Tender For Repair/Replacement Of Feedar Pillars, Junction Boxes, Capacitor Banks, Lt Ug Cable And Other Allied Wks Under Ge (A) Ahmedabad

Issued by Statutory Bodies & Commissions/Committees · Ahmedabad, Gujarat
Tender Value
13 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
16 days left
EMD
26000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmedabad → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Feedar Pillars, Junction Boxes, Capacitor Banks, Lt Ug Cable And Other Allied Wks Under Ge (A) Ahmedabad

BOQ

Name of Work:- REPAIR/REPLACEMENT OF FEEDAR PILLARS, JUNCTION BOXES, CAPACITOR BANKS, LT UG CABLE AND OTHER ALLIED WKS UNDER GE (A) AHMEDABAD
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (ARMY) AHMEDABAD NAME OF WORK : REPAIR/REPLACEMENT OF FEEDAR PILLARS, JUNCTION BOXES, CAPACITOR BANKS, LT UG CABLE AND OTHER ALLIED WKS UNDER GE (A) AHMEDABAD CONTRACT AGREEMENT: GE (A)/ABD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words)
2Supply, errect, test and commissioning LT panel out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 3.15 mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 800 Amps capacity insulated, fixed with epoxy based Digital ammeter 0-800 amps, with CTs, Digital voltmeter 0-800 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation minimum 60cm from normal ground level comprising the following:- size - approx (1.5 x 1x 0.5Mtr)(i) Incoming (Main) :- One numbers MCCB 400 amp, 4 pole, Ics 50 KA, 415 volts, 50 Hz Make Legrand Outgoing:- (i) Two Numbers MCCB 250 amp, 4 pole, Ics 16 KA, 415 volts, 50 Hz Make Legrand.(ii) Two Numbers MCCB 200 amp, 4 pole, Ics 16 KA, 415 volts, 50 Hz Make Legrand.(iii) Two Numbers MCCB 100 amp, 4 pole, Ics 16 KA, 415 volts, 50 Hz Make Legrand.(iv) One Number of 24 Hours Nature timer switch
3M&L for feeder pillar bus bar panel outdoor type, double door, both side openable, locking arrangement, kiosk type, powder coated, 3.00mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 400 Amp duly colour coded mounted on porcelain insulator, with provn of 06 Nos outgoings including MCCB 250 Amps, 4 pole, 36 kA,= 01 No, LED indicator (RYB), 08 Nos, holes in bottom for inlet and outlet cable with suitable size of cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 mm X 50 mm X 6 mm, 1.05 metre high (450mm below ground level and 600mm above ground) along with necessary cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed by Engineer-in-Charge.Note : (a) Feeder pillar box shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only (b) Electric connection between MCCB and Busbar shall be with aluminium strip links duly colour coded.(c) MCCB shall be of Make-Havells/Legrand/ABB/C&S/L&T
4Material and labour for servicing, repairing and welding to out door LT Panel / LT Feeder Piller box by (i) Cleaning with blower, (ii) Cleaning with CTC/Petrol (iii) Replacement of damaged copper/aluminium lugs (iv) Replacement of deteriorated copper wiring with existing sizes of cable (v) Cleaning and tightening of MCCB terminals (vi) Replacement and fixing of sheared rubber beadings (vii) Rectifying of loose connections of incoming and outgoing cables (viii) Painting two coat of smoke gray colour over one coat of primer and black paint on base channel after rubing with emery paper and making smooth finishes by using spray machine inclusive of writing SM / MES No / name of feeders etc. (not exceeding of height 5 cm each) (ix) Providing of door locking arrangement with of sliding bolts on panel door (x) Proper welding of Panel door/roof as required (xi) Connecting / cleaning of earth wire /earth strip (x) Two coat of white distemper on foundation.
5Labour for laying of existing cable , of any size aluminimum armoured type from existing overhead complete all as directed.
6Taking down old rusted galvanized iron pipe including supply & Fix galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.
7All as per Item no-4 above but of size 80 mm complete all as specified and directed.
8All as per Item no-4 above but of size 40 mm complete all as specified and directed.
9All as per Item no-4 above but of size 32 mm complete all as specified and directed.
10Supply, laying and testing of LT UG cable of size 3.5 core 185 sq.mm , XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
11Supply, laying and testing of LT UG cable of size 3.5 core 150 sq.mm , XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
12Supply, laying and testing of LT UG cable of size 3.5 core 120 sq.mm , XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
13Supply, laying and testing of LT UG cable of size 3.5 core 95 sq.mm , XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
14Supply, laying and testing of LT UG cable of size 3.5 core 70 sq.mm , XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
15Excavation in trenches in any type of hard/dense soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
16Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
17Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
18Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 77mm, inner dia 63mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
19All as per Item no-17 above but of size outer dia 120 mm and inner dia 103 mm complete all as specified and directed.
20Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- MCCB Four pole 250 Amp, 36/35kA, 415 V, Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts as per existing make & model
21Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- but rating FP 160 Amp, 36 kA ,as per existing make & model
22Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:-but rating FP 125 Amp, 25 kA, as per existing make & model
23Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:-but rating FP 63 Amp, 16 kA, as per existing make & model
24Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- but rating TP 100 Amp , 16kA. as per existing make & model
25Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- MCCB Four pole 630 Amp, 50kA Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts Make : Legrand/Havells/L&T/Simens/Indoasian
26Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- MCCB Four pole 400 Amp, 36/35kA, Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts Make : Legrand/Havells/L&T/Simens/Indoasian
27Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- Digital Voltmeter of rating 0-500 V , size 96mm square type
28Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- Digital Ammeter of rating upto 0-600 Amp, size 96mm square type
29Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- Selector switch rotary type as per existing size and Make.
30Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- LED Indicator assy with colour red/ yellow/ blue. (Set of 3)
31Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- Current transformer (CT) Copper wound ratio 100/5 Amp (Set of 3 Nos).
32Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- Current transformer (CT) Copper wound ratio 200/5 Amp (Set of 3 Nos).
33Supply and fixing Onload Change over switch of capacity 400 A, 4 Pole, 415 Vols, 50 Hz, with Panel Mounted rotating handle, including dismantling old unserviceable change over switch by disconnection all incoming and outgoing electrical connection from existing indoor LT Panel complete all as specified and directed.
34All as per item No- 32 but of capacity 250 A, 4 Pole, 415 Vols,
35All as per item No- 32 but of capacity 125 A, 4 Pole, 415 Vols,
36All as per item No- 32 but of capacity 100 A, 4 Pole, 415 Vols,
37M&L surface dressing n.exc 150mm deep in soft/loose soil complete all as specified and dorected.
38M&L Hard core of gauge n.exe.63mm with broken stone boulders, deposited spread and levelled in layers not exe 15 cm thick watered and rolled rammed to a true surfaces
39M&L for 75mm thick cement concrete type D2 1:4:8 (40mm graded stone aggregate) incl necessary form work as in sub base of path complete all as specified and all as directed by engr-in-charge
40M & L for sand filling under floors or in foundations including watering and consolidation.
41M&L Machine pressed precast conctete interlocking paverblock any shape and size confirming to IS 15658-2006of 80 mm thickness, M-40 Grade with grey cement and pigment, set, jointed all as specified and as directed by Engr-in-charge.
42Removal of surplus material to a distance exc 250 m but n.exc 500 mtr and deposited where directred at a level not exc 1.50 m above starting point
43Excavation in post hole for similar holes each n exc 0.50Cum getting out returning filling in and ramming earth around in layers nexc 25 cm watering and removed surplus soil to a distance nexc 50m and making good surface in soft/loose soil.
44M & L for cement concrete 1:3:6 type C2 using (40mm graded stone aggregate) as in foundation filling mass concrete complete all as specified
45Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit(resistivity is less than 0.12 Ohm meter). The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 5000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including medium grade rigid PVC conduit upto 7 mtr incl cutting and chases on wall / floor and making good using PCC work complete all as specified and directed.
46Calibration of Digital protective relays of VCB comprising of 3 Phase, over current plus earth fault relay with high and low set operational with 24 volt to 110 volts AC / DC, Dc dual rated CT model MC 61A as per Cat Part no-MC 61 Anx of L&T including complete wiring with suitable size wire as per existing and fixing arrangement complete as secified and directed. Make :- siemens/CG/schneider/ L&T/ C&S/ABB
47Supply and fixing of cable jointing kit 11 KV (earthed) grade cable for indoor Terminal with long sleeves (Heat shinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
48Supply and fixing of cable jointing kit 11 KV (earthed) grade cable for Out door Termination (heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120Sqmm to 185 Sqmm complete all as specified and directed.
49All as per Item No - 47 above but of size 3 core 95 Sqmm complete all as specified and directed.
50Material and labour for replacement of existing old unserviceable alluminium tube terminals (Thimbles) of size 150 sqmm to 300 sqmm complete all as specified and as directed.
51All as per Item no-49 above but of size 95 sqmm to 120 sqmm complete all as specified and directed.
52All as per Item no-49 above but of size 50 sqmm to 70 sqmm complete all as specified and directed.
53All as per Item no-49 above but of size 35 sqmm to 50 sqmm complete all as specified and directed.
54All as per Item no-49 above but of size 25 sqmm complete all as specified and directed.
55All as per Item no-49 above but of size 6 sqmm to 16 sqmm complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962285
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Feedar Pillars, Junction Boxes, Capacitor Banks, Lt Ug Cable And Other Allied Wks Under Ge (A) Ahmedabad
Basic Detail
Tender No 8374/E8
Bidding Type Tender
Location
City Ahmedabad
State Gujarat
Key Dates
Publish Date 11 Aug 2026
Submission Date 31 Aug 2026
Open Date 03 Sep 2026
Finance
Tender Value 13 Lakhs
Tender Fee 500
EMD 26000
Exemption Available
Document List
BOQ_878247.xls
c4d17520-3c35-44bb-b8c8-5b0ab44e6aed.html
TENDER8367.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_878247.xls

html

c4d17520-3c35-44bb-b8c8-5b0ab44e6aed.html

pdf

TENDER8367.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders