Tender For Special Repairs To Amf Panel For Standby Dg Sets Installed At Transmitter, Officers Mess, Logistics Section, Afnet, Old Atc, Hrdf And Wsa Dg Sets At Af Stn Carnicobar.
Tender Value
46 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
8 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Amf Panel For Standby Dg Sets Installed At Transmitter, Officers Mess, Logistics Section, Afnet, Old Atc, Hrdf And Wsa Dg Sets At Af Stn Carnicobar.
BOQ
| Sl. No. | Item Description |
| 1 | Taking out old unserviceable panel board from existing position and making good of disturbed portion of floor and wall including disconnecting all cables and joints complete all as specified and as directed. |
| 2 | Supply installing testing and commissioning factory made and tested, CPRI approved AMF panel for 160 KVA DG set, outdoor type, double door operated, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mm CRCA mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated Al. bus bar 1500 Amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCB with suitable capacity of Al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments and and comprising of the following including necessary excavation, PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size all as standard practice of manufacturer specifications with the following accessories:-Location: WSA area |
| 3 | INCOMER-1 & 2 (MAIN & DG) FOR 160 KVA DG SET:(a) BUSBARS: 400A TPN 415Volts 3Phase 4 Wire Color Coaded Aluminium busbars- 1 Lot(b). MCCB 250A FP EDO 36KA Microprocessor Based and power contactor 250Amps 4pole 36KA - 2 Nos. (c) AMF Relay (econ) 1 Nos. (i). Digital Ammeter 1 Nos. (ii). Digital Voltmeter 1 Nos. (iii). CT 100/5A CL1 10VA 1 Nos. (iv). Phase Indication Light RED / YELLOW / BLUE 230V AC - 03 Nos. (v) Indication Lamp 22mm Dia Color Red 240V AC (ON) 2 Nos. (viii) Indication Lamp 22mm Dia Color Green 240V AC (OFF) 2 Nos. (ix) Indication Lamp 22mm Dia Color Amber 240V AC (trip) 2 Nos. (x) Indication Lamp 22mm Dia Color Red 24V DC ( DC ON) 1 Nos.(xi) Push Button Color Red with NC Elements 3 Nos. |
| 4 | (xii) Push Button Color Green with NO Elements 3 Nos.(xiii) DC Ammeter 1 Nos. (xiv) DC Voltmeter 1 Nos. (xv) Emergency Stop Push Buttion 1 Nos. (xvi) MCB 6A SP 10KA 9 Nos.(xvii) MCB 16A SP 10KA 1 Nos. (xviii) MCB 16A DP 10KA 2 Nos. (xix) MCB 6A FP 10KA 1 Nos.(xx) Voltage Monitoring Relay 1 Nos.(xxi) Aux. Contactor with Add on Block 2NO+2NC 240V AC 3 Nos. (xxii) Aux.Relay With Base 3 C/O 24V DC 3 Nos. (xxiii) Battery charger I/P-230V AC O/P 24V DC 1 Nos. (xxiv) LED bulb with Fitting 230V AC 2 Nos. (xxv) Door Switch ON/OFF 2 Nos. (d) MISCELLANEOUS:-Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC,Control Wire, Power Wire, Copper Thimbles, Panel Locks, I-Hooks, PVCTape, Insulators E-type, L-Type , Round Type, MCB Chanel, Pvc Chanel,Connector Chanel, Connectors etc.-1 Lot 10. Terminal block - 4 |
| 5 | Supply installing testing and commissioning factory made and tested, CPRI approved AMF panel for 100 KVA DG set, outdoor type, double door operated, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mm CRCA mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated Al. bus bar 1500 Amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCB with suitable capacity of Al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments and and comprising of the following including necessary excavation, PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size all as standard practice of manufacturer specifications with the following accessories:- Location: Officer mess area |
| 6 | INCOMER-1 & 2 (MAIN & DG) FOR 100 KVA DG SET:(a) BUSBARS: 315A TPN 415Volts 3Phase 4 Wire Color Coaded Aluminium busbars- 1 Lot(b). MCCB 200A FP EDO 36KA Microprocessor Based and power contactor 200Amps 4pole 36KA - 2 Nos. (c) AMF Relay (econ) 1 Nos. (i). Digital Ammeter 1 Nos. (ii). Digital Voltmeter 1 Nos. (iii). CT 100/5A CL1 10VA 1 Nos. (iv). Phase Indication Light RED / YELLOW / BLUE 230V AC - 03 Nos. (v) Indication Lamp 22mm Dia Color Red 240V AC (ON) 2 Nos. (viii) Indication Lamp 22mm Dia Color Green 240V AC (OFF) 2 Nos. (ix) Indication Lamp 22mm Dia Color Amber 240V AC (trip) 2 Nos. (x) Indication Lamp 22mm Dia Color Red 24V DC ( DC ON) 1 Nos.(xi) Push Button Color Red with NC Elements 3 Nos. |
| 7 | (xii) Push Button Color Green with NO Elements 3 Nos.(xiii) DC Ammeter 1 Nos. (xiv) DC Voltmeter 1 Nos. (xv) Emergency Stop Push Buttion 1 Nos. (xvi) MCB 6A SP 10KA 9 Nos.(xvii) MCB 16A SP 10KA 1 Nos. (xviii) MCB 16A DP 10KA 2 Nos. (xix) MCB 6A FP 10KA 1 Nos.(xx) Voltage Monitoring Relay 1 Nos.(xxi) Aux. Contactor with Add on Block 2NO+2NC 240V AC 3 Nos. (xxii) Aux.Relay With Base 3 C/O 24V DC 3 Nos. (xxiii) Battery charger I/P-230V AC O/P 24V DC or as per existing - 1 Nos. (xxiv) LED bulb with Fitting 230V AC 2 Nos. (xxv) Door Switch ON/OFF 2 Nos. (d) MISCELLANEOUS:-Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC,Control Wire, Power Wire, Copper Thimbles, Panel Locks, I-Hooks, PVCTape, Insulators E-type, L-Type , Round Type, MCB Chanel, Pvc Chanel,Connector Chanel, Connectors etc.-1 Lot |
| 8 | Supply installing testing and commissioning factory made and tested, CPRI approved AMF panel for 82.5 KVA DG set, outdoor type, double door operated, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mm CRCA mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated Al. bus bar 1500 Amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCB with suitable capacity of Al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments and and comprising of the following including necessary excavation, PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size all as standard practice of manufacturer specifications with the following accessories:-Location: Transmitter area |
| 9 | INCOMER-1 & 2 (MAIN & DG) FOR 82.5 KVA DG SET:(a) BUSBARS: 200A TPN 415Volts 3Phase 4 Wire Color Coded Aluminium busbars- 1 Lot(b). MCCB 160A FP EDO 36KA Microprocessor Based and power contactor 160Amps 4pole - 2 Nos. (c) AMF Relay (econ) 1 Nos. (i). Digital Ammeter 1 Nos. (ii). Digital Voltmeter 1 Nos. (iii). CT 100/5A CL1 10VA 1 Nos. (iv). Phase Indication Light RED / YELLOW / BLUE 230V AC - 03 Nos. (v) Indication Lamp 22mm Dia Color Red 240V AC (ON) 2 Nos. (viii) Indication Lamp 22mm Dia Color Green 240V AC (OFF) 2 Nos. (ix) Indication Lamp 22mm Dia Color Amber 240V AC (trip) 2 Nos. (x) Indication Lamp 22mm Dia Color Red 24V DC ( DC ON) 1 Nos.(xi) Push Button Color Red with NC Elements 3 Nos. |
| 10 | (xii) Push Button Color Green with NO Elements 3 Nos.(xiii) DC Ammeter 1 Nos. (xiv) DC Voltmeter 1 Nos. (xv) Emergency Stop Push Buttion 1 Nos. (xvi) MCB 6A SP 10KA 9 Nos.(xvii) MCB 16A SP 10KA 1 Nos. (xviii) MCB 16A DP 10KA 2 Nos. (xix) MCB 6A FP 10KA 1 Nos.(xx) Voltage Monitoring Relay 1 Nos.(xxi) Aux. Contactor with Add on Block 2NO+2NC 240V AC 3 Nos. (xxii) Aux.Relay With Base 3 C/O 24V DC 3 Nos. (xxiii) Battery charger I/P-230V AC O/P 24V DC or as per existing - 1 Nos. (xxiv) LED bulb with Fitting 230V AC 2 Nos. (xxv) Door Switch ON/OFF 2 Nos. (d) MISCELLANEOUS:-Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC,Control Wire, Power Wire, Copper Thimbles, Panel Locks, I-Hooks, PVCTape, Insulators E-type, L-Type , Round Type, MCB Chanel, Pvc Chanel,Connector Chanel, Connectors etc.-1 Lot |
| 11 | Supply installing testing and commissioning factory made and tested, CPRI approved AMF panel for 62.5 KVA DG set, outdoor type, double door operated, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mm CRCA mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated Al. bus bar 1500 Amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCB with suitable capacity of Al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments and and comprising of the following including necessary excavation, PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size all as standard practice of manufacturer specifications with the following accessories:-Location: AFNET, Old ATC & Base Ops/955 area |
| 12 | INCOMER-1 & 2 (MAIN & DG) FOR 62.5 KVA DG SET:(a) BUSBARS: 160A TPN 415Volts 3Phase 4 Wire Color Coded Aluminium busbars- 1 Lot(b). MCCB 125A FP EDO 36KA Microprocessor Based and power contactor 125Amps 4pole - 2 Nos. (c) AMF Relay (econ) 1 Nos. (i). Digital Ammeter 1 Nos. (ii). Digital Voltmeter 1 Nos. (iii). CT 100/5A CL1 10VA 1 Nos. (iv). Phase Indication Light RED / YELLOW / BLUE 230V AC - 03 Nos. (v) Indication Lamp 22mm Dia Color Red 240V AC (ON) 2 Nos. (viii) Indication Lamp 22mm Dia Color Green 240V AC (OFF) 2 Nos. (ix) Indication Lamp 22mm Dia Color Amber 240V AC (trip) 2 Nos. (x) Indication Lamp 22mm Dia Color Red 24V DC ( DC ON) 1 Nos.(xi) Push Button Color Red with NC Elements 3 Nos. |
| 13 | (xii) Push Button Color Green with NO Elements 3 Nos.(xiii) DC Ammeter 1 Nos. (xiv) DC Voltmeter 1 Nos. (xv) Emergency Stop Push Buttion 1 Nos. (xvi) MCB 6A SP 10KA 9 Nos.(xvii) MCB 16A SP 10KA 1 Nos. (xviii) MCB 16A DP 10KA 2 Nos. (xix) MCB 6A FP 10KA 1 Nos.(xx) Voltage Monitoring Relay 1 Nos.(xxi) Aux. Contactor with Add on Block 2NO+2NC 240V AC 3 Nos. (xxii) Aux.Relay With Base 3 C/O 24V DC 3 Nos. (xxiii) Battery charger I/P-230V AC O/P 24V DC or as per existing - 1 Nos. (xxiv) LED bulb with Fitting 230V AC 2 Nos. (xxv) Door Switch ON/OFF 2 Nos. (d) MISCELLANEOUS:-Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC,Control Wire, Power Wire, Copper Thimbles, Panel Locks, I-Hooks, PVCTape, Insulators E-type, L-Type , Round Type, MCB Chanel, Pvc Chanel,Connector Chanel, Connectors etc.-1 Lot |
| 14 | Supply installing testing and commissioning factory made and tested, CPRI approved AMF panel for 30 KVA DG set, outdoor type, double door operated, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mm CRCA mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated Al. bus bar 1500 Amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCB with suitable capacity of Al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments and and comprising of the following including necessary excavation, PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size all as standard practice of manufacturer specifications with the following accessories:-Location: Logistics area |
| 15 | INCOMER-1 & 2 (MAIN & DG) FOR 30 KVA DG SET:(a) BUSBARS: 100A TPN 415Volts 3Phase 4 Wire Color Coded Aluminium busbars- 1 Lot(b) MCCB 100A FP EDO 36KA Microprocessor Based and power contactor 100Amps 4pole - 2 Nos. (c) AMF Relay (econ) 1 Nos. (i). Digital Ammeter 1 Nos. (ii). Digital Voltmeter 1 Nos. (iii). CT 100/5A CL1 10VA 1 Nos. (iv). Phase Indication Light RED / YELLOW / BLUE 230V AC - 03 Nos. (v) Indication Lamp 22mm Dia Color Red 240V AC (ON) 2 Nos. (viii) Indication Lamp 22mm Dia Color Green 240V AC (OFF) 2 Nos. (ix) Indication Lamp 22mm Dia Color Amber 240V AC (trip) 2 Nos. (x) Indication Lamp 22mm Dia Color Red 24V DC ( DC ON) 1 Nos.(xi) Push Button Color Red with NC Elements 3 Nos. |
| 16 | (xii) Push Button Color Green with NO Elements 3 Nos.(xiii) DC Ammeter 1 Nos. (xiv) DC Voltmeter 1 Nos. (xv) Emergency Stop Push Buttion 1 Nos. (xvi) MCB 6A SP 10KA 9 Nos.(xvii) MCB 16A SP 10KA 1 Nos. (xviii) MCB 16A DP 10KA 2 Nos. (xix) MCB 6A FP 10KA 1 Nos.(xx) Voltage Monitoring Relay 1 Nos.(xxi) Aux. Contactor with Add on Block 2NO+2NC 240V AC 3 Nos. (xxii) Aux.Relay With Base 3 C/O 24V DC 3 Nos. (xxiii) Battery charger I/P-230V AC O/P 24V DC or as per existing - 1 Nos. (xxiv) LED bulb with Fitting 230V AC 2 Nos. (xxv) Door Switch ON/OFF 2 Nos. (d) MISCELLANEOUS:-Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC,Control Wire, Power Wire, Copper Thimbles, Panel Locks, I-Hooks, PVCTape, Insulators E-type, L-Type , Round Type, MCB Chanel, Pvc Chanel,Connector Chanel, Connectors etc.-1 Lot |
| 17 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 95 Sqmm 3.5 core with necessary fixing arrangements such as lungs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 18 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 16098-2 of size 65 mm outer dia for cable protection on pole/wall/floor or in trenches and drain /culvert etc. complete with necessary clamp, nuts, bolts, washers, sockets if required all as specified and directed. |
| 19 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed. |
| 20 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 21 | Removing excavated material (soil) exc 50 m n.exc 250 m and depositing where as directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 22 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I(2009)Note: Unit rate quoted shall be deemed to be included the following (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 23 | M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 25x4mm galvanised iron strip all as directed by Engr-in-charge. |
| 24 | Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed. |
| 25 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 26 | Material and Labour for 100mm thick plain cement concrete 1:2:4 type B2 using 40mm graded granite stone aggrgate as floor and other similar type of work, laid in panels and finishing cement concrete surface even and smooth Without using extra cement, complete all as specified and as directed. |
| 27 | Schedule of Credit (Minus) Rs.6592.00 NOTE: Bidder shall insert credit amount of Rs. 6592.00 as rate in Green field under Col-13. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer