCB 250 Amps, 4 pole,36 KA - 01 Nos. (b) Digital type volt meter - set 01(c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01(d) LED type indicator lamp set of red , yellow and blue - set 01OUT GOING(a) MCCB 160 Amps, 4 pole, 25 KA DPX3 160 cat No 420096 - 01 Nos.(b) MCCB 63 Amps, 4 pole,25 KA DPX3 250 cat No 420249 - 03 Nos. |
| 46 | M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1000 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including S&F following acessories:- INCOMING (a) MCCB 400 Amps, 4 pole,36 KA - 01 Nos. (b) Digital type volt meter - set 01(c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01(d) LED type indicator lamp set of red , yellow and blue - set 01OUT GOING(a) MCCB 100 Amps, 4 pole, 25 KA DPX3 160 cat No 420096 - 01 Nos.(b) MCCB 63 Amps, 4 pole,25 KA DPX3 250 cat No 420249 - 03 Nos. |
| 47 | M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 25x4 mm as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner complete all as specified and directed.Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI) |
| 48 | S&F in repair LED street light fittings 90 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver ,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete on existing street light poles complete all as specified and directed. |
| 49 | Maintenance and servicing of DG sets once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as filters, gaskets, V belts, Engine oil, rubber hoses, worm drive clamps, nut bolts and cleaning of alternator with vaccum cleaner and CTC attending faults of AMF panels and greasing of bearings of engine and alternator, checking of batteries, adding distilled water, checking of oil and coolant levels complete all as specified and directed. Note : - (i) Spares required for above maintenance will be measured and paid separately under relevant item.(ii) All work pertains to DG set shall be executed only through authorised service provider of OEM of respective DG set. The contractor has to submit MOU with the authorised service provider. The authorised service provider shall give his complete investigation report of respective DG set seperately on his first visit to each DG set. |
| 50 | All as per item No 49 above but DG Set 160 KVA, Location : SS1 |
| 51 | All as per item No 49 above but DG Set 160 KVA, Location : SS2 |
| 52 | All as per item No 49 above but DG Set 75 KVA, Location : AFNET |
| 53 | All as per item No 49 above but DG Set 75 KVA, Location : AFNET |
| 54 | All as per item No 49 above but DG Set 62.5 KVA, Location : SS1 |
| 55 | All as per item No 49 above but DG Set 30 KVA, Location : SS3 |
| 56 | All as per item No 49 above but DG Set 30 KVA, Location : Pump house |
| 57 | All as per item No 49 above but DG Set 20 KVA, Location : SS1 |
| 58 | Supply only diesel filter element with O ring, suitable for following capacities of DG sets complete all as specified and directed :- |
| 59 | All as per item No 58 above but DG Set 30/20 KVA |
| 60 | All as per item No 58 above but DG Set 75/62.5 KVA |
| 61 | All as per item No 58 above but DG Set 160 KVA |
| 62 | Supply only oil filter element with O ring, suitable for following capacities of DG sets complete all as specified and directed :- |
| 63 | All as per item No 62 above but DG Set 30 KVA |
| 64 | All as per item No 62 above but DG Set 75/62.5 KVA |
| 65 | All as per item No 62 above but DG Set 160 KVA |
| 66 | All as per item No 62 above but DG Set 20 KVA |
| 67 | Supply only by pass filter element with O ring suitable for following capacities of DG sets complete all as specified and directed:- |
| 68 | All as per item No 67 above but DG Set 20/30 KVA |
| 69 | All as per item No 67 above but DG Set 75/62.5 KVA |
| 70 | All as per item No 67 above but DG Set 160 KVA |
| 71 | Supply only air filter element suitable for following capacities of DG sets complete all as specified and directed :- |
| 72 | All as per item No 71 above but DG Set 30/20 KVA |
| 73 | All as per item No 71 above but DG Set 75/62.5 KVA |
| 74 | All as per item No 71 above but DG Set 160 KVA |
| 75 | Supply only fan belt suitable for following capacities of DG sets complete all as specified and directed :- |
| 76 | All as per item No 75 above but DG Set 30/20 KVA |
| 77 | All as per item No 75 above but DG Set 75/62.5 KVA |
| 78 | All as per item No 75 above but DG Set 160 KVA |
| 79 | Supply only battery charging alternator belt suitable for following capacities of DG sets complete all as specified and directed :- |
| 80 | All as per item No 79 above but DG Set 30/20 KVA |
| 81 | All as per item No 79 above but DG Set 75/62.5 KVA |
| 82 | All as per item No 79 above but DG Set 160 KVA |
| 83 | Supply only rubber hose pipe set for water circuit complete with clamps, suitable for following capacities of DG sets complete all as specified and directed :- |
| 84 | All as per item No 83 above but DG Set 30/20 KVA |
| 85 | All as per item No 83 above but DG Set 75/62.5 KVA |
| 86 | All as per item No 83 above but DG Set 160 KVA |
| 87 | S&F in replacement PVC insulated multisranded , copper conductor 70 sqmm multistranded of 1.25 mtr long battery leads each duly fixed with brass clamps, copper lugs suitable for DG sets installed at different locations complete all as specified and directed. |
| 88 | Supply only engine oil, multi grade 20w / 40 complete all as specified and directed |
| 89 | Supply only coolant complete all as specified and directed |
| 90 | Supply and applying Petroleum jelly.(1 kg plastic sealed container) complete all as specified and directed |
| 91 | Supply and fill in batteries distilled water for topping up complete all as specified and directed |
| 92 | M & L for Dismantling of radiator , taking it to work shop for overhauling & cleaning descaling with acid removal of leakage, welding brazing & refixing it duly repaired etc complete all as specified and directed |
| 93 | All as per item No 92 above but DG Set 30/20 KVA |
| 94 | All as per item No 92 above but DG Set 75/62.5 KVA |
| 95 | All as per item No 92 above but DG Set 160 KVA |
| 96 | Calibration of FIP and injectors from the authorised dealer including petty repairs to make the FIP functional for the following capacities of DG sets including necessary spares required for smooth functioning of FIP complete all as specified and directed. Note : A Certificate to the effect that the calibration and repairs has been carried out by the authorised dealer shall be submitted by the contractor. |
| 97 | All as per item No 96 above but DG Set 75/62.5 KVA |
| 98 | All as per item No 96 above but DG Set 160 KVA |
| 99 | M&L for tappet setting of following capacities of DG sets complete all as specified and directed. |
| 100 | All as per item No 99 above but DG Set 30 KVA |
| 101 | All as per item No 99 above but DG Set 75/62.5 KVA |
| 102 | All as per item No 99 above but DG Set 160 KVA |
| 103 | S&F solenoid valve suitable for following capacity DG sets complete all as specified and directed. |
| 104 | All as per item No 103 above but DG Set 20/30/75/62.5 KVA |
| 105 | All as per item No 103 above but DG Set 160 KVA |
| 106 | M&L for repair / overhauling of self starter incl. replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as directed for the following capacity complete all as specified and directed:- |
| 107 | All as per item No 106 above but DG Set 24 Volts |
| 108 | All as per item No 106 above but DG Set 12 Volts |
| 109 | S&F in replacement self starter for suitable of upto 30 KVA DG set capcity including all necessary electrical connections complete all as specified and directed |
| 110 | S&F in replacement self starter for suitable of 50 KVA to 100 KVA DG set capcity including all necessary electrical connections complete all as specified and directed |
| 111 | S&F in replacement self starter for suitable of 160 KVA DG set DG set capcity including all necessary electrical connections complete all as specified and directed |
| 112 | S&F in repair automatic voltage regulator up to 125 KVA complete all as specified and directed. |
| 113 | S&F in repair automatic voltage regulator above 125 KVA upto 160 KVA complete all as specified and directed. |
| 114 | S&F in repair control wiring of the DG set up to 100 KVA complete incl provision of additional auto cables heavy duty suitable for Gen set application complete all as specified and directed. |
| 115 | S&F in repair control wiring of the DG set above 100 KVA up to 160 KVA complete incl provision of additional auto cables heavy duty suitable for Gen set application complete all as specified and directed |
| 116 | S&F in replacement 24 Volts SMPS battery Charger complete all as specified and directed |
| 117 | S&F in replacement 12 Volts SMPS battery Charger complete all as specified and directed |
| 118 | S&F in replacement lead acid maintenance free battery 180 AH, 12 V, complete all as specified and directed |
| 119 | S&F in replacement lead acid maintenance free battery 150 AH ,12 Volt complete all as specified and directed |
| 120 | S&F in replacement lead acid maintenance free battery 100 AH ,13 Volt complete all as specified and directed |
| 121 | S&F in replacement of digital multi function meter to read voltage, current and power factor complete all as specified and directed |
| 122 | S&F in replacement of 3 pole power contactor MNX 265 complete all as specified and directed |
| 123 | S&F in replacement of 3 pole power contactor MNX 400 complete all as specified and directed Please Enable Macros to View BoQ information |
| 124 | S&F in replacement of 3 pole power contactor MNX 400 complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender