Tender For Repair/Maint Of Ht Installations And Other Connected Wks At Ahrr Under Ge (E/M) repair renovation Hosp Delhi Cantt-10
Tender Value
47 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
18 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Ht Installations And Other Connected Wks At Ahrr Under Ge (E/M) repair renovation Hosp Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation and testing of Numerical Transformer Protection Relay (must communciate over IEC61850) in HT 11 KV Control Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on faults Differential Protection, Buchholz, WTI, OTI, PRV, MOG, over-current and earth-fault in any of the three phases, Transient earth fault, phase discontinuity,Trip circuit supervision relay, DC supervision relay with 5% pick up for OC and 5% for EF. The relay shall also have the following features as minimum; (i) Selectable CT input current 1A or 5A, (ii) Disturbance recording upto 300 cycles, (iii) 500 event record with time stamping,(iv) Analog input from 4 CT and 3 PT.(v) 10 DI (Digital input) & 6 DO (Digital output), (vi) Communicable on IEC61850 protocol, Data retrieval through front USB port incl reqd lifetime licensed software for data retrieval,(vii) Inrush protection,(viii) Self monitoring,(ix) Self supervision function. The relay shall be fully integrated with the feeder, internally capturing feeder statuses Breaker On, Off, Spring Chrgd, Test, Service, AC-Fail, DC supervision relay, Trip circuit healthy relay, local remote, Line-Current, Transformer differential, Buchholz, WTI, OTI, PRV, MOG, PT fuse failure.The relay shall be fixed on new 2mm CRCA sheet of matching existing control panel colour and suitable size covering all blank space formed by removing old mechanical type IDMT relay complete including associated wiring and integration with existing HT control panel, taking out old unsv relay complete all as specified and directed. \\"Make : ABB/Schneider/Siemens |
| 2 | M & L for necessary software/hardware for digital mapping of HT UG power cable routes with GPRS (Ground penetration Radar Survey) for locate and identify all existing underground cables in depth 2.5 mtr to 3.0 mtr, in width 5mtr including dimensional details of other utilities.joints, turnings/ diversions or specified if any by Engr-in-charge along with submitting 03 sets of hard copy drawing and soft copy duly indicating cable specification & lengths from and to bldgs / substations to which they are connected and indicating cable route indicators complete all as specified and directed by Engr-in-charge. Note : (i) The contractor will submit, explain and demonstrate technology / methodology being adapted for digital mapping on known route, submit the drawing and obtain prior approval from GE before proceeding with execution of this item. (ii) All necessary T&P, manpower, consumables required for execution of this item shall be arranged by the contractor. |
| 3 | M&L for route and depth tracing of HT UG power cable aluminium conductor cables, 11000 volts grade any core and size already laid complete cable lengths more than 100 mtr but not exceeding 1000 mtr including necessary tools, plants and machinary complete all as specified and directed by Engr-in-charge.Note : Applicable for item No 2 to 3 1. The UG cables are laid underground or on wall/roof and drawn through GI pipes/ ducts trenches etc. Therefore the contractor shall obtain permission of AGE / JE and user unit (whenever necessary) before tracing of cables.2. The contractor shall arrange necessary tools and technicians / labour for disconnecting cable end terminals if required and the cost of the same is deemed to included in the rate quoted.3. Since the work is executed on existing laid cable site for working may be available on rectricted hours, hence the contractor shall make his own arrangement and execute accordingly.4. The vender shall maintain a register of records as directed by Engr-in-charge for cable traced. Please Enable Macros to View BoQ information |
| 4 | M&L for route and depth tracing of HT UG power cable aluminium conductor cables, 11000 volts grade any core and size already laid complete cable lengths more than 100 mtr but not exceeding 1000 mtr including necessary tools, plants and machinary complete all as specified and directed by Engr-in-charge.Note : Applicable for item No 2 to 3 1. The UG cables are laid underground or on wall/roof and drawn through GI pipes/ ducts trenches etc. Therefore the contractor shall obtain permission of AGE / JE and user unit (whenever necessary) before tracing of cables.2. The contractor shall arrange necessary tools and technicians / labour for disconnecting cable end terminals if required and the cost of the same is deemed to included in the rate quoted.3. Since the work is executed on existing laid cable site for working may be available on rectricted hours, hence the contractor shall make his own arrangement and execute accordingly.4. The vender shall maintain a register of records as directed by Engr-in-charge for cable traced. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender