Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56962254

Tender For Special Repair To Lt Panels And Connected Items At Pyro, Pinaka, Nag Mixture Bldg, Magazine Area And Apb Bldg In Hemrl Pune

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Sep 2026
16 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Lt Panels And Connected Items At Pyro, Pinaka, Nag Mixture Bldg, Magazine Area And Apb Bldg In Hemrl Pune

BOQ

Name of Work:- SPECIAL REPAIR TO LT PANELS AND CONNECTED ITEMS AT PYRO, PINAKA, NAG MIXTURE BLDG, MAGAZINE AREA AND APB BLDG IN HEMRL PUNE
Sl. No. Item Description
1Taking out old serviceable/unserviceable LT Panel/Capacitor panel of any description or capacity keeping aside in safe custody for schedule of Credit complete all as specified and directed
2Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1200 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-Incoming: (a) ACB adjustable type with thermal magnetic release 4 pole, 800A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 Nos, (c) MCCB 4P, 125 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (d) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 630/5 - 01 Nos, (e) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (f) LED phase indicator (R,Y & B) - 01 Set. (Pyro Sub Stn)
3Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1200 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-Incoming: (a) ACB adjustable type with thermal magnetic release 4 pole, 800A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (c) MCCB 4P, 315 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (d) MCCB 4P, 250 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos (e) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 630/5 - 01 Nos, (e) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (f) LED phase indicator (R,Y & B) - 01 Set. (Nag Mixture Bldg)
4Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1200 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-Incoming: (a) ACB adjustable type with thermal magnetic release 4 pole, 800A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (c) MCCB 4P, 320 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (d) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (e) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (f) MCCB 4P, 100 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos (g) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 630/5 - 01 Nos, (h) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (h) LED phase indicator (R,Y & B) - 01 Set. (Sub Stn No 34)
5Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board Indoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 2 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1000 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-Incoming: (a) MCCB adjustable type with thermal magnetic release 4 pole, 630 A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (c) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (d) MCCB 4P, 63 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 Nos (e) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 500/5 - 01 Nos, (f) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (f) LED phase indicator (R,Y & B) - 01 Set. (Pinaka Bldg)
6Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1200 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-Incoming: (a) ACB adjustable type with thermal magnetic release 4 pole, 800A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (c) MCCB 4P, 250 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (d) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (e) MCCB 4P, 125 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (f) MCCB 4P, 100 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos (g) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 630/5 - 01 Nos, (h) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (h) LED phase indicator (R,Y & B) - 01 Set. (Sub Stn No 19)
7Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1000 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-Incoming: (a) MCCB adjustable type with thermal magnetic release 4 pole, 630 A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 315 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (c) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (d) MCCB 4P, 125 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos (e) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 500/5 - 01 Nos, (f) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (g) LED phase indicator (R,Y & B) - 01 Set. (Sub Stn No 37))
8Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 185 Sqmm 3.5 Core in trenches or fixed on wall/floor/poles in replacement complete all as specified and directed
9All as per item No 08 but 240 Sqmm 3.5 Core complete all as specified and directed
10All as per item No 08 but 300 Sqmm 3.5 Core complete all as specified and directed
11Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of LT under ground cable and getting out in the following type of earth stata complete all as specified and as directed by Engr-in charge :-a) Soft/ loose Soil
12(b) Hard / dense soil
13Supplying and laying un-reinforced precast concrete cable cover, Class HV, Type 1, flat, size 250mmx l50mm x 40m complete all as specified and directed by Engr-in-Charge .
14Supplying, spreading, leveling and well ramming in layers not exceeding 20 cm in height stone crushed Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge .
15Material and Labour for returning/filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres complete all as specified and directed by Engr-in-Charge.
16Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge .
17Material and labour for earthing in repairs complete with galvanised steel earth plate electrode 60 × 60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in charge .
18Supply and fix in replacement GI strip 32mmx 6mm burried in ground complete all as specified and directed by Engr-in charge . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56962254
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 01-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Lt Panels And Connected Items At Pyro, Pinaka, Nag Mixture Bldg, Magazine Area And Apb Bldg In Hemrl Pune
Basic Detail
Tender No GERD/PSN/TOKEN/31 OF 2026-27
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 11 Aug 2026
Submission Date 01 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 86000
Exemption Available
Document List
Tendernotice_1 (7).pdf
458eea61-1a09-4046-9c0d-2b8dec8f7d50.html
8725.pdf
BOQ_878452.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (7).pdf

html

458eea61-1a09-4046-9c0d-2b8dec8f7d50.html

pdf

8725.pdf

xls

BOQ_878452.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders