Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #56949348

Tender For Repair To Sewage Lines, Manholes And Cleaning Of Sewage Lines And Septic Tanks Etc At Zone A (Ftsu) Area Under Ge (Navy) Chennai

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
10 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
7 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair To Sewage Lines, Manholes And Cleaning Of Sewage Lines And Septic Tanks Etc At Zone A (Ftsu) Area Under Ge (Navy) Chennai

BOQ

Name of Work:- REPAIR TO SEWAGE LINES, MANHOLES AND CLEANING OF SEWAGE LINES AND SEPTIC TANKS ETC AT ZONE A (FTSU) AREA UNDER GE (NAVY) CHENNAI
Sl. No. Item Description
1Cleaning of septic tank of any capacity incl removing out the scum, silt residues both organic or inorganic type and removing the sludge etc to a distance upto the vehicle complete all as specified and directed by Engr-in-Charge.
2M&L for lifting of night soil with water using suitable pump attached with vehicle having tank of 10,000 liters capacity from septic tank ,soak well & manholes ( or from any other location as per direction of Engr-in-charge) and removing to suitable place out side MD land (Authorized civil location) Notes:(i)The above rate is inclusive of one driver with two man power with and including pumping arrangement attached to vehicle of ten thousand Liters capacity(ii)The above rate is inclusive of sucking pipe (upto 50m length) from place of lifting of night soil with water to pump attached with vehicle)(iii) In case vehicle is not arranged as per direction of Engr-in-charge, recovery at double the CA rate will be made.
3Cleaning/ maintenance of sewage system consisting of sewage lines of various sizes, floor/Nahani/gully traps, water closet of various sizes in buildings including removal of blockage/logging in sewage lines by by means of opening the oval access door, rodding complete and slightly cleaning the pipe with clear water and closing the oval access and stacking the silt/ sludge and removing from site at the distance exc 100m but not exc 750m located at Zone A all as specified and directed by Engr-in-Charge Note for Ser No 3(a) to 3(l): In case Daily manpower is not arranged as per direction of Engr-in-charge, recovery at double the market rate will be made.
4(a) CI/PVC vertical pipe 150/160 mm bore fixed to wall
5(b) CI/PVC vertical pipe 100/110 mm bore fixed to wall
6(c) CI/PVC vertical pipe 75 mm bore fixed to wall
7(d) CI/PVC Horizontal pipe 75 mm bore laying in ground / floors
8(e) CI/PVC/RCC Horizontal pipe 100/110 mm bore laying in ground / floors
9(f) CI/PVC/RCC Horizontal pipe 150/160 mm bore laying in ground / floors
10(g) CI/PVC/RCC Horizontal pipe 200 mm bore laying in ground / floors
11(h) Cleaning of nahani trape/floor trap/ Gully trap/ WCs of any size
12(j) Desilting of man hole up to 0.90 m deep
13(k) Desilting of man hole exc 0.91 to 1.50m deep
14(l) Desilting of man hole exc 1.51 to 2.50 Mtr deep by pumping from site to 300 Mtrs distance.
15Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in soft/loose soil, complete all as specified and directed
16M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified.
17Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles and removing rubbish from the site complete all as specified and directed.
18M&L for Brick work with old size fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
19M&L for Providing cement concrete 1:2:4 type B-0 (12.50mm graded stone aggregate) as in coping/ benching etc with plain fair faces, including chamfers, weatherings, throating etc. complete all as specified and directed.
20Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided and cement concrete is reinforced (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
21M&L for Precast cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) as in cover slabs (for man holes etc) chullah hoods, chajjas, water trough, shelves & similar articles with plain faces set in Cement mortar 1:6 etc complete all as specified and directed.
22S & F Mild Steel TMT bars 10mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
23All as per item No. 22 herein before but 8mm dia TMT bars
24Taking down cement plaster , any description, on brick walls or stone walls,etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
25M&L for rendering 15 mm thick on brick or concrete external wall surface in CM (1:4) and finishing the surface fair and even and using WPC 3% by weight of cement as per manufacturer instructions complete all as specified and as directed.
26Supply only integral water proofing compound
27M&L for DWCPE (SN8) of 200mm Inner dia , laid and jointed with solvent as manufacturer instructions laid in trenches etc including demolition and breaking up of old pipe line of any type with concrete bed of any size etc
28All as per Item No 27 herein before but 160mm inner dia DWCPE (SN8) pipe
29All as per Item No 27 herein before but 110mm inner dia DWCPE (SN8) pipe
30M&L for Concrete bed to drain pipes including packing under, & completely surrounding pipes with concrete as per SSR Part-I and Part-II after they are laid & tested in cement concrete (1:3:6) type C-2 bore of pipe 200 mm dia.
31All as per Item No 30 herein before but 160mm for SGSW/RCC/DWCPE pipe
32All as per Item No 30 herein before but 110mm for SGSW/RCC/DWCPE pipe
33M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 200mm dia pipe
34All as per Item No 33 herein before but 160mm bore
35All as per Item No 33 herein before but 110mm bore
36Returning filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25cm using approved excavated soil all as directed.
37Removing excavated soil to a distance exceeding 250 Mtrs but not exceedng 500m and depositing where directed at a level n.exc 1.5m above the starting point all as specified.
38Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
39Material and labour for Cement concrete type D2, 1:4:8 (40mm graded stone aggregate) 75 mm thick as in sub base complete all as specified and directed.
40Material and labour for M-sand cushoning laid over sub base for fixing inter locking tiles complete all as specified and directed.
41Material and labour for Machine pressed precast conctete interlocking glossy/ lacquer finish paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness including 2mm thick rubber mould glossy/ lacquer finish paver block of Grade M-35 and over sand cushion complete all as specified and directed. ( Note- Sand will be measured and paid separately)
42M&L for Chequered cement concrete coloured tiles 30cm x 30cm x 22mm thick set, jointed and pointed in neat cement slurry in floors and filled with grey/ coloured pigment etc complete all as specified and directed.
43Material and labour for 75 mm thick plain Cement concrete type B1, 1:2:4 (20mm graded stone aggregate) as in flooring finishing even and fair surfaces complete all as specified and directed.
44Supply and Fix in repairs for 160mm dia PVC pipe single socketed in any length with rubber joints fixed to walls with Stack clamps out of 50 mm by 5 mm flat iron and 6 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof including necessary scaffolding up to height G+8 complete all as specified and directed.
45All as per item No. 44 herein before but 110mm bore pipe complete all as specified and directed.
46All as per item No. 44 herein before but 75 mm bore pipe complete all as specified and directed.
47All as per item No. 44 herein before but refixing of 160 mm bore pipe ditto all complete all as specified and directed.
48All as per item No. 44 herein before but refixing of 110 mm bore pipe ditto all complete all as specified and directed.
49Supply and Fix PVC bends/shoes any radius bore of dia 160mm complete all as specified and directed.
50Supply and Fix PVC bends/shoes any radius bore of dia 110mm complete all as specified and directed.
51S&F PVC bends any radius bore of dia 75 mm with access door all as specified.
52Supply and Fix PVC bends any radius bore of dia 110mm with access door complete all as specified and directed.
53Supply and Fix PVC (SWR) branch piece, single/ double T) equal or unequal of 110 mm with access door complete all as specified and directed.
54All as per item No.53 herein before but 75 mm bore pipe complete all as specified and directed.
55Supply and Fix for PVC (SWR) vent cowl of 110 mm complete all as specified and directed.
56Supply and Fix for 110mm PVC( SWR) WC connector with lip ring.of reqd length complete all as specified and directed.
57Supply and Fix for 75 mm dia outlet PVC (SWR) multi floor trap with grating including jointing with solvent cementcomplete all as specified and directed.
58Dismantling floor hearth or wall tiling including cement mortar bedding and rubbish off the premises all as specified and as directed.
59Material and Labour for Non- skid ceramic coloured tiles 7 to 8mm thick (square/Rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6.complete all as specified and directed
60Material and Labour for glazed ceramic coloured design tiles 450x300mm x 7mm thick in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick backing coat of CM 1:4 etc complete all as specified and directed
61M&L for 10mm thick rendering on roof top surfaces in CM 1:3 using WPC @ 3% by weight of cement incl finishing the surfaces even and smooth and including taking down existing plaster surface and opening of cracks and cleaning of existing surface with water etc complete all as specified and directed.
62M&L for Cleaning of roof top/sunken floor surfaces, new or old and cleaning/ cutting of existing cracks and filling of Dr fixit Code No 190 Roof seal flex and applying one or more coat of Dr fixit Code No 148 Roof seal @ 0.9 ltr/ Sqm complete all as specified and directed.
63M&L for PCC 1:7:12 type F2 using brick coarse aggregate as in sunken slab and applying a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm on plastered surfaces over a coat of primer (Priming surfaces and applying normal treatment (for moderate condition) using glass fibre base bitumen felt, grade2) including Cleaning the side/bottom of sunken floor with wire brushes, drying to receive the water proofing material and applying pidilite/Aqualite in the sunken portion (floor/sides) as per manufactures instructions and directed by Engineer-in-charge and testing for leak proof complete all as specified and directed.
64S&F in repair of vitreous china squatting pan 'Orissa pattern' size 580 x 440 mm white with integral foot rest including replacement of 'P' or 'S' CI trap, lime concrete bedding and making good floor complete all as specified and directed by Engr-in-Charge
65S&F in repairs EWC Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but incl heavy duty seat cover complete set complete all as specified.
66Supply and Fix in repair low level flushing cistern 10 ltrs capacity body moulded from virgin quality high impact poly propylene and functional parts moulded from ABS nylon and nylon gland complete incl brackets and 15mm bore 450mm long PVC water connection all as directed.
67Supply and Fix in repair for Fancy type CP stop/angular cock 15mm dia cast copper alloy, chromium plated fency type screwed down high pressure with half turn of capstan heads, screwed both end for iron pipe or for unions and fixed. complete all as specified and directed
68Supply and Fix in repair for Fancy type CP bib taps15 mm dia ,chromium plated cast copper alloy with half turn type capstan heads, screwed down screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed
69S&F for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
70S&F in repair for Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engr-in-Charge
71Removal of demolished materials/debris to out side MD land a distance n exc 5.00 KM etc complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56949348
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Sewage Lines, Manholes And Cleaning Of Sewage Lines And Septic Tanks Etc At Zone A (Ftsu) Area Under Ge (Navy) Chennai
Basic Detail
Tender No 8835/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 11 Aug 2026
Submission Date 31 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value 10 Lakhs
Tender Fee 500
EMD 20000
Exemption Available
Document List
8835GENERALPAGES.pdf
8835PS.pdf
8d7a6889-7539-432c-b6d2-3ba3ba043a33.html
BOQ_878253.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

8835GENERALPAGES.pdf

pdf

8835PS.pdf

html

8d7a6889-7539-432c-b6d2-3ba3ba043a33.html

xls

BOQ_878253.xls

pdf

Tendernotice_1.pdf