| Sl. No. | Item Description |
| 1 | S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc. as reqd. 1 or 2 modules |
| 2 | S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc. as reqd. 6 module |
| 3 | S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc. as reqd. 8 module |
| 4 | S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including, painting etc. |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sqmm. |
| 6 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sqmm. |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sqmm. |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 6 sqmm. |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 10 + 1 x 6 sqmm earth wire. |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group c. |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch. |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet. |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amps switch. |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet. |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push. |
| 16 | S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. |
| 17 | S/F of brass batten/angle holder including connections etc. as reqd. |
| 18 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | S/F of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 20 | S/F of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm |
| 21 | Providing and fixing of 48\\" (1200 mm) ceiling fan with all accessories and making connection etc as reqd. at site (Havells/ CG / Orient/ Usha/Almonard/DJB approved) |
| 22 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (DSR 2021 civil 15.7.4 ) |
| 23 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 2021 civil code 4.1.8) |
| 24 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door |
| 25 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 26 | Supplying and fixing following 100 amp, four pole, 415 volts, FP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 27 | Supplying and fixing of bell buzzer suitable for single phase 220 volt i/c making connection etc. as reqd. at site |
| 28 | Installation, testing and commissioning of 48\\" ceiling fan including wiring the down rods standard length single core copper conductor cable etc. as reqd. at site |
| 29 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE alumium conductor cable of 1.1 KV grade as required 4 x 16 sq. mm |
| 30 | Installation, testing and commissioning of LED fitting of all type complete with all accessories directly on ceiling wall including connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and earthing etc. as reqd. at site |
| 31 | Supplying of 100 watt flood light fitting pressured dia cast housing with IP65 protection efficient high 220-240V output emitter LED for better distribution with dimension 447 X 163 x 327 mm and 6500 colour with lumens 15500 with all accessories etc. as etc. as reqd. at site.( Make : Crompton/Havells/DJB approved ) |
| 32 | Installation of LED light flood light 100 Watts with all safety measures with the help of skilled labour/technician as required. |
| 33 | Supplying and fixing of angle frame of suitable size (50\\" x 50\\") including excavation and repairing the same etc. as reqd. at site. |
| 34 | Supplying and fixing of 32 mm dia X 1.80 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 1 No. 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. This also include supply & fixing of 2 Nos, 32 mm dia X 1.8.0 metres long G.I. pipe with bend for junction box. |
| 35 | Supplying of 2\\" HDPE flexible PVC pipe complete with all accessories i/c jointing and making good the same etc. as reqd. at site |
| 36 | Supply of SMC junction boxes anti-corrosive water resistant, UV protected, High temp resistant, weather able and suitable for all kinds of climatic conditions. Self-colour fire retardant and high dielectric strength maintenance free. Make: Bajaj / Hensel / Syntex/Other DJB approved make |
| 37 | Higher Wattage Decorative ultra slim aluminum LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. 36 watt LED 6500 K |
| 38 | Supply of XLPE insulated, PVC sheathed Al.conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 4 x 16 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved. |
| 39 | Providing of ( 200 mm ) exhaust fan with all accessories and making connection etc. as reqd. at site ( Havells/ CG / Orient/ Usha/Almonard/DJB approved ) |
| 40 | Supply, installation, testing and commissioning 3' x 3' feet size cubical panel wall mounted 3 phase 4 wire system and dust proofed the cubical panel made of 16 gauge CRCA sheet supported on angle channel. The door shall be made out of 16 gauge CRCA sheet duly painted and having aluminium bus bar the 25 x 10 size following. 3 output (1output per phase) and suitable for three phase supply power supply connections by fixing the incoming - 125 amp MCCB - 1 No. and outgoing 100 Amp - 1 No., etc. as reqd. |
| 41 | New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. 100 watt |
| 42 | Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cut off and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (outdoor ambient temperature). Non Inverter Type 1.5 TR with fixed speed 5 Star BEE rating ( DSR 2025 32.1.2 ) |
| 43 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. . The system shall be able to operate up to 50 OC (outdoor ambient temperature). 1.5 TR with 5 Star BEE Rating ( DSR 2025 32.2.3 ) |
| 44 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 45 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 46 | Installation of LED light 100 Watts on street light Pole after erection with all safety measures with the help of skilled labour/technician as required. |
| 47 | Loading, unloading, cartage and transportation charges for the above pole upto the side i/c charges of heavy labour etc. as per site requirement. |
| 48 | Testing and commission of complete work in the presence of Engineer-in-charge with full satisfaction. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender