Tender For Repair/ Maintenance Of Synchronizing Panel, Amf Panel And Apfc Panel And Allied Work At Af Stn Carnicobar 8833/E8
Tender Value
44 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
8 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Synchronizing Panel, Amf Panel And Apfc Panel And Allied Work At Af Stn Carnicobar 8833/E8
BOQ
| Sl. No. | Item Description |
| 1 | S&F in replacement of aluminium bus bar PVC insulated in RED,yellow,Blue & Black colours of rating 2000 Amps |
| 2 | S&F in replacement of insulator of appropriate size for panel mounting with existing one complete all as directed by Engr-in-Charge |
| 3 | M&L taking down shutdown the LT panel and disconnecting the power cable for necessary repair and servcing of ACB 800 Amps to 1600 Amps including necessary spare parts and testing complete including all as specified and directed by Engr-in-Charge. |
| 4 | Supply & fixing in replacement of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1250 Amps as per existing make and model, including dismantling & taking out old unserviceable ACB from panels and proper fitting in existing panel complete all as specified and directed by Engr-in-Charge.Make: ABB Model SACE EMAX (SACE PR 121/P) |
| 5 | Supply & fixing in replacement of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps as per existing make and model, including dismantling & taking out old unserviceable ACB from panels and proper fitting in existing panel complete all as specified and directed by Engr-in-ChargeMake: 02 No L&T Model No CN-CS800S1 & 01No- ABB Model SACE EMAX (SACE PR 121/P) |
| 6 | Supply & fixing in replacement of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1000 Amps as per existing make and model, including dismantling & taking out old unserviceable ACB from panels and proper fitting in existing panel complete all as specified and directed by Engr-in-Charge.Make: ABB Model SACE EMAX (SACE PR 121/P) |
| 7 | Supply & fixing in replacement of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 2000 Amps as per existing make and model, including dismantling & taking out old unserviceable ACB from panels and proper fitting in existing panel complete all as specified and directed by Engr-in-ChargeMake: L&T Model No CN-CS1600S1 |
| 8 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 400 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 9 | Supply and fix in replacement of 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA, fixed properly at directed location and connecting/testing complete all as specified and directed.Make: Havells/ L&T / Legrand |
| 10 | Supply and fix in replacement of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA, fixed properly at directed location and connecting/testing complete all as specified and directed.Make: Havells/ L&T / Legrand |
| 11 | Supply and fix in replacement of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA, fixed properly at directed location and connecting/testing complete all as specified and directed.Make: Havells/ L&T / Legrand |
| 12 | Supply and fix in replacement of 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 36KA, fixed properly at directed location and connecting/testing complete all as specified and directed.Make: Havells/ L&T / Legrand |
| 13 | Supply and fix in replacement of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA, fixed properly at directed location and connecting/testing complete all as specified and directed.Make: Havells/ L&T / Legrand |
| 14 | Supply and fix in replacement of 4 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA, fixed properly at directed location and connecting/testing complete all as specified and directed.Make: Havells/ L&T / Legrand |
| 15 | S&F in repairs voltmeter digital type for voltage range of (0-500V) including all accessories and wiring complete all as specified and as directed. Make:- AE/L&T. |
| 16 | S&F in repairs ammeter digital type for current range of (0-1000Amps) as per matching to existing including all accessories and wiring complete all as specified and as directed. Make:- AE/L&T. |
| 17 | S&F in repairs Multifunctional meter digital type (MFM 4410 LED meter CI1) as per matching to existing including all accessories and wiring complete all as specified and as directed. Make:- AE/L&T. |
| 18 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I(2009)Note: Unit rate quoted shall be deemed to be included the following (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 19 | M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 25x4mm galvanised iron strip all as directed by Engr-in-charge. |
| 20 | Supply and fixing of Aluminium thimble of size 25-35 sqmm for terminal end of cable complete all as specified and directed. |
| 21 | Supply and fixing of Aluminium thimble of size 150-240 sqmm for terminal end of cable complete all as specified and directed. |
| 22 | Supply and fixing of Aluminium thimble of size 300-400 sqmm for terminal end of cable complete all as specified and directed. |
| 23 | Supply and fixing in replacement VFD E 415 Volt 3 phase for 2 HP motor panel for motorised door all as specified and directed as per exiting make and model . Make : Delta |
| 24 | Supply & fixing in replacement of FRLS cable PVC insulated & PVC round sheathed bright annealed copper conductor flexible cable for 04 Core 10 Sqmm voltage grade upto 1100 V as per IS 694/1990 complete all as specified & directed by Engr-in-Charge. |
| 25 | Supply & fixing in replacement of FRLS cable PVC insulated & PVC round sheathed bright annealed copper conductor flexible cable for 04 Core 4 Sqmm voltage grade upto 1100 V as per IS 694/1990 complete all as specified & directed by Engr-in-Charge. |
| 26 | Supply & fixing in replacement of FRLS cable PVC insulated & PVC round sheathed bright annealed copper conductor flexible cable for 04 Core 2.5 Sqmm voltage grade upto 1100 V as per IS 694/1990 complete all as specified & directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 27 | Supply & fixing in replacement of FRLS cable PVC insulated & PVC round sheathed bright annealed copper conductor flexible cable for 04 Core 2.5 Sqmm voltage grade upto 1100 V as per IS 694/1990 complete all as specified & directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender