Tender For Comprehensive Maintenance Of Central Ac Plant 3 X 37.5 Tr Located At Dcn Palam And Repair/Maintenance Of Cooling Tower And Connected Works And Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Pala
Tender Overview
Project Description
Tender for Comprehensive Maintenance Of Central Ac Plant 3 X 37.5 Tr Located At Dcn Palam And Repair/Maintenance Of Cooling Tower And Connected Works And Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Under Ge(U) P&M, Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Periodical, preventive and comprehensive maintenance of Central Air conditioning plant of capacity 3 x 37.5 TR as per manufactures manual of preventives and comprehensive maintenance and with periodicity mentioned there in as per particular specification installed at DCN PALAM daily including Saturday, Sunday and Gazetted Holidays complete all as specified and directed by Engineer-in-Charge at Delhi Cantt .Notes for Item No 1.00 :-(a) Periodical, preventive and comprehensive maintenance complete package chiller units 03 Nos, each consisting of 1 No 37.5 TR along with motor and its condenser,compressor, chillers, microprocessor based control panel complete system done through OEM i.e. any one of M/s Blue Star/Trane/Voltas/ Hitachi including submission of quarterly service reports from OEM. Total No. Chiller units-03 Nos.The comprehensive maint of contral Air coditioning plant under this contract shall be done through manufacturer The contractor will have to submit MOU on stamp paper of Rs 100/- duly notarized as per performa with in 15 Days from date of acceptance of tender, failing of which the contract will be liable to be cancelled & work will executed as per policy invouge of the contractors default.(b) Preventive, comprehensive and routine maintenance of following equipments :-Details of the AC Plants:- (a) Centrifugal Monoblock Pumps set for Hot water Circulation Cap of 3 Hp, Make- Crompton – 02 Nos.(b) Centrifugal Monoblock Pumps set for Condenser water Circulation Cap of 5 Hp, Make-Kirlosaker - 03 Nos(c) Monoblock pumps for chilled water Circulation of cap 3Hp -03 Nos. (Make - Crompton).(d) Scroll Type Commercial Compressors Cap of 12.5 TR Make- Danfoss, Model No- SZ185S4RC -09 Nos (e) Scroll Water Chiller, Make- Blue Star Cap of 37.5 TR Refrigerant – 407 C Model No- XWC3S039AR2 -03 Nos. (f) Hot Water Generator Cap of 75 KW Make- Rapid Cool S.No- 195AC,HO19 -02 Nos.(g) FRP Induced Draft Cooling Tower Cap of 75 TR Make- Mihir , Model No- FH4 - 02 Nos.(h) Double Skin Horizontal Mounted Air Handling Unit Cap of 29000 CFM, Make-Edgetech Air System Model- ETU300H, Coil-CHWCoil/ 1016 x 2653 / 6RD & Heating Coil / 1016 x 26532RD, Fan Model-Kruger / DIDW Backward / 1000, Motor- Siemens / 18.5 KW - 01 Nos.(j) Main HVAC Panel -01 Nos.(k) In case of break down, the additional manpower if required will be arranged by the contractor. The cost will be deemed to be included in Sch “A” items. Please Enable Macros to View BoQ information |
| 2 | Periodical, preventive and comprehensive maintenance of Central Air conditioning plant of capacity 3 x 37.5 TR as per manufactures manual of preventives and comprehensive maintenance and with periodicity mentioned there in as per particular specification installed at DCN PALAM daily including Saturday, Sunday and Gazetted Holidays complete all as specified and directed by Engineer-in-Charge at Delhi Cantt .Notes for Item No 1.00 :-(a) Periodical, preventive and comprehensive maintenance complete package chiller units 03 Nos, each consisting of 1 No 37.5 TR along with motor and its condenser,compressor, chillers, microprocessor based control panel complete system done through OEM i.e. any one of M/s Blue Star/Trane/Voltas/ Hitachi including submission of quarterly service reports from OEM. Total No. Chiller units-03 Nos.The comprehensive maint of contral Air coditioning plant under this contract shall be done through manufacturer The contractor will have to submit MOU on stamp paper of Rs 100/- duly notarized as per performa with in 15 Days from date of acceptance of tender, failing of which the contract will be liable to be cancelled & work will executed as per policy invouge of the contractors default.(b) Preventive, comprehensive and routine maintenance of following equipments :-Details of the AC Plants:- (a) Centrifugal Monoblock Pumps set for Hot water Circulation Cap of 3 Hp, Make- Crompton – 02 Nos.(b) Centrifugal Monoblock Pumps set for Condenser water Circulation Cap of 5 Hp, Make-Kirlosaker - 03 Nos(c) Monoblock pumps for chilled water Circulation of cap 3Hp -03 Nos. (Make - Crompton).(d) Scroll Type Commercial Compressors Cap of 12.5 TR Make- Danfoss, Model No- SZ185S4RC -09 Nos (e) Scroll Water Chiller, Make- Blue Star Cap of 37.5 TR Refrigerant – 407 C Model No- XWC3S039AR2 -03 Nos. (f) Hot Water Generator Cap of 75 KW Make- Rapid Cool S.No- 195AC,HO19 -02 Nos.(g) FRP Induced Draft Cooling Tower Cap of 75 TR Make- Mihir , Model No- FH4 - 02 Nos.(h) Double Skin Horizontal Mounted Air Handling Unit Cap of 29000 CFM, Make-Edgetech Air System Model- ETU300H, Coil-CHWCoil/ 1016 x 2653 / 6RD & Heating Coil / 1016 x 26532RD, Fan Model-Kruger / DIDW Backward / 1000, Motor- Siemens / 18.5 KW - 01 Nos.(j) Main HVAC Panel -01 Nos.(k) In case of break down, the additional manpower if required will be arranged by the contractor. The cost will be deemed to be included in Sch “A” items. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender