Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56948649

Tender For Repair And Maintenance Of Workshop Block At Govt Iti Pampore.

Issued by Government Departments · Pulwama, Jammu and Kashmir
Tender Value
18.43 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
6 days left
EMD
36860
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Workshop Block At Govt Iti Pampore.

BOQ

Name of Work:-
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
2Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:Rate for a lead upto 1 meter fromcutting edge All kinds of soil :
3Providing & Laying of GSB/RBM/stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
4Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
5Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
6Centring and shuttering including proping, strutting & removal of the same for foundation footings base of columns etc.
7Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
8Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
9Demolishing brick work manually/by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
10Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
1112mm Cement plaster finished with a floating coat of neat cement of mix:1 : 4 ( 1 cement : 4 fine sand)
12Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
13Supply and filling of GSB/Quarry material of specified and required size as directed including dressing, ramming watering and compacting with carriage of all material involved loading, unloading and stacking complete.
14Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
15Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown
16Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
17Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work.
18Structural steel work in built up sections, trusses, framed wk incld cutting hoisting fixing in positon and applying a priming coat of approved steel primer all complete i/c soffits / eaves boarding (welded)
19Engagement of Carpenter for removing the existing almirahs, wardrobes, shelves etc. at site and refixing of the same after all the necessary changes as directed by EIC complete job, quantities are anticipated and shall be paid as per actual as certified by concerned AEE.
20Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 meters lead : Of area of 3 sqm. and below
21Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 meters lead : Of area beyound 3 sqm.
22Providing and fixing 19mm thick plyboard (7-ply) semi-waterproof, including cost of nails and adhesive, complete job.
23Providing and fixing 12mm thick plyboard (5-ply) semi-waterproof, including cost of nails and adhesive, complete job.
24Dismantling steel work in single sections including dismembering andstacking within 50 meters lead in : R.S. Joists
25Engagement of Carpenter for Repairs of Damaged Door and windows etc as directed by EIC, quantities are anticipated and shall be paid as per actual as certified by concerned AEE.
26Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position. KD wood German quality.
27Providing and fixing 35mm thick panelled door shutters, including ISI marked black enamelled M.S. Butt hinges with necessary screws including panels complete. (KD wood of German quality).
28Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.
29Providing Float glass panes 3.50 mm thick ) cleresty window shutters (Area of opening of glass panes excld position inside shall be measured)
30Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality, 1 mm thick
31Carriage of materails By Mech.Transpt, from source to site of work.
32Sand and Stone agg. for an avg lead of 5km
33Electrification.
34Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor Havell/Polycab/Anchor/eq,standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit, with modular switch (Anchor ramn plus/ Legand Mylinc /SSK NV/Schnelder/ABB Tvisho make) moduar plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc. as required.as approved by EIC.
35Wiring for light point/ fan point/ exhaust fan point/ call bell point without independent switch etc) with 1.5 sq.mm FRLS PVC insulated copper conductor (Polycab/Green/Havel life/Anchor/eq,standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit, Excluding the cost of conduit as required.as approved by EIC.
36Supplying and fixing suitable size Gl box with modular plate and cover In front on surface or In recess, Including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable Gt box, connections etc. as required. Modular Switch & Socket:-Antibacterial series (Legrand/ABB/Slemens make.)
37Wiring for light/ power plug with 2X4 sq. mm 1X 4 sq. mm earth wire, FRLS/HFFR PVC Insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer Incharge )) single core cable in surface/recessed medium class PVC conduit.including cutting the wall and making good the same In case of recessed conduit as
38Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, Including providing and fixing 3 pln 5/6 A modular socket outlet and 5/6 A modular switch, Antibacterial series ( Legrand/ABB/Siemens make.)connections etc. as required.
39Supplying and fixing suitable size Gi box with modular plate and cover In front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- Antibacterial series (Legrand/ABB/Siemens make)
40Wiring for circult/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC Insulated copper conductor (Polycab Green/Havell Life guard/Fenolex/Salzer/RR/Apar make as desired by engineer Incharge), single core cable in surface/ recessed medium class PVC conduit as required.(Excluding the cost of conduit).
412 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
422 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
432 X6 sq. mm +1 X 6 sq. mm earth wire
442 X 10 sq. mm + 1 X 6 sq. mm earth wire
452 X 16 sq. mm + 1 X 6 sq. mm earth wire
464 X 10 sq. mm + 2X 6 sq. mm earth wire
47Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
48Supplying and fixing of following sizes of medium class PVC condult Anchor/ Ravindra/ Eq. make) along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty, paint, complete
4925 mm
5032 mm
51Supply and fixing of 25mm wide Medium Class PVC casting & Capping (FRLS type) with necessary accessories such as saddles, couplers, tees, bends and junction boxes, complete as per specifiction.
52Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (But without MCB/RCCB/Isolator). (legrand/Schinider/L&T./ABB/equivalent standard make as directed by engineer Incharge.)
536 way (4418), Double door
54LED Supply installation testing and commissioning of 18 W+ Surface/recess, Mounted light luminary fitting square or round shape with minimum system lumen efficacy ≥ 120 Im/Watt with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95, THD<10%, CCT 5700K, CRI 80 The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V. The Fixture should have In-built Surge Protection of 2kV. Certification: LM79 & LMSO test report should be from govt approved In-house NABL lab/government of India. The job Includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years which includes replacement of fixtures of Philips/Helonix/Wipro/Regent make/sample to be approved before Installation....
55S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt + 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of ≥ 120 Im/Watt with Pressure Die cast Aluminium Heat Sink and P.F.>0.95, THD 10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at 170, separate driver, heat sink, earthing provision. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification: - LM79 & LM80 test report should be from Govt. approved in-house NABL lab/ government of India. Philips/ Helonix /Wipro make. sample to be approved before Installation.
56S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve/ Schinider Acti 9/ L&T./ABB make as directed by engineer incharge.
57(a) 6-32 Amp SP MCB
58b) 40-63amp DP MCB
59b) 40-63amp TΡΝ MCB
60Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton make as directed by engineer incharge, Including making of space in wall/ window as per site requirement and necessary connections.
61Supply, Installation, Testing and Commissioning of 1200 mm sweep, celling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos, canopies, shackle It, Power Factor not less than 0.9, Service Value Including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), Insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and Including iron hook complete. USHA/Havells/Crompton/orient make as directed by engineer incharge.
62Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box Including connections but excluding modular plate etc. as required. Antibacterial series (Legrand/ABB/Siemens make.
63Supply fixing testing and comm. Of backlite holder/batten holder/angle holder/ceiling rose SSK/Anchor make Incl. PVC Block.
64Engaging of skilled labour for shifting of main panel from the existing place to the adjacent room and Dismantling of old damaged materials like wires In scraps, fixtures switches-sockets, panels, complete as directed by the engineer at site and stacking and handing over to concerned department Including carrying out some repairing works etc.
65Providing of Chemical earthing as per 15 standards by way of digging 10 deep pit then embedding 3 meter G.l Earthing electrode, 80mun dia. connecting the plate with main control board by 10 SWG copper wire with 1/2\\" dis. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
66Supply, laying (partly underground/partly overhead) testing and commissioning of PVC alluminium un-armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer Incharge and making end termination with brass compression gland and aluminium lugs of required size.
67(d)95 sq.mm 3.5 core (Armoured) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56948649
AUTHORITY Government Departments
TENDER VALUE 18.43 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repair And Maintenance Of Workshop Block At Govt Iti Pampore.
Basic Detail
Tender No 90/EEA/RNB of 2026-27/4663-73 Dated 11-08-2026
Bidding Type Tender
Location
City Pulwama
State Jammu and Kashmir
Key Dates
Publish Date 11 Aug 2026
Submission Date 24 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 18.43 Lakhs
Tender Fee 800
EMD 36860
Exemption Not Available
Document List
b138d4ba-d59e-4409-bf3b-6611637242db.html
BOQ_1065586.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

b138d4ba-d59e-4409-bf3b-6611637242db.html

xls

BOQ_1065586.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail