Defence Government Departments Closing in 18 days TDR #56951220

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Onboard In Ships And Submarines; Rate Contract For Services Of Helium Leak Checks For Underwater Systems Of In Ships And Submarines For A Period Of

Issued by Government Departments · Mumbai, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Sep 2026
18 days left
EMD
1.53 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Onboard In Ships And Submarines; Rate Contract For Services Of Helium Leak Checks For Underwater Systems Of In Ships And Submarines For A Period Of Two Years; Service Pr.. - Services For In Ships: Helium Leak Checks Of Underwater Devices Sniffing Mode : Fill The Device To Be Leak Tested With A He/Nitrogen Gas Mixture To About 2 Bar (Higher Is Better) And Then Cover It With Plastic For 8 Hours.Then One Pierces The Plastic With A Sniffer Probe Attached To The He Leak Detector, Allowing Us To Sniff Leaks Down To 10^-6 Torr L/Sec.Once Overall Leak Is Found, The Plastic Cover Is Removed And Sniff All Joints. This Is A Lengthy Procedure Because One Must Wait At Each Point To Gather Enough He Coming Out Which Is The Standard Procedure. , Services For In Ships: Helium Leak Checks Of Underwater Devices Spray Mode (Vacuum Mode) : This Technique Is Much More Sensitive, Reaching 1X10-9 Torr L/Sec.The Device To Be Leak Tested Is Pumped Down Using A Turbo/Rotary Pump Combination To Reach A Vacuum Better Than 10^-3 Torr (A Better Vacuum Yields Better Results)Once Base Vacuum Is Reached The System Is Connected The Helium Leak Detector. Now, Helium Is Sprayed Very Fine To All Joints Which Indicate Where Leak Is And How Much Is The Leak. , Services For In Submarine: Helium Leak Checks Of Underwater Devices Sniffing Mode : Fill The Device To Be Leak Tested With A He/Nitrogen Gas Mixture To About 2 Bar (Higher Is Better) And Then Cover It With Plastic For 8 Hours.Then One Pierces The Plastic With A Sniffer Probe Attached To The He Leak Detector, Allowing Us To Sniff Leaks Down To 10^-6 Torr L/Sec.Once Overall Leak Is Found, The Plastic Cover Is Removed And Sniff All Joints. This Is A Lengthy Procedure Because One Must Wait At Each Point To Gather Enough He Coming Out Which Is The Standard Procedure. , Services For In Submarine: Helium Leak Checks Of Underwater Devices Spray Mode (Vacuum Mode) : This Technique Is Much More Sensitive, Reaching 1X10-9 Torr L/Sec.The Device To Be Leak Tested Is Pumped Down Using A Turbo/Rotary Pump Combination To Reach A Vacuum Better Than 10^-3 Torr (A Better Vacuum Yields Better Results)Once Base Vacuum Is Reached The System Is Connected The Helium Leak Detector. Now, Helium Is Sprayed Very Fine To All Joints Which Indicate Where Leak Is And How Much Is The Leak.

BOQ

Sl. No. Item TitleItem Description
1Services for IN Ships: Helium leak checks of underwater devices Sniffing Mode : Fill the device to be leak tested with a He/Nitrogen gas mixture to about 2 bar (Higher is better) and then cover it with plastic for 8 hours.Then one pierces the plastic with a sniffer probe attached to the He leak detector, allowing us to sniff leaks down to 10^-6 torr L/sec.Once overall leak is found, the plastic cover is removed and sniff all joints. This is a lengthy procedure because one must wait at each point to gather enough He coming out which is the standard procedure.Services for IN Ships: Helium leak checks of underwater devices Sniffing Mode : Fill the device to be leak tested with a He/Nitrogen gas mixture to about 2 bar (Higher is better) and then cover it with plastic for 8 hours.Then one pierces the plastic with a sniffer probe attached to the He leak detector, allowing us to sniff leaks down to 10^-6 torr L/sec.Once overall leak is found, the plastic cover is removed and sniff all joints. This is a lengthy procedure because one must wait at each point to gather enough He coming out which is the standard procedure.
2Services for IN Ships: Helium leak checks of underwater devices Spray Mode (Vacuum Mode) : This technique is much more sensitive, reaching 1x10-9 torr L/sec.The device to be leak tested is pumped down using a Turbo/rotary pump combination to reach a vacuum better than 10^-3 torr (A better vacuum yields better results)Once base vacuum is reached the system is connected the Helium leak detector. Now, Helium is sprayed very fine to all joints which indicate where leak is and how much is the leak.Services for IN Ships: Helium leak checks of underwater devices Spray Mode (Vacuum Mode) : This technique is much more sensitive, reaching 1x10-9 torr L/sec.The device to be leak tested is pumped down using a Turbo/rotary pump combination to reach a vacuum better than 10^-3 torr (A better vacuum yields better results)Once base vacuum is reached the system is connected the Helium leak detector. Now, Helium is sprayed very fine to all joints which indicate where leak is and how much is the leak.
3Services for IN Submarine: Helium leak checks of underwater devices Sniffing Mode : Fill the device to be leak tested with a He/Nitrogen gas mixture to about 2 bar (Higher is better) and then cover it with plastic for 8 hours.Then one pierces the plastic with a sniffer probe attached to the He leak detector, allowing us to sniff leaks down to 10^-6 torr L/sec.Once overall leak is found, the plastic cover is removed and sniff all joints. This is a lengthy procedure because one must wait at each point to gather enough He coming out which is the standard procedure.Services for IN Submarine: Helium leak checks of underwater devices Sniffing Mode : Fill the device to be leak tested with a He/Nitrogen gas mixture to about 2 bar (Higher is better) and then cover it with plastic for 8 hours.Then one pierces the plastic with a sniffer probe attached to the He leak detector, allowing us to sniff leaks down to 10^-6 torr L/sec.Once overall leak is found, the plastic cover is removed and sniff all joints. This is a lengthy procedure because one must wait at each point to gather enough He coming out which is the standard procedure.
4Services for IN Submarine: Helium leak checks of underwater devices Spray Mode (Vacuum Mode) : This technique is much more sensitive, reaching 1x10-9 torr L/sec.The device to be leak tested is pumped down using a Turbo/rotary pump combination to reach a vacuum better than 10^-3 torr (A better vacuum yields better results)Once base vacuum is reached the system is connected the Helium leak detector. Now, Helium is sprayed very fine to all joints which indicate where leak is and how much is the leak.Services for IN Submarine: Helium leak checks of underwater devices Spray Mode (Vacuum Mode) : This technique is much more sensitive, reaching 1x10-9 torr L/sec.The device to be leak tested is pumped down using a Turbo/rotary pump combination to reach a vacuum better than 10^-3 torr (A better vacuum yields better results)Once base vacuum is reached the system is connected the Helium leak detector. Now, Helium is sprayed very fine to all joints which indicate where leak is and how much is the leak.

AI Tender Summary

OUR REF NO 56951220
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 01-09-2026
Authority
Authority Name Indian Navy
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Onboard In Ships And Submarines; Rate Contract For Services Of Helium Leak Checks For Underwater Systems Of In Ships And Submarines For A Period Of Two Years; Service Pr.. - Services For In Ships: Helium Leak Checks Of Underwater Devices Sniffing Mode : Fill The Device To Be Leak Tested With A He/Nitrogen Gas Mixture To About 2 Bar (Higher Is Better) And Then Cover It With Plastic For 8 Hours.Then One Pierces The Plastic With A Sniffer Probe Attached To The He Leak Detector, Allowing Us To Sniff Leaks Down To 10^-6 Torr L/Sec.Once Overall Leak Is Found, The Plastic Cover Is Removed And Sniff All Joints. This Is A Lengthy Procedure Because One Must Wait At Each Point To Gather Enough He Coming Out Which Is The Standard Procedure. , Services For In Ships: Helium Leak Checks Of Underwater Devices Spray Mode (Vacuum Mode) : This Technique Is Much More Sensitive, Reaching 1X10-9 Torr L/Sec.The Device To Be Leak Tested Is Pumped Down Using A Turbo/Rotary Pump Combination To Reach A Vacuum Better Than 10^-3 Torr (A Better Vacuum Yields Better Results)Once Base Vacuum Is Reached The System Is Connected The Helium Leak Detector. Now, Helium Is Sprayed Very Fine To All Joints Which Indicate Where Leak Is And How Much Is The Leak. , Services For In Submarine: Helium Leak Checks Of Underwater Devices Sniffing Mode : Fill The Device To Be Leak Tested With A He/Nitrogen Gas Mixture To About 2 Bar (Higher Is Better) And Then Cover It With Plastic For 8 Hours.Then One Pierces The Plastic With A Sniffer Probe Attached To The He Leak Detector, Allowing Us To Sniff Leaks Down To 10^-6 Torr L/Sec.Once Overall Leak Is Found, The Plastic Cover Is Removed And Sniff All Joints. This Is A Lengthy Procedure Because One Must Wait At Each Point To Gather Enough He Coming Out Which Is The Standard Procedure. , Services For In Submarine: Helium Leak Checks Of Underwater Devices Spray Mode (Vacuum Mode) : This Technique Is Much More Sensitive, Reaching 1X10-9 Torr L/Sec.The Device To Be Leak Tested Is Pumped Down Using A Turbo/Rotary Pump Combination To Reach A Vacuum Better Than 10^-3 Torr (A Better Vacuum Yields Better Results)Once Base Vacuum Is Reached The System Is Connected The Helium Leak Detector. Now, Helium Is Sprayed Very Fine To All Joints Which Indicate Where Leak Is And How Much Is The Leak.
Basic Detail
Tender No GEM/2026/B/7739256
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 11 Aug 2026
Submission Date 01 Sep 2026
Open Date 01 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.53 Lakhs
Exemption Not Available
Document List
dfe38aa3-1335-4c60-b2e5-b4bdb6c6bf5e.pdf
1785927285.pdf
1785927287.pdf
1786435774.xlsx
FINAL_e44d9e57-2135-447f-80da1786435818323_SMCOM.pdf
SafetyClau_8105634c-61c3-4461-8e301785925526436_COM_FM.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

dfe38aa3-1335-4c60-b2e5-b4bdb6c6bf5e.pdf

pdf

1785927285.pdf

pdf

1785927287.pdf

xlsx

1786435774.xlsx

pdf

FINAL_e44d9e57-2135-447f-80da1786435818323_SMCOM.pdf

pdf

SafetyClau_8105634c-61c3-4461-8e301785925526436_COM_FM.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders