Tender For Upgradation Of Phc Massu By Way Of Electrification work construction Of Septictank & Bio Medical Waste Shed.

Issued by Government Departments · Kishtwar, Jammu and Kashmir
Tender Value
15 Lakhs
Estimated cost
Bid Submission
26 Aug 2026
11 days left
EMD
30000
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kishtwar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Phc Massu By Way Of Electrification work construction Of Septictank & Bio Medical Waste Shed.

BOQ

Name of Work:- Upgradation of PHC Massu by way of electrification work/Constt of SepticTank & Bio Medical waste shed.
Sl. No. Item Description
1Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil
2Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.2.6.1 All kinds of soil :
3Dumping stone including cost of stones.in Horizontal on level
4Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
5Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
6Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
7Centering and shuttering including strutting, propping etc. and removal of form for:5.9.1 Foundations, footings, bases of columns etc. for mass concrete.
8Centering and shuttering including strutting, propping etc. and removal of form for:Lintel, beams, plinth beams, girders, bressumers and cantilevers.
9Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars, piers, abutments, posts and struts.
10Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms.
11Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
12Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc.complete. 50 mm thick with 20mm nominal size stone aggregate.
13Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 500x500 mm
14Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
15Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
16Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Kiln seasoned and chemically treated hollock wood
17Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second class kail wood
18Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
19Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
20Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.5 0.63 mm thick with zinc coating not less than 275 gram/m2
21Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.12.4.3 0.50 mm thick with zinc coating not less than 275 gram/m2
22Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:4.4.6 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
23Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone
2412mm Cement plaster of mix:1 : 6 ( 1 cement : 6 coarse sand)
25Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRIS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required
26Wiring for light/ power plug with 282 sq. mm FRIS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 xg. mm FRES PVC insulated copper conductor single core cable for loop earthing as required.
27Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
28Supplying and drawing following sizes of FRES PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1x 1.5 sq.mm
29Supplying and fixing of following sizes of medium classPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
30Supplying and fixing following modular switch/ socket on the existing modular plate de switch box including connections but excluding modular plate etc. as required. 5/6 A switch
31Supplying and fixing following modular switch/ socket on the existing modular plate de switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
32Supplying and fixing following modular switch/ socket on the existing modular plate de switch box including connections but excluding modular plate etc. as required.15/16 Amp switch
33Supplying and fixing following modular switch/ socket on the existing modular plate de switch box including connections but excluding modular plate etc. as required.6 pin 15/16 socket outlet
34Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as reruired.
35Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
36Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
37Supplying & fixing of following way single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way (Double door) SPN Type
38Supplying and fixing 5 A to 32 A rating, 240/415 V. 10 kA.\\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole
39Supplying and fixing 5 A to 32 A rating, 240/415 V. 10 kA.\\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.single pole and neutral 63 Amp
40Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable: & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable (steelrope), cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.1200mm Sweep BEE 3 Star rated (service value >-5,0 to.< (5.5) 1200mm Sweep BEE 3 Star rated (service value >-5,0 to.< (5.5)
41Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver, System lumen efficacy ≥ 110 Im/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. p ≥0.95, CRI >80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K /4000°K/ 5700°K / 6000°K (As per ANSI Bin), Maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embosing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LMS80 ) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge20/22 watt LED 4 feet with min.lumen output (2000- 2200)
42Supplying and Fixing of 16 sq. mm twin core aluminium cable all along the wall surface unarmoured.
43Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete.
44Sand, for an average lead of 10km by MT & 500 mtr by HL
45Stone aggregate below 40 mm nominal size for an average lead of 70km by MT & 500 mtr by HL
46Steel for an average lead of 10km by MT & 500 mtr by HL
47Cement for an average lead of 10 Km by MT & 500 mtr by HL
48Bricks for an average lead of 240 km by MT & 500 mtr by HL
49Stone for an average lead of 500 mtr by HL Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56959213
AUTHORITY Government Departments
TENDER VALUE 15 Lakhs
LAST DATE 26-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgradation Of Phc Massu By Way Of Electrification work construction Of Septictank & Bio Medical Waste Shed.
Basic Detail
Tender No e-NIT No. 32 of 2026-27 Dated 11-08-2026
Bidding Type Tender
Location
City Kishtwar
State Jammu and Kashmir
Key Dates
Publish Date 11 Aug 2026
Submission Date 26 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 15 Lakhs
Tender Fee 600
EMD 30000
Exemption Not Available
Document List
BOQ_1065817.xls
f442e06a-9c09-42b1-9445-891dbb2d3d96.html
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1065817.xls

html

f442e06a-9c09-42b1-9445-891dbb2d3d96.html

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders