Agriculture Government Departments Closing in 10 days TDR #56951598

Tender For Construction Work Of Multi-Level Parking In Kanda (Bageshwar)

Issued by Government Departments · Bageshwar, Uttarakhand
Tender Value
5.40 Crore
Estimated cost
Bid Submission
25 Aug 2026
10 days left
EMD
10.82 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bageshwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Work Of Multi-Level Parking In Kanda (Bageshwar)

BOQ

Name of Work:- Construction work of Multi-level Parking in Kanda (Bageshwar)
Sl. No. Item Description
1Excavation in soil in hilly are by manual means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5m and a lead upto 20m. As per drawing and technical specification clause 1603.1
2Extra for every additional lift of 1.5m or part thereof.
3Extra for every additional lift of 1.5m or part thereof.
4Extra for every additional lift of 1.5m or part thereof.
5Diluting and injecting chemical emulsion (chlorpyriphos/Lindane E.0 20% with 1%concentration) at the rate of one litre per hole at 300 mm c/c to all the horizontal and vertical surface of the excavation made for the foundation of the building, soil under floor,apron, back fill material and along all the faces of the walls for PRECONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) as per IS:6313 Part-II. (Plinth area of building shall be measurd for payment.)
6Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
8Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12..5 mm nominal size).
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
10Reinforced cement concrete work in walls (any thickness), including attached , pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20. mm nominal size).
11Steel reinforcement for R.C.C. work) including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bar
12Centering and shuttering including strutting,propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
13Centering and shuttering including strutting,propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
14Centering and shuttering including strutting,propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
15Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand
17Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand
18Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, Area of slab over 0.50 sqm
19Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screw
20Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
21Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
22Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
23Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessaryscrews etc. complete. Single rubber stopper
24Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15 x 10 x 10 cm of CC 1:3:6 (1 Cement: 3 Coarse sand : 6 graded stone aggregate 20mm nominal size)
25Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
26Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4mm thick glass panels
27Providing and laying polished granite stone flooring in required design and patterns, in linear as well as curvilinear proportions of the building all complete as per the architectural drawings with 18mm th. Stone slab over 20mm average th base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing , curing and polishing etc. all complete as specified and as directed by the engineer-in-charge. ---polished granite stone slab of colour black, cherry/Ruby red or equivalent
28Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints With white cement and matching pigment etc., complete.
3012 mm thick cement plaster in 1:6 ( 1 cement and 6 fine sand)
3115 mm cement plaster on the rough side of single or half brick wall of mix: 1:6 (1 cement: 6 fine sand)
32Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
33Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement prime
34Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 Itr/10sqm over and including priming coat of exterior primer applied © 2.20 kg/10 sqm)
35Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over anunder coat of suitable shade with ordinary paint of approved brand and manufacture
36Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymermixed slurry.
37Designing, fabricating, testing, installing and fixing panels of aluminium composite panel cladding, with open grooves for liner as well as curvilinear portions of the building for all heights and all levels etc. including: (a) Structural analysis and design and preperation of shop drawings for pressure equilisation or rain screen principal as required propoer drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panels cladding in PAN shape in mettalic colour of approved shadesd made out of 4mm th. aluminium composite panel material consisting of 3mm th. FR grade mineral, core sandwitched between two aluminium sheets c(each .5mm th.). the aluminium composite panel cladding shjeet shall be coil coated with Kynar 500 based PVDF/ on face #1 and polymer (service) coatong on face #2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicon sealant, backer rods etc. (c) The fastening brackets of alluminium alloy 6005 T5/MS with hot deep galvanised with seratons and serrated washers to arrest the wind load movement, fastners, SS 316 pins and anchor bolts of approved make in SS316, nylon seperators to prevent bymetalic contacts all complete to perform as per specification and drawing, the item includes the cost all material and labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved labratory, field test on the assembled working curtain wall with alluminium composite panel cladding, cleaning and protection of the curtain wall with alluminium composdite oanel cladding till the handing over of the building for occupation, based frame work forACP cladding is payable under the relevnt alluminium item. the contractor should provide the curtain wall with alluminium composite panel cladding having all the performance charecteristics all complete, as per architectural drawings, as per item description, as specified as per approved shop drawings and as directed by engineer in charge. However for the purpose of payment, only the actual area on the external face of the curtain wall with ACP cladding (including width of groove) shall be measured in sqm upto 2 decimal places.
38Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
39Providing and fixing ball bearings for rolling shutters
40Centering and shuttering including strutting,propping etc. Shelves (Cast in situ)
41Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
42Centering and shuttering including strutting,propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick
43Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
44WGSTLMIDTC Twin Control point wiring inPVC conduit, with modular type switch:
45Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor singlecore cable in surface / recessed medium classPVC conduit, 2 way modular switch, modular'plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FR PVC insulated copperconductor single core cable etc as required WGSTLPP2 Power plug wiring in PVCconduit (2x4 sq. mm)
46Wiring for light/power plug with 2x4 sq.mm FRPVC insulated copper conductor single corecable in surface/ recessed steel conduitalongwith 1 No 4 sq. mm FR PVC insulatedcopper conductor single core cable for loopearthing as required. WGSTLSB Circuit/ submain wiring in PVC conduit: Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
47Wiring for light/power plug with 2x4 sq.mm FRPVC insulated copper conductor single corecable in surface/ recessed steel conduitalongwith 1 No 4 sq. mm FR PVC insulatedcopper conductor single core cable for loopearthing as required. WGSTLSB Circuit/ submain wiring in PVC conduit: Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
48Wiring for light/power plug with 2x4 sq.mm FRPVC insulated copper conductor single corecable in surface/ recessed steel conduitalongwith 1 No 4 sq. mm FR PVC insulatedcopper conductor single core cable for loopearthing as required. WGSTLSB Circuit/ submain wiring in PVC conduit: Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
49Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. PVCCON S/F PVC conduit: 25 mm
50Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. MB S/F metal boxes: 75 mm X 75 mm X 60 mm deep
51Supplying and fixing following modular switch/socket on the existing modular plate & switchbox including connections but excludingmodular plate etc. as required. PTSWEB S/F modular type switch/ socket: 5/6 amps switch
52Supplying and fixing following modular switch/socket on the existing modular plate & switchbox including connections but excludingmodular plate etc. as required. PTSWEB S/F modular type switch/ socket: 3 pin 5/6 amp socket outlet
53Supplying and fixing following modular switch/socket on the existing modular plate & switchbox including connections but excludingmodular plate etc MODFREB S/F modular type electronic fanregulator:
54Supplying and fixing two module stepped typeelectronic fan regulator on the existing modularplate switch box including connections butexcluding modular plate etc. as required. LPACCPT S/F light plug point modular typeaccessories:
55Supplying and fixing suitable size GI box withmodular plate and cover in front on surface orin recess, including providing and fixing 3 pin5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required.(For light plugs to be used in non residentialbuildings). PPACCPT S/F power plug point modulartype accessories:
56Supplying and fixing suitable size GI box withmodular plate and cover in front on surface orin recess, including providing and fixing 6 pin5/6 & 15/16 amps modular socket outlet and15/16 amps modular switch, connection etc. asrequired. CREB S/F ceilling rose:
57Supplying and fixing 3 pin, 5 amp. ceilling roseon the existing junction box/ wooden blockincluding connection etc. as required BRHOLD S/F brass holder:
58Supplying and fixing brass batten/angle holderincluding connection etc. as required. ITCFFSUR ITC fluorescent fitting directly on surface:
59Installation, testing and commissioning of prewired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. ITCCFFC ITC ceiling fan with cover on fanbox:
60Installation, testing and commissioning ofceiling fan, including wiring the down rods ofstandard length (upto 30 cm) with 1.5 sq, mmFR PVC insulated, copper conductor, singlecore cable, including providing and fixingphenolic laminated sheet cover on the fan boxetc. as required. ITCEF450 ITC exhaust fan upto 450 mmsweep:
61Installation of exhaust fan upto 450 mm sweepin the existingopening, including making thehole to suit the size of the above fan, makinggood the damage, connection, testing,commissioning etc. as required. LOUSHEF Fixing louvers/shutters forexhaust fan:
62Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without B/RCCB/Isolator) Extra for fixing louvers/shutters complete withframe for a exhaust fan of all sizes. BOARD & DB'S PWTPMCBDB S/F TP MCB DB: 8 way (4+24), double door
63Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without B/RCCB/Isolator) Extra for fixing louvers/shutters complete withframe for a exhaust fan of all sizes. BOARD & DB'S PWTPMCBDB S/F TP MCB DB: 4 way (4+12), double door
64Supplying and fixing following rating, four pole,415 volts, isolator in the existing MCB DBcomplete with connections, testing and .commissoning etc. MCBTPIS S/F TP MCB isolator: as required. 63 amps
65Supplying and fixing 5 A to 32 A rating, 240/415V, 10 kA, \\"C\\" curve, miniature circuit breakersuitable for inductive load of following poles inthe existing MCB DB complete with connections, testing and commissioning etc. as required. MCBC S/F 'C' curve, SP MCB Single pole
66Earthing with G.I. earth plate 600 mm X 600mm X 6 mm thick including accessories, andproviding masonry enclosure with cover platehaving locking arrangement and watering pipeof 2.7 metre long etc.with charcoal/ coke andsalt as required.. EARGIPL G.I earth plate elctrode:
67Earthing with G.I. earth plate 600 mm X 600mm X 6 mm thick including accessories, andproviding masonry enclosure with cover platehaving locking arrangement and watering pipeof 2.7 metre long etc.with charcoal/ coke andsalt as required.. EARG125X6 S/L 25 mm x 5 mm G.I. earthstrip in ground:
68Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brushless direct current (BLDC) NOS. canopies shackle kit, safety roap, copper winding, power factor not ess then 0.9, service value (CM/M/W) MINIMUM 6.00, AIR DELIVERY MINIMUM 210 cum/min., 350 RPm (tolerance as per IS 374-2019), THD less than 10%, remote or electronic rgulator unit for speed control and all remaining acessories including safety pin, nut bolts, washers, temperature rise= 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required. 1200 mm sweep
69Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe; with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
70Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
71Providing and fixing soil , waste and vent pipes:S.C.I S&S pipe as per IS:1729 100 mm dia
72Providing and fixing soil , waste and vent pipes:S.C.I S&S pipe as per IS:1729 75 mm dia
73Providing and fixing PTMT soap Dish Holderhaving length of 138mm, breadth 102mm,height of 75mm with concealed fittingarrangements, weighing not less than 106 gms.
74Providind and fixing M.S.holder bat clamps ofapproved design to sand cast iron/cast iron(squn) pipe embedded in and including cementconcrete blocks 10x10x10cm of 1:2:4 mix(1cement :2coarse sand :4graded stoneaggregate 20mm nominal size ) including costof cutting holes and making good the walls etc: For 100 mm dia pipe
75Providind and fixing M.S.holder bat clamps ofapproved design to sand cast iron/cast iron(squn) pipe embedded in and including cementconcrete blocks 10x10x10cm of 1:2:4 mix(1cement :2coarse sand :4graded stoneaggregate 20mm nominal size ) including costof cutting holes and making good the walls etc: For 75 mm dia pipe
76Providing and fixing bend of required degreewith access door, insertion rubber washer 3mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 1729 100 mm diameter pipe
77Providing and fixing bend of required degreewith access door, insertion rubber washer 3mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 1729 75 mm diameter pipe
78Providing and fixing 100 mm sand cast ironS&S plain bend of required degree. Sand cast iron S&S as per IS - 1729 100 mm diameter pipe
79Providing and fixing 100 mm sand cast ironS&S plain bend of required degree. Sand cast iron S&S as per IS - 1729 75 mm diameter pipe
80Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Sand Cast Iron S&S as per IS: 1729. 100 mm
81Providing and fixing mirror of superior glass (ofapproved quality) and of required shape andsize with plastic moulded frame of approvedmake and shade with 6 mm thick hard boardbacking : Rectangular shape 453x357 mm
82Providing and fixing terminal guard 100 mmSand cast iron S&S as per IS - 1729
83Providing and fixing PTMT towel ring •trapezoidal shape 215 mm long, 200 mm widewith minimum distances of 37 mm from wallface with concealed fittings arrangement ofapproved quality and colour, weighing not lessthan 88 gms.
84Providing and fixing collar :Sand cast iron S&Sas per IS - 1729 100mm
85Providing and fixing collar :Sand cast iron S&Sas per IS - 1729 75 mm
86Excavating trenches of required width for pipes,cables, etc including excavation for sockets anddressing of sides, ramming of bottoms, depthupto 1.5 m including getting out the excavatedsoil and then returning the soil as required, inlayers not exceeding 20 cm in depth includingconsolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m : All kinds of soil Pipes, cables etc.exceeding 80 mm dia. but not exceeding 300mm dia
87Providing, laying and jointing glazed stonewarepipes class SP-1 with stiff mixture of cementmortar in the proportion of 1:1 (1 cement : 1fine sand) including testing of joints etc.complete : 150 mm diameter
88Providing and laying cement concrete 1:5:10 (1cement : 5 coarse sand : 10 graded stoneaggregate 40 mm nominal size) up to haunchesof S.W. pipes including bed concrete as perstandard design : 150 mm diameter S.W. pipe
89Providing and fixing square-mouth S.W. gullytrap class SP-1 complete with C.I. grating brickmasonry chamber with water tight C.I. coverwith frame o f 300 x300 mm size (inside) theweight of cover to be not less than 4.50 kg andframe to be not less than 2.70 kg as perstandard design:
90Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. linternal work - Exposed on wall 25 mm dia nominal bore
91Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. linternal work - Exposed on wall 50 mm dia nominal bore
92Providing and fixing G.I. pipes complete with al. fittings including trenching and refilling etc. External work 50 mm dia nominal bore
93Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long Screws etc. complete (New work) : 25 mm nominal bore
94Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
95Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
96Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
97Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore (Horizontal)
98Dismanteling of existing structures like culverts, bridges, retaining walls and otherstructure comprising of masonary, cement concrete, wood work, steel work, including T&P and scaffolding where necessary, sorting the dismanteled material with all lifts and lead of 1000m as per technical specification clause 202. By manual means. Reinforced cement concrete.
99Dismanteling stone masonry as per technical specification clause 202. Dismanteling of existing structures like culverts, bridges, retaining walls and otherstructure comprising of stone masonry , including disposal of unserviceable material and stackin the serviceable materialwith all lift and lead of 1000m as per technical specification clause 202. Rubble stone masonry in scement mortar.
100Earthwork in excavations for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil, Upto 3m depth.
101Earthwork in excavations for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil, Upto 3m depth. (Excavation done in Ground floor sheet) item 2.
102Providing Concrete for Plain preforced concreat in open foundation work PCC M10 (1:3:6) TS Clouse 802, 803, 1202 & 1203
103Random rubble stone masonry laid in 1:6 cement and sand mortar in breast walls, retaining walls, parapets, scuppers etc, including supply of all material, labour, T&P, and royalties etc. complete as per drawing andtechnical specifications. Clauses 702, 704, 1202 & 1203 of MORD specification.
104Hand packed stone filling in back of walls including cost of materials, royalty, T&P etc. complete as per direction of Engineer in charge. (As per PWD Uttarakhand specifications).
105Jaquar Bathroom Waterfall Showers Stainless Steel of thickness 0.9 mm and Grade Designation X04Cr19Ni9 of IS 5522/1992
106Supply LED Tube light 18W.
107Supply & fixing of Mirror Light -
108SUPPLY OF LED Glass Bulb B22, 12 W , Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56951598
AUTHORITY Government Departments
TENDER VALUE 5.40 Crore
LAST DATE 25-08-2026
Authority
Authority Name Uttarakhand Agriculture Produce Marketing Board
Work Description Tender for Construction Work Of Multi-Level Parking In Kanda (Bageshwar)
Basic Detail
Tender No e-nivida-803/2026
Bidding Type Tender
Location
City Bageshwar
State Uttarakhand
Key Dates
Publish Date 11 Aug 2026
Submission Date 25 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 5.40 Crore
Tender Fee 4720
EMD 10.82 Lakhs
Exemption Not Available
Document List
BOQ_116593.xls
dba372ca-6f87-4a83-90df-8979df84b2a2.html
SBDkanda.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_116593.xls

html

dba372ca-6f87-4a83-90df-8979df84b2a2.html

pdf

SBDkanda.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender