Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #56951678

Tender For Cable Connection Of Dg Set In Newly Constructed Building Of The Dept. Of Molecular & Human Genetics And Electrical Renovation Work Including Replacement Of Old Power Sockets In Algal Culture Room, Old Building In Department Of Botany, B.H.

Issued by Boards / Undertakings / PSU · Varanasi, Uttar Pradesh
Tender Value
2.78 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
0 days left
EMD
5570
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Cable Connection Of Dg Set In Newly Constructed Building Of The Dept. Of Molecular & Human Genetics And Electrical Renovation Work Including Replacement Of Old Power Sockets In Algal Culture Room, Old Building In Department Of Botany, B.H.U.

BOQ

Name of Work:- Cable connection of DG Set in Newly constructed building of the Dept. of Molecular & Human Genetics and Electrical renovation work including replacement of old Power Sockets in Algal Culture Room, Old Building in Department of Botany, B.H.U.
Sl. No. Item Description
1Electrical Work for Dept. of Molecular & Human Genetics.
2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)
3Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm
4Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
5Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
6Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
7Dismantling and removing the existing LT power cable of given size from open cable duct/trench, including disconnecting from both ends, careful retrieval without damaging reusable cable (where required), removal of cable cleats/clamps, dressing, coiling, stacking at the designated location or as directed by the Engineer-in-Charge, including all labour, tools, tackles and incidental charges, complete.
8Supply of 1.1 kV grade XLPE insulated, PVC sheathed, armoured, aluminium conductor,conforming to relevent IS, complete as required. 3.5x95sqmm Aluminium Cable
9Supply, installation, testing and commissioning of On Load Changeover Switch (Manual), 4 Pole, 200 Ampere, suitable for 415 V AC, 50 Hz, three-phase four-wire system, enclosed in a sheet steel powder-coated enclosure with front operating handle, providing safe transfer of load between two power sources without interrupting the load.
10Electrical Work for Algal Culture Room, Dept. of Botany.
11Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
12Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sqmm + 1x1.5 sqmm earth wire
13Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x4.0sqmm
14Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.6x4.0sqmm
15Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 20mm
16Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 25mm
17Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x6.0 sqmm + 1x6.0 sqmm earth wire
18Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4x10 sqmm + 2x6 sq mm earth wire
19Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
20Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
21Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
22Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way (4 + 18), Double door
23Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPMCB (5-32A)
24Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
25Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
26Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB.
27Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
28Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
29Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
30Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
31Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
32Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 ½ x 25 sq. mm (28 mm)
33Supply of 1.1 kV grade XLPE insulated, PVC sheathed, armoured, aluminium conductor,conforming to relevent IS, complete as required. 3½ core × 25 sq. mm cable
34Providing and fixing 2' × 2' LED light fittings, suitable for recessed / surface mounted / suspended installation, complete with aluminium housing, high efficiency LEDs, glare-free diffuser/optical system, constant current electronic LED driver, suitable for operation on 230 V, 50 Hz AC supply, power factor ≥ 0.90, CRI ≥ 80, colour temperature 4000K–6500K, system efficacy not less than 100 lm/W, complete with all mounting accessories, suspension arrangement wherever required, connections, testing and commissioning, as required, Make- Crompton/Wipro/Phillips
35Providing and fixing 400 mm sweep energy efficient wall mounted fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, complete with oscillating mechanism, speed control arrangement, aerodynamically designed blades, protective guard and all necessary wall mounting accessories, including connection, testing and commissioning, complete as required. Make- Crompton/Bajaj/Usha
36Providing and fixing of 18 Watt Round light fitting with extruded aluminium housing/body, complete with high efficiency LEDs, integral electronic driver, polycarbonate diffuser, suitable for 230 V, 50 Hz AC, having system efficacy not less than 100 lm/W, CRI ≥ 80, power factor ≥ 0.90, correlated colour temperature (CCT) 5700–6500 K, with suitable surge protection, complete with mounting accessories, connection, testing and commissioning, complete as required. Make- Crompton/Wipro/Phillips.
37Dismantling of old existing wiring, TPN switch and associated accessories, and relocation/reinstallation of TPN switch at suitable location as per site requirement and direction of Engineer-in-Charge, including necessary connection, dressing of cables, minor civil works, testing and commissioning complete.”
38Buyback of existing old/unserviceable wiring, cables, conduits and associated electrical materials from site after dismantling, including safe removal, loading, transportation, and proper accounting as per direction of Engineer-in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56951678
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.78 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Banaras Hindu University
Work Description Tender for Cable Connection Of Dg Set In Newly Constructed Building Of The Dept. Of Molecular & Human Genetics And Electrical Renovation Work Including Replacement Of Old Power Sockets In Algal Culture Room, Old Building In Department Of Botany, B.H.U.
Basic Detail
Tender No UED/2026/05082026-1
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 11 Aug 2026
Submission Date 19 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 2.78 Lakhs
Tender Fee 500
EMD 5570
Exemption Not Available
Document List
BOQ_968510.xls
f2fbf33c-2ae1-41f4-820f-bcc693ebd63b.html
tenderdocument06.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
xls

BOQ_968510.xls

html

f2fbf33c-2ae1-41f4-820f-bcc693ebd63b.html

pdf

tenderdocument06.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail