Tender For Repair/Replacement Of Defective Flame Proof Exhaust Fan Fittings/Fixtures Alongwith Wiring & Connected Items At Various Buildings, Workshop, Pol Store And Paint Store At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam.
Tender Overview
Project Description
Tender for Repair/Replacement Of Defective Flame Proof Exhaust Fan Fittings/Fixtures Alongwith Wiring & Connected Items At Various Buildings, Workshop, Pol Store And Paint Store At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Aug-2026 | Corrigendum 01 | BOQ | 01-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M & L for surface wiring with 2 x 2.5 sqmm (Nominal area) single core PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable drawn through in and including ERW stove enamelled steel Conduit medium grade with junction box of suitable size with connector for fixing of all FP fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. Note: (a) Two run of cable with one run of earth wire and one run of steel conduit will be measured as one length. (b) Working height upto roof level of wksp buildings only. |
| 2 | All as per item No. 1.00 above, but cable of size 2 x 4.0 sqmm and earth wire 1 x 4.0 sqmm |
| 3 | All as per item No. 1.00 above, but cable of size 4 x 10.0 sqmm and earth wire 2 x 10 sqmm |
| 4 | S&F Flame Proof weather proof rotary switch with separate cable termination box including dismantling and taking down all specified and directed. |
| 5 | S&F Flame Proof weather proof 3 way junction box 100 mm dia incl dismantling and taking down all specified and directed. |
| 6 | Fixing only LED flameproof fitting complete with retro LED twin T8 tube 20W incl dismantling taking down unsv one any type all as specified and directed. Note:- LED flameproof fitting will be issued under Schedule 'B' free fixing. |
| 7 | S&F LED flameproof highbay light fitting 70W with heat resistant toughned glass at roof truss level of wksp buildings and other places including dismantling taking down unsv one any type all as specified and directed. |
| 8 | S&F LED flameproof highbay light fitting 150W with heat resistant toughned glass at roof truss level of wksp buildings and other places incl dismantling taking down unsv one any type all as specified and directed. |
| 9 | Fixing only LED flameproof highbay light fitting 200w with heat resistant toughned glass at roof truss level of wksp buildings and other places incl dismantling taking down unsv one any type all as specified and directed.Note:- LED flameproof highbay light fitting will be issued under Schedule 'B' free fixing. |
| 10 | M&L for Complete servicing of flameproof exhaust fan of any size in situ after dismanting taking down from any wall height incl necessary spares parts required for smooth functioning/ winding if reqd & testing upto satisfaction level complete all as specified and directed. |
| 11 | S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. |
| 12 | S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. |
| 13 | S&F MCB, three Pole, 40 to 63 amps, 415 Volts incl dismantling taking down unsv one all as specified and directed. |
| 14 | S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed. |
| 15 | S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismantling taking down unsv one all as specified and directed. |
| 16 | S&F Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. |
| 17 | S&F MCCB, 25KA, 4 pole, with thermal magnetic trip unit, rated current 125amps complete with spider link incl dismantling taking down unsv one all as specified and directed (Suitable for MCCB incomer DB). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender