Tender For Construction Of Office Building Of Assistant Labour Officer, Pallahada, Dist.- Anugola Buildings.
Tender Value
1.61 Crore
Estimated cost
Bid Submission
25 Aug 2026
8 days left
EMD
1.61 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dhenkanal → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Office Building Of Assistant Labour Officer, Pallahada, Dist.- Anugola Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKClearing and grubbing land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto a lead of 1000metres including removal and disposal of top organic soil not exceeding 150mm in thickness as per Clause 201 of MoRT&H Specifications for Road & Bridge works Latest Revision & including cost of all labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 2 | Earth work excavation in foundation trenches in all kind of soil including dressing and leveling the bed up to required depth and depositing the excavated materials at places away from work site within 50mtr initial lead and 1.5mtr initial lifts T&P shoring shuttering dewatering if required etc. complete as per direction of the Engineer-in-charge. |
| 3 | From 1.5 Mtr upto 3.0 Mtr Depth |
| 4 | Supplying and stacking of good earth at site obtained from approved borrow pits including including carriage by mechanical means from within a specified Lead from from the site, including loading, unloading to approved dumping ground or as approved /directed by Engineer-in-charge, including cost of equipments/ labour, conveyance, royalty, T&P etc. as per the direction of Engineer-in-charge. |
| 5 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge. |
| 6 | Supplying filling in foundation and plinth with sand in layers not exceeding 150mm thick including watering, ramming including cost, conveyance, royalty and taxes of all materials, all labour T&P required for the work etc. complete (measurement will be taken on finished compacted section only). |
| 7 | Cement concrete of propertion (1:3:6) in foundation and floors using 40mm nominal size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royalty taxes of all materials and all labour T&P required for the work etc. complete as per direction of the Engineer-in-charge. |
| 8 | Cement concrete of propertion (1:2:4) in foundation and floors using 12mm nominal size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royalty taxes of all materials and all labour T&P required for the work etc. complete as per direction of the Engineer-in-charge. |
| 9 | Terrace |
| 10 | Providing G.S.B. Gr-vi stone screaning materials, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, as per approved Drawing & Technical Specifications and as per Clause - 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, royality & other taxes of materials, cost of labour, machinery, T&P etc complete. |
| 11 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.(Ground floor) |
| 12 | RCC work of M-20 in all floors having a minimum compressive strength ( in work test) 200kg/cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 10mm size to 20mm size black hard crusher broken granite stone chips (10mm size 40% & 20mm size 60%) of approved quality & from approved quarry including hoisting lowering laying and compacting concrete with centering & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary and providing required No. of fan hooks as required including cost, conveyance, royalties and taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect but excluding cost of MS rod / Tor steel and binding wire and labour charges for bending binding and tying the grills.(In all Floors) R.C.C. foundation and footing bases of columns |
| 13 | R.C.C. Plinth beams |
| 14 | R.C.C. Beams, columns, grider and bressmer etc.Ground floor |
| 15 | First floor |
| 16 | Terrace |
| 17 | Roof slab Ground floor |
| 18 | First floor |
| 19 | Terrace |
| 20 | Staircase Ground floor |
| 21 | First floor |
| 22 | R.C.C. Lintels.Ground floor |
| 23 | First floor |
| 24 | Terrace |
| 25 | Chajjas Ground floor |
| 26 | First floor |
| 27 | Building Wall Ground floor |
| 28 | First floor |
| 29 | Terrace |
| 30 | Drain Wall |
| 31 | Drain Slab |
| 32 | Labour charges for straightening the coiled or bend up M.S. rod / HYSD bars confirming to Gr. Fe-500, cutting bending binding lapping placing welding etc. (Confirming to ISI specification) and jointing if necessary by lapping and tying the grills and placing in position as required for RCC work as per approved design hoisting lowering and laying in position including cost conveyance & taxes of M.S. rod / tor steel (Primary Producer like- SAIL/RINL/TATA/ JINDALSTEEL/ SHYAM STEEL) make) and binding wire of 18 to 20 gauge (as approved by the deptt.) weight of over lapping, couping, welded joints, spacer bar, chair, stage, hanger and binding wires shall not be considered for payment at all. Standard co-efficient of different size of the steel shall be considered. Welding & lapping should be confirming to relevant clause of IRC 1987 in all floors. Ground Floor |
| 33 | First floor |
| 34 | Terrace |
| 35 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Ground floor |
| 36 | First floor |
| 37 | Terrace |
| 38 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Ground floor |
| 39 | First floor |
| 40 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground floor |
| 41 | First floor |
| 42 | Terrace |
| 43 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground floor |
| 44 | First floor |
| 45 | Terrace |
| 46 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Ground floor |
| 47 | First floor |
| 48 | Terrace |
| 49 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.Terrace |
| 50 | Supplying, fitting, fixing of Vitrified Tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mmx600mm Colour/printed series of approved make in floors on 20mm thick bed of cement mortar (1:4) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, taxes, labour, labour cess T&P erc. required for the work complete in all respect as per direction of the Engineer-in-charge. Ground Floor |
| 51 | First floor |
| 52 | Supplying, fitting, fixing of Vitrified Tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mmx600mm Colour/printed series of approved make as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm cement plaster (1:3) jointed with white neat cement slurry mixed with pigment to match the shades of the tile including rubbing and polishing etc.complete with cost, conveyance, royalities and taxes of all materials labour, labour cess complete in all respect.Ground Floor |
| 53 | First floor |
| 54 | Supplying, fitting, fixing of Industrial Vitrified Tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 300mmx300mm Colour/printed series of approved make in floors on 20mm thick bed of cement mortar (1:4) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, taxes, labour, labour cess T&P erc. required for the work complete in all respect as per direction of the Engineer-in-charge. Ground Floor |
| 55 | First floor |
| 56 | Supplying, fitting, fixing of Industrial Vitrified Tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 300mmx300mm Colour/printed series of approved make as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm cement plaster (1:3) jointed with white neat cement slurry mixed with pigment to match the shades of the tile including rubbing and polishing etc.complete with cost, conveyance, royalities and taxes of all materials labour, labour cess complete in all respect.Ground Floor |
| 57 | First floor |
| 58 | Supplying, fitting & fixing of 35mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality with frame of 1st class hard wood including cost of all door fittings and fixtures,conveyance of all materials labour and T&P require for the work etc.compolete as directed by Engineer-in-charge.Ground Floor |
| 59 | Supplying fitting and fixing of two track UPVC sliding window / ventilator of approved make with 6mm thick glass of approved quality complete with frame, shutter and all fitting and fixtures etc. complete as per specification & direction of Engineer-in-charge. |
| 60 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixturesGround floor |
| 61 | Supplying fixing and fittings MS window grills, Doors, MS verandha grills and MS grill gate of approved design and drawing made out of MS flat and MS angle at work site with one coat of anticorrosive red oxide zink chrome primer including cutting holes in brick or RCC walls and fixing with CC (1:3:6) including cost conveyance royalty and taxes of all materials all labour T&P required for the work complete (payment will be made on weight basis only) |
| 62 | Providing, Fitting & Fixing of Stainless steel of 304 grade in hand Railing of 50mm outer diameter of 2mm thick of approved Quality & Specification with balustrade of size 32mmX32mmX2mm square pipes in rows including Cost,conveyance of all Materials, Labour ,T&P required for fabrication, buffing & polishing, cost of all fixtures etc. complete and as per specification & direction of Engineer-in-charge (In all floors) |
| 63 | Providing and Painting two coats with synthetic enamel paint of approved make, quality and shade on new Steel work to give an even shade over an under coat of primer of approved brand and manufacturer including the cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, T&P, etc, all complete as per the direction of Engineer-in-charge.(Note- colour and shade shall be approved before procurement and use.)Ground floor |
| 64 | First floor |
| 65 | Terrace |
| 66 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground floor |
| 67 | First floor |
| 68 | Terrace |
| 69 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.Ground floor |
| 70 | First floor |
| 71 | Terrace |
| 72 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.Engineer-in-charge.Ground floor |
| 73 | First floor |
| 74 | Terrace |
| 75 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. Ground floor |
| 76 | First floor |
| 77 | Terrace |
| 78 | Supplying, fitting and fixing of 80mm thick cement concrete interlocking paver block of M40 grade of approved make, design, colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP 63:2018 including cost of all materials with all taxes and cost of all labour with T&P required for the work etc. complete in all respect as directed by Engineer in Charge. |
| 79 | EI WORK Internal WiringRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS-H PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. Group-A -L.P- 34 |
| 80 | Group-B L.P-34 FP - 6 |
| 81 | Group-C L.P-22,FP-8 ExFP-8, C B P-2 |
| 82 | Supply and fixing of 5 Amp plug with switch on existing board (Modular type/cover including connection etc. as required ) |
| 83 | Supplying and fixing of 3 nos 6 Amp Plug point 3 nos switch, 1 No 15 Amp Switch & 1 No 15 Amp Socket Modular type on modular metal box, base & cover with all connections.(Make-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) |
| 84 | Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 85 | Supply and fixing of metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing of 6pin 5/6 & 15/16Amp socket outlet and 15/16Amp piano type switches connection painting etc. as required. (make-Anchor/ Cona/HPL) |
| 86 | s/f of ac point consisting of 32A starter with all connection compelete s per the direction of engineer in charge |
| 87 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 88 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 89 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB complete with connections as per direction of Eng.-in-Charge. Warranty on MCB is 1 years. |
| 90 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years. |
| 91 | Supplying and fixing 32Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M,10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 92 | Recessed wiring to submain in the following sq.mm FRLS-H PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required.(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard//HPL) 2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20 mm dia |
| 93 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm -do- |
| 94 | 2 X 4 sq.mm +1 X 1.5 sq.mm -do- |
| 95 | s/f of 1.5 mm2 for inverter wiring |
| 96 | Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required. |
| 97 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose .as per direction of Engineer in Charge |
| 98 | s/f of tube light 18watt /20 watt led fitting with cover( Make-Bajaj/ Philips as per the direction of side engineer in charge) |
| 99 | S/F of 18 W Surface mounted LED downlighter with white powder coated aluminium housing with integrated electronic driver.(Make-Philips/havells/Bajaj/Crompton/Equivalent) |
| 100 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/ Crompton/ Usha/ Orient/ Bajaj) of exhaust fan in the existing wall, including fixing & connection as required as per direction of Eng.-in-Charge. Replacement Warranty will be 2 years. |
| 101 | Supply ,Installation, Testing and Commissioning following fan. A.C Ceiling fan 48\\" size. (Make-Usha-allure/Orient PSPO Summer cool Breeze/havells velocity/equivalent) |
| 102 | Supply and fixing of Electronic Type fan regulator (Make-Cona/ Anchor/ Usha/Bajaj) |
| 103 | Supply & fixing of 45 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories etc. as required as per direction of Engg.-in-Charge.etc. as required as per direction of Engg.-in-Charge. |
| 104 | Supply and fixing of Special Coper Plate (600*600*3.15mm with running coper flat 25*5mm long) Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per thevdirectuion of the side engineer incharge |
| 105 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required |
| 106 | Supply, Installation, Testing, and Commissioning of 40/63 Amp ICDP Main switches (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, nterconnections, earthing, etc. as required as per direction of Engineer in Charge |
| 107 | SITC of 1.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi) |
| 108 | REFRIGRANT PIPINGSupply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 109 | FRAME WORKSupply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 110 | DRAIN PIPINGSupply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe |
| 111 | Supply and fixing of 5kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 112 | S/F of 2.5 KVA/ 24 Volt Pro UPS sine wave inverter (Make-Luminious / Microtek / Livguard/Equivalent) |
| 113 | S/F of tall tubular battery of 150 AH (Make-Exide/Luminious/Livguard/Equivalent) |
| 114 | S/F of trolley for battery |
| 115 | Supply of 25 sq mm 3-1/2 core PVC Armoured cables ISI marked.(Make-Havells/Polycab/KEI/Equivalent) |
| 116 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells/ KEI/Gloster/Finolex/RR Kabel)3.5C X 35 sqmm |
| 117 | Laying of cableLaying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required.Upto 25 sq. mm |
| 118 | Above 25 sq. mm and upto 120 sq. mm |
| 119 | S/F of 30x24x10 no 16/18 SWG sheet metal for main 125 amp panel board having 125 amp FP MCCB 1no.,63A FP MCCB 1no.,125A electrolyte cu bus bar 1set with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 120 | S/F of 12x18x10 no 16/18 SWG sheet metal for main 63 amp panel board having 63 amp MCCB 1no., as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 121 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 122 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 123 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 124 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 125 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 126 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 127 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 128 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 129 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 130 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 131 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 132 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 133 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 134 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 135 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB |
| 136 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 137 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 138 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 139 | Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 140 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 141 | Fire Fighting SystemSupply & fixing of Terrace tank (5000 ltr) Fiber Water tank triple layer unbrakable extra thick and flexible material for long life new UV threaded lid to keep dustparticles out with all needed accessories. (make-intex/Ashirvad/Supreme) |
| 142 | Supplying, Installing, testing and commissioning of C.I. wafer type butterfly valves as per BS 5155 slim seal standared lever operated type with required flanges,nuts, bolts etc. complete. Make-Audco/Zoloto/Leader. 100mm nominal dia |
| 143 | Supply , installation ,testing and commissioning of Isolation Sluice valves tested to ISI marked ,PN 1.6 with CI body, bonnet & brass trim parts, & having necessary companion flanges, bolts, nuts, gasket including indicator for open and shutposition to be installed. (Make-Kartar) 100mm NB |
| 144 | Supplying, installing, testing and commissioning of C.I. waffer type Non-return valves ( PN 16 ) swing check type with required flanges, nuts, bolts and gasketsetc. complete. Make-Audco/Zoloto/Leader. 100mm NB |
| 145 | Supply and installation testing and commissioning of Pressure gauges of suitable range (0-16 bar), 100 mm diameter dial for pumpsets completes with necessary Ball valves, siphon, Fittings like unions / colors / reducers etc. Make- H Guru/GGuru. |
| 146 | Supply and installation testing and commissioning of differential Pressure switches of suitable range (0 to 12 bar) for pumpsets complete with necessay Ball valves, Fittings like unions / colors / reducers etc. Make- Danfoss/Grundfoss/Indfoss. |
| 147 | Supply, Installation of structural steel like ( Beam , Channel, Angle, Plate & Sheet) made of size min 100mmx50mm channel of thickness minimum 6mm and also tank base plate of thickness 6mm for 2 nos terrace tank base & barricade .(Make-SAIL/JINDAL/TATA) |
| 148 | Supply, Installation,Testing and Commissioning of 1\\" Air Release Valve with allaccessories as per direction of Engineer-in-charge.(make-Kartar) |
| 149 | Supply, Installation,Testing and Commissioning of 2 - way fire brigade connectionwith all accessories as per direction of Engineer-in-charge.. |
| 150 | Supplying, installation testing and commissioning of the following. C class MS pipe as per IS 1239 with welded / flanged / with heavy clamps, hangers, brackets or pipe supports as required including MS pipe of shorter lengths, tapering connecting pieces, short or long bends, forged specials like sockets, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities. The pipes will have to be laid and fixed on walls, ceilings, into brick walls or RCC with lead anchor fasteners to the satisfaction of the Consultant/Client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes.Make TATA/Sail/Jindal 100mm NB |
| 151 | 80 mm NB |
| 152 | 25 mm NB |
| 153 | Supplying, erecting and commissioning of Hydrants Single headed hydrant valve as per IS 5290, made of SS with 63 mm dia instantaneous outlet of 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etccomplete. Make: Newage/Minimax/ Fireshield/Kartar. |
| 154 | SITC of SS short branch pipe with nozzle conforming to IS 903. Make:Newage/Minimax/ Fireshield/Kartar. |
| 155 | Providing & fixing 63mm dia 15 meter long RRL hose pipe as per IS 636 TYPE A TAC/ LFA approved of standard length of approved pattern and size including ss male and female Coupling duly bound with copper wire etc. complete(Make-CRC) |
| 156 | Supplying and fixing MS hose box of suitable size made of 1.6 mm thick MS sheet with double door arrangement , front door fixed with full glass and locking arrangement to accomodate two nos. 63 mm dia RRL hose reel , one no. branch pipe with powder coated and postal red finishing along with all accessories etc asrequired.The hose box size is 750 mm x 600 mm x 300 mm (MAke-Winco) |
| 157 | Supply and installation, testing and commissioning of NRV conforming to API 594/598 (dual plate check type) with CI body & trim part, PN 1.6 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved. (Make-KArtar)100mmNB |
| 158 | SITC of First aid Hose reel drum of 180° swinging type with 19mm dia Rubber braided hose of 30M. length with Ball Valve and 6mm diameter Shut off nozzle, complete. The hose reel shall conforming to IS 884 Make: Newage/Minimax/Fireshield.(Make-Mitras) |
| 159 | Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type. 25 mm nominal dia Make-Audco/Zoloto/Leader/KArtar. 25mm |
| 160 | 15 mm |
| 161 | Supply, Installation, Testing and Commissioning of electric motor driven Terracebooster pump capable to deliver 450 LPM at 36 mtr head ,7.5 HP, 3 phase.(make-Kirloskar) |
| 162 | Supply , Installation,Testing and Commissioning of MCC cum Starter control panel (7.5 HP)for Terrace pump sets with incomer and selector switch for standby and working and auto/manual operation and necessary annunciation asperdirection of Engineer-in-charge.(Make-Powertech) |
| 163 | Supply , Installation,Testing and Commissioning of Power cable (4 C X 10SQMM) as required for motor run from Panel of the pump system as per direction of Engineer-in-charge.(Make-Polycab/Havells/KEI/RR/Finolex) |
| 164 | Supply , Installation,Testing and Commissioning of Control cable (3C X 1.5SQMM) as required for establishing automation Panel of the pump system as per direction of Engineer-in-charge.(Make-Polycab/Havells/KEI/RR/Finolex) |
| 165 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc asrequired.Make-Safex/Fireshield/Ceasefire |
| 166 | 6 Kg ABC (Powder Type) Fire Extinguisher In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket andconforming to IS:15683 (Make-Safex/Fireshield/Ceasefire) |
| 167 | Supplying, installing, testing and commissioning of Addressable Manual Call Pointwith back box.Make-MorleyIAS/Bosch/Siemens/notifier |
| 168 | Supplying, installing, testing and commissioning of Analogue Addressable Looppowered Sounder with strobe light.Make-MorleyIAS/Bosch/Siemens/notifier |
| 169 | SIGNAGE Floor identification signage ( i.e., GROUND FLOOR etc) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x60cm. |
| 170 | Way to exit signage at each stair on every floor, indicating the direction of fireexit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. |
| 171 | Supplying and installing of in position the signages \\" FIRE ORDER\\" it should contain the following matter on 3mm thick \\"Opaque\\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3' x 4'. as per BIS Specification.a. A) evacuate the occupants by obeying fire exits / way to exit and emergency exits only and assemble at various assembly points. (B) if possible try to extinguish the fire by using nearest / suitable portable extinguisher or water from nearest wet riser. C) be calm and do not give any room from panic, walk, do not run. (D) if you encounter serious difficulty in evacuation, flat and try to attractattention of rescue team. |
| 172 | Fire hose reel (Size:6\\" X 4\\") |
| 173 | Fire extinguishers (Size:6\\" X 4\\") |
| 174 | Manual Call Point (Size:6\\" X 4\\") |
| 175 | 10 PASSENGER LIFT WITH WIRRING(1.1)Supply,Installation, Testing & Commissioning of of 10 Passenger-cum-bed lift gearless with Machine room Capacity(1360 Kg),Elevator G+1 Floors with ACVVVF drive/Control with ARD 1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons in the Existing Lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. As per Direction of site Engineer In Charge. make:OTIS/Mitsubishi/Johnson/kone/Schindler/Thysenkrupp |
| 176 | Supply and fixing of Special Coper Plate (600*600*3.15mm with running coper flat 25*5mm long) Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per thevdirectuion of the side engineer incharge |
| 177 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required |
| 178 | Supply of 25 sq mm 3-1/2 core PVC Armoured cables ISI marked.(Make-Havells/Polycab/KEI/Equivalent) |
| 179 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
| 180 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 181 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years.. |
| 182 | Supplying and fixing 32 Amps rating, C series,10KA breaking capacity,2P, 220 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years.. |
| 183 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years. |
| 184 | S/F of 12x18x10 no 16/18 SWG sheet metal for main 63 amp panel board having 63 amp MCCB 1no., as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 185 | External worksS/F of Street light- 90W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 186 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat as per direction of Engg. in Charge. |
| 187 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 188 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 189 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 190 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 191 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-Polycab/KEI/Havells/Finolex/Gloster/RR Kabel |
| 192 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 32mm |
| 193 | PH WORK Internal P.H. WorkSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.20mm dia CPVC Pipe |
| 194 | 25mm dia CPVC Pipe |
| 195 | 32mm dia CPVC Pipe |
| 196 | 40mm diaC PVC Pipe |
| 197 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock (Jaquar/ Hindwar/ Johnson make) |
| 198 | 15mm dia CP two in one bib cock (Jaquar/ Hindwar/ Johnson make) |
| 199 | 15 mm dia CP S.B. Bib cock (Jaquar/ Hindwar/ Johnson make) |
| 200 | 15mm dia CP Long Body Bib cock (Jaquar/ Hindwar/ Johnson make) |
| 201 | 15mm dia CP Health faucet (Jaquar/ Hindwar/ Johnson make) |
| 202 | 25mm dia brass full way valve (Shakti make) |
| 203 | 32mm dia brass full way valve (Shakti make) |
| 204 | 40mm dia brass full way valve (Shakti make) |
| 205 | 15mm CP Extension piece |
| 206 | 125mm CP grating |
| 207 | 15mm size C.P. flange |
| 208 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge. 2000 liters capacity PVC water storage tank roof of 2rd floor (Sintex triple layer white colour) |
| 209 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 210 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 211 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 212 | 110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 213 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 214 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 215 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 216 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 217 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 218 | 110mm U-PVC plain tee(Ori Plast/Finolex/Supreme Make) |
| 219 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 220 | 110mm U-PVC soketOri Plast/Finolex/Supreme Make) |
| 221 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.E.W.C Single Piece Hindware/Parryware/Neycer make) |
| 222 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-chargeHalfpedestal basin(560x450)Hindware No.91049+91115 |
| 223 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 224 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24 x 18 x 10 sink |
| 225 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 226 | Towel ring |
| 227 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails. |
| 228 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type) |
| 229 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 230 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 231 | Supplying all materials, labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18 dia RCC MH cover |
| 232 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 233 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12cm size crusher broken hard granite Chips including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 234 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 30cmx30cm special printed series to be pre-approved by the Engineer-in-charge ) |
| 235 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 236 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge )Glazed tile 60cmx30cm Kajaria Elite plain/printed |
| 237 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liter's along with 3 noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in chargeAqua guard pure Chill 120 PSS UV |
| 238 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. D3:-4X0.75mx2.10m |
| 239 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge D3:-4X(0.75m+2.1m+2.1m) |
| 240 | External P.H. Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge110mm dia P.V.C. pipe (All round) |
| 241 | 160mm dia P.V.C. pipe (All round) |
| 242 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInside size 910mmx910mmx910mm |
| 243 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.80m dia x 2.60m deep soakway pit |
| 244 | 1 No 50 Users RCC Septic tankEarth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 245 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial lift. |
| 246 | Supplying all labor T&P & filling foundation and plinth with Sand materials well watered & rammed etc. all complete as per direction of EIC. |
| 247 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 12mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 248 | Supplying all materials,labour,T&P and providing 6mm thick cement plaster(14) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.(inside/outside) |
| 249 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge(inside/outside) |
| 250 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floorand roof slabs up to4.30M height. |
| 251 | R.C.C beams, columns gider and bressmber etc |
| 252 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 253 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 254 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 255 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 256 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. |
| 257 | Supplying all materials labor T&P filling extraviation material in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer in charge. |
| 258 | Construction of 30,000 lItter RCC U.G. SumpEarth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 259 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial lift. |
| 260 | Supplying all labor T&P & filling foundation and plinth with Sand well watered & rammed etc. all complete as per direction of EIC. |
| 261 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 262 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 263 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 264 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-chargeRCC floor, roof slab chhaja up to 4.430 m height |
| 265 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 266 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 267 | Rain Water Harvesting SystemSupplying all materials, labour, T&P and fitting and fixing U-PVC, SWR soil waste ventilating pipes and fitting of the following outside diameter conforming to 13592/1992 to walls with nails bobbins and wooden plugs or laying in trenches including with supply of approved rubber lubricant by non-heat application method as per manufactures specification testing earth work in excavation in all kinds of soil and refilling of trenches all complete as per specification and direction of the Engineer in charge. 110mm U-PVC SWR Pipe |
| 268 | 110mm U-PVC Plain bend |
| 269 | 110mm U-PVC Plain tee |
| 270 | 110mm dia GI clamp |
| 271 | 125mm dia CP grating |
| 272 | Supplying all materials labor T&P and binding glazed stone ware pipes and aligning to requisite gradient inside the trench to jointing with tarred cascade and cement motor prop.(1:1 )encasing the pipe all around with CC(1:3:6) with washed gravel CC(1:4:8) with hard stone metal size 25mm to 50mm on bed on the trench lowering the pipe to bed on trenches in earth work in excavation trenches in all kinds of soil and refilling the same in 30mm layers watering ramming and removal of surplus earth disorient sewer line including use of T&P sight rails binding rods plug lights etc .all complete as per P.H .Specification. All round concrete encasing up to 1.50metre depth. 160mm dia P.V.C. |
| 273 | Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 274 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18 dia RCC MH cover |
| 275 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessoriesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 30mtr |
| 276 | 31 mtr to 40mtr |
| 277 | Drilling of 150mm dia bore31 mtr to above |
| 278 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200mm dia P.V.C casing pipes00 mtr to 30 mtrs |
| 279 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.200mm dia PVC (sch-80) pipe |
| 280 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 281 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH Rig |
| 282 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:Rocky terrain with boulder formation for 300m depth |
| 283 | Supplying all materials , labour T&P and providing consturction of plat form as per UNICEF specifcation etc.all completes as per direction of Engineer-in-Charge |
| 284 | Supplying all materials ,labour T&P and providing fitting and fixing India Mark-II hand pump with C I Cylender and connectiong roads with providing 24.00 mtr of 32 mm dia GI raiser pipe etc. all complete as per P.H Specification and direction of Engineer-in-Charge |
| 285 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 286 | DOL Control panel |
| 287 | 40mm dia steel short piece |
| 288 | Well cap |
| 289 | 50mm size CI bracket |
| 290 | 2.50sqmm flat cable |
| 291 | 20mm dia rigid UPVC pipes |
| 292 | Steel rope with cover |
| 293 | Labour charges for lowering including transportation |
| 294 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge32mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender