Defence Statutory Bodies & Commissions/Committees Closing in 22 days TDR #56949353

Tender For Provn Of Single Officer Accn For Student Officers Of Army War College Under Ge (Awc) Mhow

Issued by Statutory Bodies & Commissions/Committees · Indore, Madhya Pradesh
Tender Value
91.71 Crore
Estimated cost
Bid Submission
15 Sep 2026
22 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Single Officer Accn For Student Officers Of Army War College Under Ge (Awc) Mhow

BOQ

Name of Work:- PROVN OF SINGLE OFFICER ACCN FOR STUDENT OFFICERS OF ARMY WAR COLLEGE UNDER GE (AWC) MHOW
Sl. No. Item Description
1SCHEDULE \\"A\\" Part-I (Building/Structures) (To be quoted by the tenderer)
2Item No 01 : Design and Construction of block of Single living accn for 40 Nos student officers with stilt parking (S+5) with permanent specification including RCC frame structure, fly ash brick masonry in super structure , pre- construction ATT, APP water proofing treatment, grit finish plaster on external wall, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
3Item No 02 : Design and Construction of block of Single living accn for 35 Nos student officers with stilt parking (S+5) with permanent specification including RCC frame structure, fly ash brick masonry in super structure , pre- construction ATT, APP water proofing treatment, grit finish plaster on external wall, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
4Item No 03 : Design and Construction of block of Servent Qtr for 70 Nos servent (G+4) with permanent specification including RCC frame structure, fly ash brick masonry in super structure, pre- construction ATT, APP APP water proofing treatment complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
5Item No 04 : Design and Construction of block of Servent Qtr for 66 Nos servent (G+4) with permanent specification including RCC frame structure, fly ash brick masonry in super structure, pre- construction ATT, APP APP water proofing treatment complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
6Item No 05 : Design and Construction of pump house building with permanent specification including RCC frame structure, pre-construction ATT, APP water proofing treatment, fly ash brick masonry IN super structure , etc complete. Under Gp VII (iii) for Pump House complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
7Item No 06 : Design and Construction of Sub Station bldg with permanent specification including RCC frame structure, pre-construction ATT, APP water proofing treatment on roof , burnt cly brick masonry in super structure , etc complete. complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
8Item No 07 : Design and Construction of UG sump 40000 gallon capacity with permanent specification RCC structure in wall,foundation and dome , necessary water proofing treatment to bottom and wall of sump including all earthwork,PCC bed for foundation,cement base paint to wall externally complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents.
9Sch 'A' Part-II (External Electric supply) Lump sum price worked out by the contractor for (External Electric supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
10Sch 'A' Part-III (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES.
11Sch 'A' Part-IV (Road Path Culvert) Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
12Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES.
13Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
14Sch 'A' Part-VII (Compound Wall) Lump sum price worked out by the contractor for (Compound Wall) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES.
15Sch 'A' Part-VIII (Rain Water Harvesting) Lump sum price worked out by the contractor for (Rain Water Harvesting) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES.
16Sch 'A' Part-IX (Sewage treatment Plant) Lump sum price worked out by the contractor for (Sewage treatment Plant) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES.
17Sch 'A' Part-X (Concealed LAN conduiting) Lump sum price worked out by the contractor for (Concealed LAN conduiting) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
18Sch 'A' Part-XI (Split AC) Lump sum price worked out by the contractor for (Split AC) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES.
19Sch 'A' Part-XII (Lift) Lump sum price worked out by the contractor for (Lift) as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES.
20Sch 'A' Part-XIII (Lighting Protection) Lump sum price worked out by the contractor for (Lighting Protection) as listed in Schedule 'A' Part-XIII against the lump sum price inserted by the MES.
21Sch 'A' Part-XIV (Geyser) Lump sum price worked out by the contractor for (Geyser) as listed in Schedule 'A' Part-XIV against the lump sum price inserted by the MES.
22Sch 'A' Part-XV (Water Cooler) Lump sum price worked out by the contractor for (TV connection & conduit for Telephone connection) as listed in Schedule 'A' Part-XV against the lump sum price inserted by the MES.
23Sch 'A' Part-XVI (Fire Fighting) Lump sum price worked out by the contractor for (Fire Fighting) as listed in Schedule 'A' Part-XVI against the lump sum price inserted by the MES.
24Sch 'A' Part-XVII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-XVII against the lump sum price inserted by the MES.
25Sch 'A' Part-XVIIA (Internal Electrification) Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule 'A' Part-XVIIA against the lump sum price inserted by the MES.
26Note for Srl No 9 to 25The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 9 to 25 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule
27Schedule 'A' Part-XVIII (Miscellaneous items of works)
28Sewage Disposal
29Item No 08 : S&F in 150 mm dia HDPE DWC pipe laid in trenches, Class SN 8 structured wall polyethylene piping system (pipe with online/offline coupler and elastomeric sealing ring) with non-smooth external annular corrugated and smooth internal surfaces (double wall) for non-pressure underground sewerage application conforming to IS 16098 (Part-2):2013, complete all as specified and directed.Note:-1. Colour: Outer Black / Inner Orange.2. The pipes shall conform to IS 16098 (Part-2): 2013 and shall be marked with BIS. The work shall be carried out to living conditions.
30Rain Water Harvesting
31Item No 09 : M&L for loose filling with broken stone or boulder aggregate of gauge 20 as in filter bed complete all as specied.
32Compound Wall
33Item No 10 : Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star rated ( For each single offrs Accn)
34Item No 11 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 0.5 KVA complete all as specified.
35Split AC
36Item No 12 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified.
37Item No 13 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified.
38Item No 14 : M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 20x3 mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
39Item No 15 : RCBO DP, 32 Amp, 240/415 volts, conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected 35 mm² terminals, colour coded on/off indication on dolly, integrated label holder, etc complete all as specified and directed.
40Item No 16 : RCBO DP, 40 Amp, 240/415 volts, conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected 35 mm² terminals, colour coded on/off indication on dolly, integrated label holder, etc complete all as specified and directed.
41Lifting Protection
42Item No 17 : M & L for earthing of lightning protection to Bldg with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised iron earth strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
43Water Cooler
44Item No 18 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified.
45Fire Fighting
46Item No 19 : Supply and fix fire hydrant stand post with provn of single outlet conforming to IS 908
47Item No 20 : Supply, installation, testing and commissioning of hose cabinet of internal type to accommodate pipes alongwith one pair of male and female coupling and one branch pipe. The cabinet is made of MS sheet, glass fronted with hinged door and lock of min size 1.5 M x 1.0 M x .5 M . The cabinet is spray painted to scarlet red color outside.
48Item No 21 : Supply and fix Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete
49Item No 22 : Supply and laying UG cable 2Core 1.5 Sq.mm copper cable ISI marked with proper clamping, supports and terminations..
50Item No 23 : Supply and fix Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete
51Item No 24 : Deign, Fabricate, Supply, Installing, Testing and Commissioning of Electrically control panel of cubical construction, Wall mounting type, free standing , compartmentalised , sectionailsed , dust , damp and vermin proof with suitable ventillation fabricated out of 2.0 mm thick CRCA sheet and angle iron , spray painted with approved colour shade , suitable for 415V , 50 Hz 3 phase , 4 wire systtem complete in all respect and confirming to latest revised ISI specifications including necessary connections , inter connections with copper conductor cable of required size ( from starter ground floor to starter panel on terrous ) , cable end termination , necessary cable tray of requierd size , soldering etc with and including following switch gears mounted thereon as required ( All switch fuse /fuse switch units shall be to AC 230 V duty IS: 4064) compete all as specified and directed.
52(a) 32 Amps 4P MCB 'C' series as incomming (b) Digital volt meter.-01 Nos(c) Digital Ampere meter.-01 Nos(d) Automatic star Delta starter for centrifuga; pump set 12.5 HP , opetaion based on presuure drop on fire lines the required pressure in main line. If the main pump set fails to start with in 10 seconds, run procedure/ program for automatic start operation of required constant pressure from varring low pressure in main line with in 10 seconds complette all as specified and directed.
53Item No 25 : Supply installation , testing and commissioning of Electric motor driven fire pumping set consisting of and including the following complette all as specified and directed.
54(a) Centrifugal horizondal suction type multi stage pump complete for delivery 900 Ltr/minute against a total head of 35 Mtrs with and including cast iron casing, bronze impelller and stainless steel shaft directely coupled through flexible coupling with electric motor as required.
55(b) Squirrel cage AC induction motor suitable for operation 415V(+/- 10%) three phase , 50 Hz AC supply of not less rhan 12.5 HP with synchronomous speed of 2900 RPM ( with permissible slip) . The motor shall have 'B' class insulation and the enclosure shall be TEFC type confirming to protection class IP 55 of IS: 4691. The motor shall be rated for continuous duty.
56(c) Common base plate fabricated out of MS Channel of size 75x150 mm
57(d) Suitable RCC pump foundation as per manufactors design with vibration damping arrangement by providing cushy foot or similar mounting as required.
58(e) Pressure switches for ire pumps complete with mini ball valve
59(f) Pressure gauge complete with mini ball valve and siphon tube.
60Item No 26 : M&L for Dry chemical powder (ABC) type 6 kg fire extinguishers all as specified and directed.
61Item No 27 : M&L CO2 type fire extinguishers 4.5 kg all as specified and directed.
62Item No 28 : M&L CO2 gas( stored pressure) type 9 kg fire extinguishers all as specified and directed.
63Item No 29 : M&L Mechanical Foam( stored pressure) 9 Ltr type fire extinguishers , media AFF foam all as specified and directed.
64Item No 30 : S & F LED Light RED in color show in 'EXIT' sign in one direction along with minimum battery backup with of 2 Hrs. Complete all as specified and directed.
65Item No 31 : Supply, installation, testing and commissioning of networkable active repeater panel with 40 character LCD display connected peer to peer with \\"Main Fire Alarm Panel\\" with accept, reset functions complete all as specified and directed.
66Item No 32 : S & F fire bucket of capacity 09 Itrs conforming to IS 2546 with accessories complete all all as as specified specified and and directed.
67Item No 33 : S & F bucket stand for made of MS angle 50x50x6 mm of size 6ftx5ftx3ft with bucket hanging arrangement of four nos, alongwith fabrication of canopy of 18 swg of MS Sheet Note: The basev will be 0.6 mtr wide incl painting of one coat red oxide primer paint and two coat of P.O red enamel ISI marked paint.
68External Water Supply
69Item No 34 : supply and Install pumping set, centrifugal, electric driven, 3 phase, 440 volts, 50 hz 25 HP complete including foundation all as specified and directed.
70Item No 35 : Supply and fix starter 25 HP three phase 13-21A, fully automatic star delta complete all as specified and directed.
71Item No 36 : Supply and lay pipe ductile Iron , S/S including specials, Class “K-9” ,150 mm (6”) dia
72Item No 37 : Supply and lay pipe ductile Iron , S/S including specials, Class “K-9” ,100 mm (4”) dia
73Item No 38 : Supply and fix Valves, Sluice, flanged of class 1.6 PN ,150 mm (6”) dia.
74Item No 39 : Supply and fix Foot Valve conforming to IS 4038, 100mm (4”) dia.
75Item No 40 : Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia.
76Item No 41 : Supply and fix Valves, Sluice, flanged of class 1.6 PN ,100 mm (4”) dia.
77Item No 42 : Supply and fix Valves, Sluice, flanged of class 1.6 PN ,80 mm (4”) dia.
78Item No 43 : Supply and fix direct cylinder mounted type vacuum chlorinator for pressure feed including all gauges, pump, motor conforming to IS 10553 part - 2 having capacity 1.0 to 1000gm/hr.
79Item No 44 : Supply,installation, commissioning and testing, LT indoor type Lt panel board assembled fabricated (CPRI APPROVED) and of suitable size angle iron, channel and MS sheet 2 mm thick (Inner compartment is 2.0 mm thick), double door type, front and rear openable with locking arrangement, duly powder coated painted with locking arrangement and independently housing for each control switch gear duly prewired with colour coading for three phases and neutral, Busbar 400 amps for 415 volts, 50 Hz electric supply with and including suitable sizes of cable glands for incoming and outgoing cables, grouting the panel board on and including suitable size foundation structure made out if equale angle iron as mentioned mentioned below installation, comissioning and testing complete with the following switch gears/ accessories :- ( pump house)
80Incoming :-
81(a) MCCB 160 Amps , 50 KA, 415 Volts - 01 No
82(b) Digital Ammeters 0-400 Amps suitable ratio CT rating and selector switch- 01 No
83(c) Digital Voltmeter with selector switch 0-500 volts,- 01 No
84(d) Indicating LED lamps (RYB)-01 Set
85Outgoing :-
86(a) MCCB TPN 100Amps, 25KA ,415 Volts - 04 nos
87(b) MCB TPN 63 Amps , 415 Volts - 02 nos
88(c) MCB SPN 40 Amps, 25 KA, 230 Volts - 3nos
89(d) Star Delta stater with fault protection relay and OLP of 15 HP, 415 volts , 15 Hz
90Item No 45 : M & L for Construction of fly-ash brick masonary valve chamber of size 900 mm X 900 mm X 900 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
91Item No 46 : M & L for Construction of fly-ash brick masonary valve chamber of size 1000 mm X 800 mm X 1000 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
92Item No 47 : M & L for Construction of fly-ash brick masonary valve chamber of size 1200 mm X 1200 mm X 1200 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
93DG SET
94Item No 48 : Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears with automatic starting on main failure, (AMF) control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity upto 100KVA ( For Pump House and Street light )
95Item No 49 : Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears with automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity upto 500 KVA.
96Item No 50 : Supply & fix Bulk Meter (Trivector meter ) three phase four wire ,with neutral, ,CT- operated, Rated voltage 230 V AC, -20% to + 15%, maximum voltagee 300V (L-N) Continuos, class 0.5 -2.0 accuracy, frequency 50Hz, metrology LED lamp with two configurable for active and reactive energy. Make SECURE
97SEWAGE TREATMENT PLANT
98Item No 51 : Designing (hydraulically, structurally & aesthetically), providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of 100 KLD capacity STP consisting of Inlet chamber(RCC), Fine bar Screen chamber(manual) RCC with steel screen, Oil & Grease Remover(RCC), Grit separator, Equalization Tank( 2 Tanks of 50% Capacity each), Air Grid for Equalization Tanks, Feed Pumps(2 No), Moving Bed Bio Reactor(s) with plastic media (of appropriate density, size and quantity to keep very high MLSS > 15,000 mg/lit), Air Blowers for MBBR, Tube Settler assembly, Sludge Drying Bed of appropriate size, Chlorine Dozing System, Chlorine contact tank, Foundation for all E/M equipments,
99Associated piping work with required valves, gates, drains, pathways, Electrical control Panel with interconnecting cable, spare parts for 2 years of operation, etc. complete as turnkey job with all involved civil, electrical, digital and mechanical works as per detailed specifications for civil, electrical and mechanical components with all duties and taxes complete. (Also refer imp notes below).For tertiary treatment it also includes Filter Feed Tank of RCC, Filter Feed Pumps, Dual Media Filter, Activated Carbon Filter, Treated water Tank in RCC. Treated sewage can be used for irrigation, horticulture, fire fighting and MT wash.
100External Electric Supply
101Item No 52 : Supply installation APFC Panel with MD-LX capacitor and MCCB of capacity 450KVAR with 8 steps (2x100+4x50+2x25)
102Item No 53 : Supply, installation, commissioning and testing, LT indoor type Lt panel board assembled fabricated (CPRI APPROVED) and of suitable size angle iron, channel and MS sheet 2 mm thick (Inner compartment is 2.0 mm thick), double door type, front and rear openable with locking arrangement, duly powder coated painted with locking arrangement and independently housing.Incoming :-(a) ACB 1250 Amps, 50 KA, 415 Volts - 01 No(b) Digital Ammeters 0-2000Amps suitable ratio CTrating and selector switch- 01 No(c) Digital Voltmeter with selector switch 0-500 volts (e)Digital type Voltmeter 0-500 V,- 01 No(d) Indicating LED lamps (RYB)-01 Set
103Outgoing :-(a) MCCB 160 Amps, 36KA,415 Volts - 05nos(a) MCCB 500 Amps, 36KA,415 Volts - 01nos(a) MCCB 630 Amps, 50KA,415 Volts - 01nos(a) MCCB 250 Amps, 36KA,415 Volts - 02nos
104Item No 54 : Supply, installation, commissioning and testing, LT outdoor type Lt panel board assembled fabricated (CPRI APPROVED) and of suitable size angle iron, channel and MS sheet 3mm thick (Inner compartmentIncoming:-(a) ACB 800 Amps, 50KA, 415 Volts - 01 No(b) Digital Ammeters 0-1000 Amps suitable ratio CTrating and selector switch- 01 No(c) Digital Voltmeter with selector switch 0-500 volts(d) Indicating LED lamps (RYB)-01 SetOutgoing :-(a) MCCB TPN160 Amps, 36 KA,415 Volts - 04nos)(c) MCB SPN 40 Amps, 415 Volts-2nos
105Item No 55 : Supply, installation, commissioning and testing, LT out door type LT panel board assembled fabricated (CPRI APPROVED) and of suitable size angle iron, channel and MS sheet 3 mm thick (Inner compartment is 2.0Incoming :-(a) MCCB 4 pole 630 Amps, 50KA, 415 Volts-01 Nos(b) Digital Ammeters 0-1000 Amps suitable ratio CTrating and selector switch- 01 No
106(c) Digital Voltmeter with selector switch 0-500 volts (e) Digital type Voltmeter 0-500 V,- 01 No(d) Indicating LED lamps (RYB)-01 SetOutgoing :-(a) MCCB TPN 160 Amps, 50KA,415 Volts - 03 Nos(b) MCB TPN 32 Amps, 415 Volts -01 Nos
107Item No 56 : Supply, installation, commissioning and testing, LT out door type LT panel board assembled fabricated (CPRI APPROVED) and of suitable size angle iron, channel and MS sheet 3 mm thick (Inner compartment is 2.0Incoming-(a) MCCB 500 Amps, 36KA, 415 Volts - 01 No(b) Digital Ammeters 0-500 Amps suitable ratio CTrating and selector switch- 01 No(c) Digital Voltmeter with selector switch 0-500 volts(e) Digital type Voltmeter 0-500 V,- 01 No(d) Indicating LED lamps (RYB)-01 SetOutgoing :-(a) MCCB TPN 160 Amps, 36KA,415 Volts-05 Nos(b) MCB TPN 32 Amps, 415 Volts -02 Nos
108Item No 57 : Supply, installation, commissioning and testing, LT out door type LT panel board assembled fabricated (CPRI APPROVED) and of suitable size angle iron, channel and MS sheet 3 mm thick (Inner compartment is 2.0Incoming-(a) MCCB 350 Amps, 36KA, 415 Volts - 01 No(b) Digital Ammeters 0-500 Amps suitable ratio CTrating and selector switch- 01 No
109(c) Digital Voltmeter with selector switch 0-500 volts(e) Digital type Voltmeter 0-500 V,- 01 No(d) Indicating LED lamps (RYB)-01 SetOutgoing:-(a) MCCB TPN 32 Amps, 25KA,415 Volts - 08 Nos(c) MCB SPN 40 Amps, 230 Volts -02 Nos
110Item No 58 : Supply & fix Microprocessor based Single phase electronic temper proof energy meter of rating 10 to 60Amp with optical communication port, conforming to IS: 13779.
111Item No 59 : Supply & fix Bulk Meter (Trivector meter) three phase four wire, with neutral,,CT- operated, Rated voltage 230 V AC, -20% to +15%, maximum voltagee 300V (L- N) Continuos, class 0.5 -2.0 accuracy, frequency 50Hz, metrology LED lamp with two configurable for active and reactive energy.
112Internal Electrification
113Item No 60 : S& F of LED bulb E27 Cool Day light 9 watts 3 star Lamp having Luminous Efficacy range lies between ( ≥90 and <105 ) lm/W as per BEE guidelines Long Life 15000 hours In-built surge protection of 3 kV Warranty of 1 Year complete all as specified and as directed.
114Item No 61 : S & F modular type TV Socket out let complete all as specified and as directed.
115Item No 62 : S & F modular type LAN Socket RJ 45 with complete box
116Item No 63 : S & F modular type Telephone socket RJ 11/12 with complete box
117Item No 64 : S & F for wall mount Panel of thickness 2.0mm of with 1000 Amps copper rated bus bar 415 volts suitable for incomming MCCB 125 Amp,4 pole, 36KA -01 Nos Modules and outgoing MCCBs 4 pole 63 Amps,16 KA - 06 Nos ,TPN MCBs 4 pole 40 Amps, 16KA -02 Nos Modules, MCCB should be fixed thermal magnetic type with spreader link and phase seperator, necessary copper cabling , Phase indication lamp LED type , Digital ammeter, voltmeter Each module shoul be minimum size 450mmX450mm with necessary fixing arraangement including necessary provision forfixing on wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.(Main Panel)
118Item No 65 : S & F for sheet metal enclosure MCCB DB VTPN 4 way Vertical type with min 200 Amps rated bus bar 415 volts for incomming MCCB 4 pole -01 Nos and out going 12 Nos MCB Modules with double door with magnitic locking system including including blanking plate necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.(Ground floor)
119Item No 66 : S & F modular MCB protected socket comprising of 32A MCB C curve, and 16/20 A Socket for AC/Geyser, modular switch 16A complete with Sheet metal Enclosure for 230 volt 50 Hz AC including all acessories as one complete set all as specified and as directed .
120Item No 67 : M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of GI wire up to 7.5 mtr connected to earthing point complete all as specified and as directed.
121Design, supply, installation, testing, commissioning & integration of Advance Metering Infrastructure (AMI) comprising of performing site survey, setting up the communication network in such a way that service level agreement related to data availability/connectivity of the consumers are achieved. It shall include smart meters of different makes ( not more than 33% of a particular make to ensure interchangeability at a later date as per BIS 16444). It will include the following components:-
122Item No 68 : Supply, installation, testing and commissioning single phase smart electric meter having applicable standard complying with BIS marked IS-16444 : 2015 (Reaffirmed 2020) for all requirement reference voltage 240 Volts, current rating 10-60 Amps, UC1, category, complying of IS 16444 Part-I to starting current, accuracy class 1.0, limits of error, frequency, influence quantities, power consumption of meter, current and voltage circuit running at no load, test output device, meter display , name plate and making meter display, LED/LCD indicators, measuring element, Alarm, Load control, status of load switch, programmability, communication, date exchange protocol, real time clock (RTC), data retention, first breath (power on) and last gap (power off) condition detection and communication to HES, data display facility. Complying to IS 13779 for operating temperature range, humidity complying to IS-15959 part-II for parameters to be measured, max demand resetting, time of use registers, power quality information, load survey/ internal data, tamper / event recording, Alarm, remote firmware, RTC (Part-II also IS15959).
123Anti tamper feature as per IS-1959 Part-II. The meter shall be supplied with edequate battery backup for RTC, must have a dedicated sealable slot for accomodation plug-in type bi-directional communication modules which shall integrate the respective communication tech with smart meter, leading to easy adaptability for network interfaces (WAN/NAN). including transparent polycarbonate Meter box complying to IS-14772 suitable for single phase smart Meter having sealable optical port provision on the cover of the meter box conform to IP-54 protection with push fit and hinge type including fixing arrangement such as nut, bolt, washer etc.
124Meter should support communication protocol through (RF/GPRS/Hybrid(GPRS+RF) ) with the software all as required at site and directed. In case of Cellular based meter, the meter shall accommodate SIM card of any service provider. Contractor have to bear the monthly rentals/ data charges for SIM/e-SIM using the network of Mobile service provider , mapping, vending portal charges etc for every meter for 2 Years in case. in case of RF meters cost of DCU, Signal boosters including network management and head end system for the project area shall also be included in this item and in case of Hybrid system all hardware/software component also. The plug-in module shall be field swappable / replaceable.
125The meter shall continue working under tamper condition and would log teh event and send alarm at HES (Head End System) after dedection of the defined tamper features. The minimum data display should include minimum of the following:-1. Data display shall be in two mades:- (a) Auto Scroll (b) Scroll with push button2. The display parameter shall be :- (a) Auto scroll (b) Display check (c) Date and time (d) Last recharge amount (e) Last recharge time (f) Current Balance amount (g) Current balance days left (h) cummulative active energy KWH with legend (j) Current calender month MD in KW with legend (k) Instantaneues Voltage (l) Instantaneues phase current (m) Instantaneues load KW (n) Instantaneues average power factor.These parameter should be displayed on the meter display contineously for a period of 10 seconds on auto scroll.
1263. Scroll with push button : All parameters mentioned under auto scroll mode should be displayed additionally, the following parameters shall also be displayed:- (a) Internal diagnostic (display check) (b) meter serial number (c) last month commulative KWH with legends (d) Last month MD in KW with legends (e) currenct month average power factor (f) Last month average power factor.
127Further, the meter shall display high resolution energu values with resolution of 3 digit before decimal and 2 digit after decimal in push button mode. The meter display should return to default display mode (contineous auto scroll) if push button is not operated for more than 10 seconds. Meter display should go in sleep mode during power on condition in case the push button is not operated for more than 10 seconds
128Notes for item 68 (a) It would be possible to run the meter in both prepaid and postpaid mode.(b) The meters would carry 10 years warranty.(c) The meter should be suitable/run/operate with all approved software.Note : Any technical item missed out which is technically required for Design, supply, installation, testing, commissioning & integration of Advance Metering Infrastructure (AMI) as per E-in-C Branch policy No 12/2023 issued by E-in- C's Branch letter No A/37696/Gen/Pol/E2W(PPC) dt 30 Aug 2023 (uploaded on MES website) during the execution of work without any extra cost.
129Item No 69 : Supply and Configuration of the Web based Software to integrate /configuration of smart meter with following modules and hosting the system to GCC for management of supplied software application: (i) Meter Data Management Module :-The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data:For Smart meter - 1843 Nos(a) Real time energy monitoring with 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency.(b) Monthly billing survey data for Cumulative energy and max demand Please Enable Macros to View BoQ information Schedule 'A' Part II (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
130Item No 69 : Supply and Configuration of the Web based Software to integrate /configuration of smart meter with following modules and hosting the system to GCC for management of supplied software application: (i) Meter Data Management Module :-The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data:For Smart meter - 1843 Nos(a) Real time energy monitoring with 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency.(b) Monthly billing survey data for Cumulative energy and max demand Please Enable Macros to View BoQ information Schedule 'A' Part II (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
131Supply and installation of copper wound transformer step up/ step down, level 3, indoor/outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity capacity 400 and upto 750KVAcomplete.(Cap of TR,1x 750 KVA )
132Supply and installation of copper wound transformer step up/ step down, indoor/outdoor type complete withstandard fittings, level-3, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity capacity 400 and upto 600KVA complete.(Cap of TR, 1x 500 KVA)
133Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)withstranded aluminium conductor, 11000 volts grade, of size 3 core 95sq mm complete all as specified & directed
134Supply and fix cable jointing kit for 11 KV grade cable for in door termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm
135Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, cold shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 95 sqmm
136Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp
137Supply installation APFC Panel with MD-LX capacitor and MCCB of capacity 300KVAR with 6 steps(1x100+3x50+2x25)
138Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630sq mm3.5 core
139Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 500sq mm3.5 core
140Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size240sq mm3.5 core
141Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185sq mm3.5 core
142Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size150sq mm3.5 core
143Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 120sq mm3.5 core
144Supply, laying and testing cable XLPE Insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 95sq mm3.5 core
145Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 70 sq mm3.5 core
146Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 50 sq mm3.5 core.
147Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
148Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 25 sq mm 4 core
14925 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
150Supply & installation of Galvanized steel high mast lighting system of 20 meter in two section, 3 mm section thickness, top dia 150 mm, bottom dia 340 mm, with 2/3 wire rope system and its accessories. System is suitable for loading 08 nos 80 to 150w LED lights
151Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate andfinial including foundation and coping
152Supply and fixing LED light fitting for street/security lighting energy saving & environmental friendly long life versatilepressure die-cast housing with toughened glass and individual high power LED with secondary optics of capacity 70/75 Watt 240 volts AC 50 Hz, IP 66 protection complete all as specified and directed.
153Excavation in trenches, n. exc. 1.5 m wide and n.exc 1.5 m in depth ;for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc.n. exc. 10 sq m on plan and n. exc. 1.5 m in depth and getting out soft/loose soil all as specified and as directed.
154M&L fine sand cushioning for cable protection in layers incl punning all as specified and directed.Note: Punned down thickness shall only be measured.
155Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and as directed.
156Returning, filling in, trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cm Soft / loose soil all as specified andas directed.
157Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5m above the starting point all as specified and asdirected.
158Supplying and laying un-reinforced precast concrete cable cover, Class HV, Type I, flat, size 300 mm x 180mm x 40mm all as specified and as directed.
159M&L Cement concrete in foundations filling and mass concrete using PCC type C2 1:3:6 40 mm graded stone aggregate as in foundation or mass concreted forfixing of poles or similar works complete all as specified and directed.
160M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified.
161Excavaion post holes (or similar holes) each n exc 0.5 cum, getting out sof /loose soil, returning filling in and ramming earth or broken rubble mixrd with eartth around in layers not exc 25 cm, watering and removing surplus soil to a disance not exc 50 m and making good surface complee all as specified and as direced.
162M & L high strength deformed TMT bars 10mm dia and over cutting length bent shape required including cranking bending spirally for hooping for columnshooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia complete all asspecified and direced
163S&F of mild steel angles bars flats etc as in supports for posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riverting etc and similiar work conforming to fe 410-0 or fe 165-0
164S& F galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2 mm dia barbs a 75 mm spacing and straining and fixing to any type sranded rails straining bolts including securing or tying at crossings with and provn of galvanised MS wire saplesor dseel pins ec all as specified(each line/row to be measure)
165Supply of chain link fencing including line wire an mesh and an type of sranded rails sraining bolts etc including provision of binding wire etc complete
166Fixing only chain link fencing including line wires and mesh size type of stadrads rail sraining bols etc size of mesh 100x100mm mm dia wire complee all asspecified and direced
167M & L for preparation of new or previously untreated steel surfaces of any description exc 10 cm width or girth not otherwise described and appling two coa of synthetic enamel paint over a coat of red oxide primer
168M&L for time light distribution board switches of capacity 65 amps digitial timer box including- (i) contactor rating 65 amp 3pole/230V, (ii) Digital timer programmable type and (iii) MCB 65 Amp
169Supply and fixing copper conductor flexible cable with PVC insulator multi-stranded 3 core 1.5sqmm.
170Supply and fix PVC Sintex box having aluminium bus bar suitable for street light connections including single pole MCB of rating 6 Amps, 2.5 sqmm copper comductor for connection and fixing arrangement to pole all as specified and directed by Engineer-in charge
171S&F street light Gl pipe bracket 40mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc
172M&L for galvanized steel tubing 40 mm dia light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed
173M&L for galvanized steel tubing 15 mm dia light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed Total carried over to BOQ Rs. 24000978.59 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part III (External Water supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
174Supplying, fixing, jointing and testing non-return valve suitable for GI tubing of size 150mm bore of following bore size, (ISI Marked) both ends flanged and drilled for jointing including two flange joints and jointing material such as nuts, bolts washers rubber packing etc including taking down complete all as specified and as directed.
175Supplying, fixing, jointing and testing non-return valve suitable for GI tubing of size 100mm bore of following bore size, (ISI Marked) both ends flanged and drilled for jointing including two flange joints and jointing material such as nuts, bolts washers rubber packing etc including taking down complete all as specified and as directed.
176Supplying, fixing, jointing and testing non-return valve suitable for GI tubing of size 80mm bore of following bore size, (ISI Marked) both ends flanged and drilled for jointing including two flange joints and jointing material such as nuts, bolts washers rubber packing etc including taking down complete all as specified and as directed.
177Supply and lay pipe galvanized, “Medium classs”, including fittings, 80 mm (3”) dia.
178Supply and lay pipe galvanized, “Medium classs”, including fittings, 40mm dia.
179Supply and lay pipe galvanized, “Medium class”, including fittings, 25 mm (1/2”) dia.
180Supply and fix Valve, stop, screwed,25 mm (1/2”) dia pipe
181Excavation in trenches, n. exc. 1.5 m wide and n.exc 1.5 m in depth ;for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc.n. exc. 10 sq m on plan and n. exc. 1.5 m in depth and getting out soft/loose soil all as specified and as directed.
182Returning, filling in, trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cm Soft / loose soil all as specified and as directed.
183Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5m above the starting point all as specified and as directed. Total carried over to BOQ Rs. 968579.75 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IV (Road Path Culvert) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
184Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-inchargeavation over area n.exceeding 1.5 M deep and getting out in soft /loose soil
185M&L for filling in road formation with moorum in layers n.exc 15cm thick spread, levelled and rammed including watering
186Rolling and consolidation of formation surface in cutting with power roller exc 8 tonne & n exc 12 tonne roller
187M & L for laying & Compacting 150mm thick ( compacted thickness) GSB grade I as specified table 400 1 of morth specification of Road and bridge works 2013 in a single layer over compacted subgrade with natural sand , crushed gravel , crushed stone , crushed slag or combination there of as per the gradimg required the material are mechanically mixed spread and levelling on subgrade by using mortar grader of adequate capacity 80 -100 Kn static weight for achieveing required compaction density of atleast 98 % of MDD consolidation required gradient and camber complete all as specified and directed with finished surface tolerance as per table 900 1 of MORTH specification of Road 2013, complete all as specified and directed.
188M&L for 100 mm thick dry lean cocrete (DLC) of aggregate gradation as per table 1 of SP 49:2014 having 7 days compressive strength not less than 7 MPa . minimum cement content not less than 140 kg/cum complete as directed by engineer in charge
189M&L for 200mm thick cement concrete work in pavement/hardstanding of flexture strength 40 Kg per Sqcm in field using 400 kg of cement per cubic metre, thickness of concrete 25cm or less including necessary formwork complete as directed by engineer in charge
190M & L for finishing surface of concrete roads pavements by belting
191M & L for forming 20 mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' for 200mm thick concrete slab
192M & L for forming Dummy joints 65mm deep X 10mm wide, filled with sealing compound Grade A
193M & L for forming construction joints 30mm deep X 10mm wide, filled with sealing compound Grade A
194Supply and laying 400 micron thick HDPE sheet (vergin quality) water proof , wrinkle free without punchure having minimum weight 390 gm/Sqm over sand cushion with overlap between adjacent strips and at tranverse joint as minimum 300 mm
195M & L for Providing 10mm thick sand coushion with clean river sand duly clear of residual, organic and deleterious materials spread evenly to uniform thickness laid over DLC layer. The sand cushion must not contain stones/other hard or uneven matter as specified and directed.
196M & L for 25mm dia mild steel TMT bars as in dowel bar including suitable metal cap at both ends partly filled with cotton complete all as specified and directed. Total carried over to BOQ Rs. 27844116.81 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part V (Sewage Disposal) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
197Earth work in excavation in trench by mechanical means (Hydraulic excavator) in aa type of soil (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge
198M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate ) in foundation.
199M&L for PCC solid block masonry with C (5.0) grade solid units having density not less than 1800kgs/Sqm as per Is 2185 Pt-1 built in CM 1:6, exc. 10 cm in width and setting in mortar, complete all as specified and as directed.
200M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished smooth and even without using extra cement.
201M&L for PCC 1:3:6 type C-2 (using 20mm graded stone aggregate ) in concrete bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore.
202M& L for SRFC factory made manhole cover square/rectangular/ circlar shape for using cover to maholes complete as directed.
203Supply only Compound water proofing compound
204Returning filling in including spreading levelling, watering and well ramming in layers n.exc 25cm thick in hard /dence soils.
205Removal of excavated soil exec 1.5 KM and n exc 5.00 KM and deposition (out side MD Land) at a level n exc 1.5m above the starting point
206M&L Plain Cement Concrete Type B0 1:2:4 (using 12.50 mm graded granite stone aggregate) as in benching of man holes including forming centre channels half round or 1/4 section complete all as specified. Total carried over to BOQ Rs. 1722680.29 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VI (Area Drainage) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
207Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth : for foundation and getting out in ant type of soil
208PCC (1:4:8) Type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
209M&L for bricks work fly ash modular size bricks of compressive strength not less than 75 kg/sqcm strainght or curved on plan exc 6m mean radius joints built in cerment mortar 1:4 complete all as specified and directed..
210M&L for Rendering 15m thick in cm 1:4 on fiar faces of brick work or concrete furface of wall and finished even and smooth without using exstra cement complete all as specified and directed..
211M&L for Extra for forming fiar finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds,mitred/stopped ends etc complete all as specified and directed.
212M&L for Precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in landings cover slab (for manholesw etc) and similar work inculding necessary form work and set in CM 1:6 complete all as specified and directed.
213M&L Mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securin with clips complete all as specified and directed.
214M&L Plain Cement Concrete 1:2:4 Type B1 (using 20 mm graded granite stone aggregate) as in coping including necessary form work and all as directed.
215S&F for 300 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified
216M&L for 300 mm dia Concrete bed to drain pipes CC 1:4:8 type D-2 including packing under and completely surrounding pipes with concrete after they are laid and tested; in complete all as specified.
217M&L removing of surplus material n exc 50m and deposited where directed at a level not exc 1.5m above the starting point
218Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
219Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified.
220M & L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described over a coat of red oxied primer complete all as specified Total carried over to BOQ Rs. 11753157.7 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VII (Compound Wall, Fencing, Gates etc) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
221Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
222Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
223M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
224Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified.
225M & L for Removing excavated material exc. 50m but n exc. 250m and depositing where directed at a level n exc. 1.5 m above the starting point
226M & L for PCC (1:4:8) type D-2 mm graded stone aggregate as in foundation. Filling & mass concrete complete all as specified and directed.
227M&L for brick work with sub class 'B' flyash brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
228M&L for rendering 15 mm thick in cement mortar 1:4, on fair faces of brick or concrete surfaces, and surfaces finished even and fair complete all as specified.
229Ditto, all as per item no. 8 above on other than fair faces of brickwork.
230Material & Labour for applying Two coats of acrylic emulsion paint, Alkali & fungal resistance, dirt resistance exterior paint of required shade over and including priming coat of exterior primer over new surfaces complete all as specified & directed.
231M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
232M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
233M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
234M & L for Form work to sides of foundation / base of columns plinth beams and similar work with fair finished surface complete all as directed.
235M & L for Form work to sides of columns and similar work with rough finished surface complete all as directed.
236M & L for Form work to sides of beams and soffit with rough finished surface complete all as directed.
237Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
238Ditto as item no.17, but 5mm dia and over upto and including 10mm dia in stirrups, spacers,distribution and binders
239Providing precast cement concrete louvres and jallies,25mm thick (measured solid), including all mould- ings butexcluding frame
240M & L for Gate and fixed complete all as specified Total carried over to BOQ Rs. 15582250.16 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VIII (Rain Water Harvesting) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
241Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
242Earthwork in excavation by mechanical means over area in any kind of soil (exceeding 30 cm deep' 1.5 m in width as well as excedding 10 Sqm in plan area) including getting out and disposal of excavated earth lead up to 50 m and lead upto 1.5 m complete all as specified an das directed.
243All as per item No 2 above but exc 1.5 m but not exc 3 m deep
244All as per item No 2 above but exc 3.00 m but not exc 4.5 m deep
245All as per item No 2 above but exc 4.50 m but not exc 6.0 m deep
246M&L for PCC 1:4:8 type D-2 using 40mm graded stone agg as in fdn filling, mass concrete etc complete all as specified.
247M & L for Brick work with Sub class 'B' bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified.
248M & L for PCC 1:2:4 mix type B1 using (20mm graded stone aggregate) as in coping complete all as specified.
249100 mm thick PCC 1:2:4 type B 2 (40mm graded aggregate) as in sub base complete all as specified.
250M&L for 15 mm thick cement plaster in CM 1:4 on walls surface or concrete incl finished surfaces shall be even and smooth without using extra cement complete all as specified.
251RCC Pipe 300mm bore dia in class NP-2 laid and jointed complete with collars all as specified and directed.
252M&L for loose filling with broken stone or boulder aggregate of gauge 80-150 mm as in filter bed complete all as specied.
253M&L for loose filling with broken stone or boulder aggregate of gauge 40 as in filter bed complete all as specied.
254M&L for coarse sand filling under floors or in foundations including watering and consolidation
255Precast RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in cover slab and similar work includind necessary formwork set in cm 1:4 complete.
256M & L for mild steel bars 10mm dia & over cut to length bent to shape required including,crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, quality confirming to TMT bars
257Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified.
258Removing excavated material exc 250m but not exc 500 m and depositing where directed by Engr-in-charge at a level n.exc 1.5m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 1457136.61 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IX ( Sewage treatment Plant ) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
259M&L 3-layer PP-R Polypropylene random copolymer concealed pipes 110 mm o/d SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings laid in trenches
260M&L 3-layer PP-R Polypropylene random copolymer concealed pipes 50 mm o/d SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings laid in trenches
261Supplying and laying of CPVC pipes with supplying and laying of CPVC pipes SDR-11 and plain CPVC SDR 11 fittings walls/ceiling or laying in floors of outer diameter 50 mm complete all as specified. Total carried over to BOQ Rs. 320655.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part X (Concealed LAN conduiting) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
262Supply , fixing rigid non metallic PVC conduit fixed conceiled/on wall wherever necessary with all connected accessories 20 mm dia for LAN connections complete all as specified and as directed
263Supply , fixing rigid non metallic PVC conduit fixed conceiled/on wall wherever necessary with all connected accessories 20 mm dia for LAN connections complete all as specified and as directed Total carried over to BOQ Rs. 1919563.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XI (Split AC) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
264supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.0 ton
265Supply and fix air cooled split unit air conditioner indoor/outdoor complete with cordless remote control unit and in built air ioniserand plasma filter for better indoorair quality of capacity 2 ton( for Server Room each wing)
266Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps,230V, 50 Hz Total carried over to BOQ Rs. 29397303.26 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XII (Lift) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
267Design , install,testing and commissioning of 16 passenger lift, speed 1.5 meter/sec with single speed motor 415 volt, 3 phaseAC 50 Hz suply confirming to IS 14665 and amended suitable to serve S+5 upper floor with AC variable freequency drive(VVVF drive) complete with all standard accessories , simplex automatic and manual dual controlled operation with/without attendant, centre opening doors with door drive(electric motor driven mechanism), sliding stainless steel doors, automatic rescue device(ARD) system, 3D infra red sensor in full height of door and built in announcing system without hand set(03 Nos one in each car,machine room and near ground floor landing door) complete all as specified and directed.
268Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core ( from wing Sub Stn / DG panel to Lift room)
269Excavation in trenches, n. exc. 1.5 m wide and n.exc 1.5 m in depth ;for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc.n. exc. 10 sq m on plan and n. exc. 1.5 m in depth and getting out soft/loose soil all as specified and as directed.
270M&L fine sand cushioning for cable protection in layers incl punning all as specified and directed. Note : Punned down thickness shall only be measured.
271Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and as directed.
272Returning, filling in, trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cm Soft / loose soil all as specified and as directed.
273Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5m above the starting point all as specified and as directed. Total carried over to BOQ Rs. 39951558.7 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XIII (Lighting Protection) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
274Supply and fix single pointed air termination aluminium rod , 12 mm dia, 300mm long complete all as specied.
275Supply and fixing aluminium strip 25mm x 3.15 mm complete with saddles and fixing screws as roof conductor complete all as specified.
276Supply and fixing GI strip 32 mm x 6 mm complete and buried in ground as ground conductor complete all as specified .
277Supply and fix Tubes light grade galvanised of size 40 mm with all fittings and fixed complete for suuporting the air temination rod and protection of GI strip complete all as directed
278M & L for PCC (1:2:4) type C-1 (using 20 mm aggregate) as fixing of pipe on roof for air teriminators etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and as directed.
279M & L for Test point terminal block made of gun or phosphorus bronze size 75 x 75 x 25 mm, drilled and secrewed including 3 nos 8mm dia 25 mm long hex. Head screw complete all as directed complete. Total carried over to BOQ Rs. 519290.79 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XIV (Geyser) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
280Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated complete with all accessories such as safety valves, thermstat, NRV, connection piece etc ( for each offrs Accn)
281Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps,230V, 50 Hz Total carried over to BOQ Rs. 3258018.5 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XV (Water Cooler) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
282Supply and installed water cooler, Electric driven,(single phase 230 volts) having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour. complete all as specified. Total carried over to BOQ Rs. 764444.66 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XVI (Fire Fighting) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
283Supply and fix Pipe ERW Steel including specials, nominal dia 150 mm as per IS 3589 (1981) thickness 5.4mm
284Supply and fix Pipe ERW Steel including specials, nominal dia 100 mm as per IS 3589 (1981) thickness 4.8 mm
285Supply and fix hose box outdoor type for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 3.15 mm
286Supply, installaion, testing and commissioning of slim seal type cast iron butterfly valves , bronze/ Gun metal seat of size 100 mm dia, PN 1.6, lever operated type with necessary flanges, nuts, rubber insertion gaskets, nuts and bolts complete.
287Supply, installaion, testing and commissioning of non return valve 100MM horizontal type cast iron double flanged conforming to IS 5312 with bolts, nuts, washers, 3 mm thick insertion rubber gaskets complete as reqd.
288Supply, installatin, testing and commissioning of single hydrant valve of 63 mm dia single headed with instantaneous hose coupling adaptor with ISI mark. confirming to IS : 5290 lim seal type cast iron non return valves with flanges, unts, bolts and rubber gaskets for seating the valves complete.
289Supply and installation, testing and commissioning of of Inteliigent addressable manual call point with inbuilt turbo Isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra acceesories as required, duly ISI marked
290Supply and installation, testing and commissioning of Inteliigent addressable loop powered sounder , inbuilt turbo Isolator, able to provide an o/p of 88dBA at 1m, peak light o/p of at least 3.2cd and shall have 11 programmable tones, 3 volume settings selectable from the panel and fully synchronized with other sounders and shall have the ability to switch between one tone for alert and one tone for evacuation. Shall have protection category of IP42 and duly ISI marked
291Supply and fix Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector suitable for operation at min 7 zone complete all as specified and directed
292Supply and fix Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories complete all as specified and directed. Total carried over to BOQ Rs. 2905910.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XVII (Site Clearance) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
293Site Clearance work including cleaning of shrubs, vegetation, bush, weeds, trees and saplings not exceeding 30cm in girth(measured at height of 1m above GL) and useless material dispossed off upto a distance of 50m outside the pheriphery of area complete all as specified and as directed.
294Grubbing up tree trunk girth exc 100cm and n.exc 150cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site
295Grubbing up tree trunk girth exc 30cm and n.exc 100cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site Total carried over to BOQ Rs. 767784.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XVIIA (Internal Electrification) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.)
296M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- (a) One light point controlled by one, one way switch 5 Amps Point 992.75 6190.0 6145122.5 (b) One fan point/ exhaust fan/wall fan point controlled by one, one way switch 5 Amps and regulator Point 992.75 1880.0 1866370.0 (c) One light point controlled by , two way switch 5 Amps Point 1397.96 171.0 239051.16 (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. Point 284.1 1000.0 284100.0 (e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. Point 1070.4 1960.0 2097984.0 (f) One bell point controlled by one, bell switch 5 Amps Point 992.75 411.0 408020.25
297Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
298Description all as per item No. 1 here in before but using 4.0 sq mm single core copper conductor two nos FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly.
299S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete.
300S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
301S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
302S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified.
303S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
304S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
305S & F Bell push modular 6 Amps single module complete all as specified.
306S & F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
307S & F for Angular Holder wall mounted made out of PVC/ Policarbonate back plate and bipin holder made of brass to be fitted for LED bulb complete all as specified and directed.
308M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable,one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one unit
309M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit
310M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSHH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSHH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
311M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSh cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Four runs of 10 sqmm cable, one runs of 10 sqmm cable and one run of PVC conduit will be measured as one unit
312M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 10 sqmm cable,one run of 10 sqmm cable and one run of PVC conduit will be measured as one unit
313S & F for sheet metal enclosure MCB DB SPN 16 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
314S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
315S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
316S & F for MCCB four pole rated capacity 40 Amps,( nearest standard size ) 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed.
317S & F for MCB DP / SPN MCB rated capacity 16 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
318S & F for MCB DP/ SPN MCB rated capacity 32 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
319S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
320Supply and fixing ceiling fans complete with blades, down rods, electronic regulator modular type, remote control and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
321S & F for energy efficient exhaust fan of 300 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt , embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.
322S&F Exhaust fan made of sturdy engineering plastic complete with louvers shutter, 230 V, 50 Hz, 1200 RPM , copper winding fan single phase 250 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
323S & F surface mounted mirror light of capacity 5 watt, , 230 volts with CRCA housing with and intregrated electronic driver with luminous efficacy not less than 120 lumen/watt connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed.
324S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting,luminous efficacy not less than 120 lumen/watt 230 volts and intregrated electronic driver connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
325S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts , luminous efficacy not less than 110 lumen/watt LED Chip, Driver and housing should be of same make with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
326S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories with junction and other accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. Total carried over to BOQ Rs. 39468178.18 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer

AI Tender Summary

OUR REF NO 56949353
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 91.71 Crore
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Single Officer Accn For Student Officers Of Army War College Under Ge (Awc) Mhow
Basic Detail
Tender No 753061A PROVN OF SINGLE OFFICER ACCN FOR STUDENT OFFICERS OF ARMY WAR COLLEGE UNDER GE (AWC) MHOW
Bidding Type Tender
Location
City Indore
State Madhya Pradesh
Key Dates
Publish Date 11 Aug 2026
Submission Date 15 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 91.71 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
9e966a7b-687d-4a05-a326-0e047377b7ae.html
BOQ_878202.xls
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
html

9e966a7b-687d-4a05-a326-0e047377b7ae.html

xls

BOQ_878202.xls

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders