Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56947655

Tender For Repair And Maintenance Of Summer Appliances And Connected Items Of Various Units Near Kirby Place Area Under Ge(U) P&M, Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
38 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
18 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Summer Appliances And Connected Items Of Various Units Near Kirby Place Area Under Ge(U) P&M, Delhi Cantt-10

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF SUMMER APPLIANCES AND CONNECTED ITEMS OF VARIOUS UNITS NEAR KIRBY PLACE AREA UNDER GE(U) P&M, DELHI CANTT-10
Sl. No. Item Description
1Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keeping the AC unit in satisfactory working condition after necessary servicing as required and refixing the same in existing position complete all as specified and as directed .
2All as per srl item No 1.00 here-in-before but window type AC of capacity 1.5/ 2 TR complete all as specified and as directed.
3All as per srl item No 1.00 here-in-before but Tower type AC of any capacity complete all as specified and as directed.
4Material & Labour for changing mode of any type of AC from heating mode to cooling mode or vice-versa complete all as specified and as directed.
5Material & Labour for rectifying electrical wiring fault of any capacity type AC and make them functional and also carry out the required repair complete all as specified and as directed.
6Notes for item No. 1.00 to 5.00 (i) Adequate resources and manpower shall be deployed by the contractor for attending day to day defect being an essential installation. (ii) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as and when asked complete all as specified and as directed.(iii) All complaint/repairs shall be attended/completed within 06 Hour failing which a recovery of Rs 500/- per day per complaint shall be made from contractor dues.
7Supply and fixing in replacement Running capacitor 36+6 MFD complete all as specified and as directed .
8Supply and fixing in replacement Running capacitor 45+5 MFD complete all as specified and as directed .
9Supply and fixing in replacement Running capacitor 50+6 MFD complete all as specified and as directed
10Supply and fixing in replacement Starting capacitor 80-100 MFD complete all as specified and as directed .
11Supply and fixing in replacement Starting capacitor 100-120 MFD complete all as specified and as directed .
12Supply and fixing in replacement Starting Relay 1622 complete all as specified and as directed .
13Supply and fixing in replacement Starting Relay 2000 complete all as specified and as directed .
14Supply and fixing in replacement Thermostat switch 2059/2064/205 complete all as specified and as directed .
15Supply and fixing in replacement Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic complete all as specified and as directed .(Make as per site requirement.)
16Supply and fixing in replacement Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic complete all as specified and as directed .(Make as per site requirement.)
17Supply and fixing in replacement wiring kit for window/split type AC of Capacity 1.5/2 TR complete all as specified and as directed . (Make as per site requirement.)
18Supply and fixing in replacement remote control of existing make including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as specified & as directed
19Taking down unserviceable reversible valve for split AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required different copper pipe with PCB and remote alteration/modification complete all as specified and directed. (Note :- (i)Supply & filling of refrigerant gas shall be measured and paid under relevant item.) (ii) Any alteration or modification including electronic component required in PCB and Remote to be paid under relevant items.
20ditto- all as per item No. 18 above but window type Air Conditioner of capacity 1.5 TR.
21ditto- all as per item No. 18 above but window type Air Conditioner of capacity 2 TR.
22ditto- all as per item No. 18 above but spilt type Air Conditioner of capacity 2 TR.
23Material & Labour for Carryout the repairing work in remote control of AC of any type and any capacity complete all as specified and directed .
24Material & Labour for Carryout the pressure test with nitrogen gas of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed.
25Taking down, repairing and re-fixing main printed circuit board (PCB) with electric accessories and sensors suitable for inverter type split type AC/ window type AC all weather mode of any capacity and model complete all as specified and directed.
26Supply and fixing in repair PCB, suitable for inverter type, split type AC/ window type AC all weather mode of any capacity and model complete all as specified and as directed.
27Taking down, repairing and re-fixing PCB, suitable for split type AC/ window type AC of any capacity and model complete all as specified and directed.
28Supply and fixing in repair PCB suitable for split type AC/ window type AC of any capacity and model complete all as specified and as directed.
29Supply and fixing in repairs plastic louvers for (Front panel) for Window AC 1.5/2 TR complete all as specified & as directed (Make as per Sample).
30Supply and fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all as specified & as directed. {Note:- (i) 15mm (5/8'') or 6mm (1/4'') and 12mm (1/2'') made one set(ii) Supply & filling of refrigerant gas shall be measured and paid under relevant item.}
31Supply and fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample).
32Supply and fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample).
33Disconnecting from mains and taking out existing unserviceable sealed compressor unit and S&F in replacement sealed compressor unit with latest refrigerant gas compatible, suitable for 1.5/1.8 TR window type AC/ Split AC of existing capacity and make complete including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc and commissioning complete all as specified & as directed.
34ditto- all as per item No. 32 above but suitable for 2.0 TR window /Split type AC.
35Supply and fixing in replacement of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
36Supply and fixing in replacement of Indoor air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed.
37Supply and fixing in replacement of copper wounded motor for outdoor of Split type AC of 1.5 TR & 2 TR capacity complete all as specified & as directed.
38Material & Labour for Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed.
39ditto- all as per item No. 37 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
40Material & Labour for Disconnecting the mains and taking out the unserviceable evaporator/cooling coil of window type AC of capacity 1.5 TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed.
41ditto- all as per item No. 39 above but Window type Air Conditioner Capacity 2 TR.
42Taking down unserviceable outdoor unit inverter type all weather mode of split type AC of any capacity complete all as specified and as directed .
43Supply and fixing 1.5/1.8 TR capacity split type Air Conditioner outdoor kit inverter type all weather mode with latest refrigerant gas compatible including condenser coil with protection fins, blower motor and its fan blade, chassis & base plate with outdoor covering without compressor, suction and discharge valve, capillary tube of expansion valve, contactor with PCB card, capacitors and copper pipes & PVC wires of suitable size for internal connection, etc. complete all as specified & as directed for existing Make - Voltas/LG/Hitachi/Blue Star/ O General.
44ditto- all as per item No. 42 above but spilt type Air Conditioner outdoor kit inverter type all weather mode of capacity 2 TR for existing Make - Voltas/LG/Hitachi/Blue Star/General.
45Taking down unserviceable indoor unit inverter type all weather mode of split type AC of capacity 1.5 TR / 2 TR with remote complete all as specified & as directed.
46Supply and fixing new indoor unit inverter type all weather mode with remote control and with latest refrigerant gas compatible complete set suitable for 1.5/1.8 TR capacity complete all as specified & as directed for existing Make - Voltas/LG/Hitachi/Blue Star/O General.
47ditto- all as per item No. 45 above but inverter type all weather mode spilt type Air Conditioner of capacity 2 TR complete all as specified & as directed for existing Make - Voltas/LG/Hitachi/Blue Star/O' General. (Note for item No. 42 to 45:- Outdoor and indoor unit of AC shall be compatible either with each other or existing units)
48Disconnecting from mains and taking out existing unserviceable sealed inverter DC compressor unit and supply & fixing in replacement sealed inverter DC compressor unit with latest refrigerant gas compatible, suitable for 1.5/1.8 TR window type AC/ Split AC of existing capacity and make complete including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc commissioning complete all as specified & as directed for existing Make - Voltas/LG/Hitachi/Blue Star.
49ditto- all as per item No. 47 above but spilt type Air Conditioner outdoor kit inverter type all weather mode of capacity 2 TR for existing Make - Voltas/LG/Hitachi/Blue Star.
50Taking down unserviceable indoor unit of inverter split type AC of capacity 1.5/1.8 TR and supply & fixing new inverter type indoor unit complete set suitable for 1.5/1.8 TR capacity with remote control complete all as specified & as directed.
51ditto- all as per item No. 49 above but indoor unit of inverter split type AC of capacity 2 TR with remote control complete all as specified & as directed.
52Supply and fixing in repairs 1.5/1.8 TR capacity inverter type split type Air Conditioner outdoor kit including condenser coil, blower motor, chassis, base plate , suction and discharge valve, contactor, capacitors and copper pipe, PVC wires, PCB compatible to indoor unit, of suitable size for internal connection, etc complete all as specified & as directed for existing Make - Voltas/LG/Hitachi/Blue Star/Indcool/Camipro. .
53ditto- all as per item No. 51 above but Outdoor unit of inverter split type AC of capacity 2 TR complete all as specified & as directed.
54Supply and fixing in replacement heavy duty copper pipe 12mm (1/2\\") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and as directed.
55ditto- all as per item No. 53 above but copper pipe 6mm (1/4\\") dia/ bore.
56ditto- all as per item No. 53 above but copper pipe 15mm (5/8\\") dia/ bore.
57ditto- all as per item No. 53 above but copper pipe 10mm (3/8\\") dia/ bore.
58Taking down unserviceable insulation for copper pipe, S&F new insulation for existing copper pipes suitable for Split AC of capacity from 1.5 to 4.0 TR complete all as specified & as directed.
59Taking down unserviceable PVC drain pipe and S&F new PVC drain pipe 25 mm dia for Split/ window AC complete all as specified & as directed.
60Material & Labour for complete topping up the refrigerant gas (R22) in split/window type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
61Material & Labour for complete topping up the refrigerant gas (R22) in split/window type 2.0 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
62Material & Labour for complete topping up the refrigerant gas (R32/ R410A) in split/window AC type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
63Material & Labour for complete topping up the refrigerant gas (R32/R410A) in split/window AC type 2.00 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
64Material & Labour for complete topping up the refrigerant gas (R22/R32/R410A) in tower AC type & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
65Taking down unsv contactor and supply and fixing new contactor single phase suitable for window/ Split AC 1.5 to 2.0 TR complete all as specified & as directed.
66Taking down unserviceable contactor and supply and fixing new contactor ( MNX 12/ MNX 18) suitable for tower AC up to 4.0 TR capacity complete all as specified & as directed.
67Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed.
68Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed .
69Supply and fixing in replacement UPVC piping of dia 25mm complete with fittings, supports and duly covered complete all as specified & as directed.
70Supply and fixing in replacement Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed.
71Dismantling and Refixing the Split AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with Outdoor Unit’s pipes and Connecting indoor and outdoor units with copper pipes and installation of drainage pipes and Fixing Outdoor unit on separately ODU stand, Temperature & gas pressure testing, gas charging, Carpentry work, Plumbing, masonry & white cementing complete all as specified & as directed. Note : Drain Pipe, Copper of required size, Refrigerant gas, Outdoor stand, power plug, MCB and Copper wire will be paid under relevant items.
72Supply and fixing in repairs 1.5 TR capacity window type AC kit including condenser coil & evaporator coil (copper), copper wounded blower motor, cooling coil, front grill blower motor, chassis, base plate, reverse valve, capacitors and copper pipes & PVC wires of suitable size for internal connection etc including taking down old one complete all as specified and as directed for existing Make - Voltas/Dakin/Commander/ Hitachi/Blue Star.
73ditto- all as per item No. 71 above but of 2 TR capacity window type AC complete all as specified & as directed.
74Material & Labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of adequate size with all fittings and casing capping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed.
75ditto- all as per item No. 73 above but sub main wiring with two runs of single core 4 Sqmm
76Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed.
77Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed.
78Supply and fixing in repair metal clad socket of 20 Amps complete all as specified & as directed.
79Supply and fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed.
80Supply and fixing in replacement wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, copper wounded, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed. Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS.
81Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing as required and installation in same location complete all as specified and as directed .
82Supply and fixing in replacement over load protector relay suitable for 40/80 Litres capacity water coolers complete all as specified and as directed .
83Supply and fixingin replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed .
84Supply and fixing in replacement condenser motor fan blade suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed .
85Supply and fixing in replacement PVC flexible drain Hose Pipe 40 mm complete all as specified and as directed .
86Supply and fixing in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed. (Suitable for Voltas/Sidwal/Blue Star make water coolers).
87Supply and fixing in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed .
88Supply and fixing in replacement PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Litre capacity water coolers including GI socket of same size complete all as specified and as directed .
89Supply and fixing in replacement Starting Capacitor 25 MFD complete all as specified and as directed .
90Supply and fixing in replacement running Capacitor 10 MFD complete all as specified and as directed .
91Supply and fixing in replacement Starting relay suitable for 40/80, 60/120, 150/150 Liter complete all as specified and as directed .
92Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Liter and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed.
93All as per item No.91 above but 1/32 HP Water cooler of Capacity 40/80 Litres.
94Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor with latest refrigerant gas compatible of approved make obtained from authorised dealers, commissioning and testing of Water Coolers of 40/80 Litres capacity complete all as specified and as directed.
95Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor with latest refrigerant gas compatible of approved make obtained from authorised dealers , commissioning and testing of Water Coolers of 60/120 Litres capacity complete all as specified and as directed.
96Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor with latest refrigerant gas compatible of approved make obtained from authorised dealers , commissioning and testing of Water Coolers of 150/150 Litres capacity complete all as specified and as directed.
97Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Litres complete all as specified & as directed.
98Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Litres complete all as specified & as directed.
99Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Litres, checking the leakages of gas and rectify the leakages by brazing or as other manner complete all as specified & as directed (Make :- As per Sample)
100Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed.
101Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed inverter compressor of approved make refrigerant gas R-22/134A, commissioning and testing of refrigerators of 165 to 210 Litres capacity complete all as specified and as directed.
102Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed inverter compressor of approved make including charging of refrigerant gas R-22/134A, commissioning and testing of refrigerators of 280 to 310 Litres capacity complete all as specified and as directed. Note for item No. 100 & 101 :- (i) The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
103Disconnecting from mains and taking down for servicing of Refrigerator of Capacity 165/180/195/250/310 and 330 Litres including detecting the leakage of gas and cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs etc. and keeping the Refrigerator unit in satisfactory working condition after necessary servicing as required complete all as specified and as directed .
104Supply and fixing refrigerant gas R-134A/R32/R410/R600 in Refrigerators/ Deep freezers/ Water coolers of any capacity, model and make complete all as specified and as directed .
105Material & Labour for detecting the leakage of gas of Refrigerators/ Deep freezers/ Water coolers at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
106Supply and fixing in replacement capillary tube of existing size including necessary brazing suitable for 165/300 litres capacity refrigerator complete all as specified & as directed (Make :- As per Sample).
107Supply and fixing in replacement overload protector relay suitable for 165/300/310 litres capacity refrigerator complete all as specified and as directed .
108Supply and fixing in replacement thermostat suitable for 165/300/310 litres capacity refrigerators all complete all as specified and as directed .
109Supply and fixing in replacement freezer door with spring of refrigerators of any capacity complete all as specified and as directed . (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
110Supply and fixing in replacement vegetable basket with glass suitable for 165/300/310 litres capacity refrigerators complete all as specified and as directed . (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
111Supply and fixing in replacement PVC defrost tray as per sample suitable for 165/300/310 litres capacity refrigerators complete all as specified and as directed . (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
112Supply and fixing in replacement door gasket for refrigerators of capacity up to 250 Litres complete all as specified and as directed (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
113Supply and fixing in replacement door gasket for refrigerators of capacity more than 250 Litres but up to 310 litres complete all as specified and as directed. (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
114Disconnecting from mains and taking down for servicing of Deep freezer of Capacity 165/180/195/310/330/450 and 500 Litres including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing as required complete all as specified and as directed.
115Supply and fixing in replacement starting relay 1/6 HP open with OLP complete all as specified and as directed .
116Supply and fixing in replacement starting relay for 1/8 HP open type with OLP complete all as specified and as directed .
117Supply and fixing in replacement over load protector relay suitable for up to 500 Litres capacity deep freezer complete all as specified and as directed .
118Supply and fixing in replacement running capacitor for up to 500 Litres capacity deep freezer complete all as specified and as directed .
119Supply and fixing in replacement thermostat suitable for up to 500 Litres capacity deep freezer complete all as specified and as directed .
120Supply and fixing in replacement starting capacitor for up to 500 Litres capacity deep freezer complete all as specified and as directed .
121Supply and fixing in replacement Axial Fan for deep freezers complete all as specified and as directed.
122Taking down defective compressor of deep freezer of capacity Upto 300 Litres and any make and supplying and fixing sealed unit inverter compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capillary and testing complete all as specified and directed .
123All as per item No 121 above but of capacity above 300 Litres but up to 500 Litres deep freezer compressors.
124Material & Labour for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning as specified and re-fixing to existing place after servicing work complete all as specified and directed.
125Supply and fixing in replacement wood wool pad of suitable size for 24” sweep desert cooler, 01 Set comprising of 3 Nos of pads approximate weight 800-900 Gms as per sample complete all as specified & as directed.
126Supply and fixing in replacement submersible pump motor 230 Volts, single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified and as directed .
127Supply and fixing in replacement front grill for desert cooler of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp complete all as specified and as directed .
128Supply and fixing in replacement running capacitor of 4 MFD capacity for water cooler complete all as specified and as directed .
129Supply and fixing in replacement running capacitor of 6 MFD capacity for water cooler complete all as specified and as directed .
130Supply and fixing in replacement wire mesh for desert cooler pad (Set of Three) including taking down old one complete all as specified and as directed .
131Supply and fixing in replacement PVC pipe for connecting pump and water distributor of size 15 mm dia including PVC elbows complete all as specified and as directed .
132Supply and fixing in replacement PVC elbow for desert cooler of suitable size complete all as specified and as directed .
133Supply and fixing in replacement PVC 4 Way distribution cross for desert cooler complete all as specified and as directed .
134Supply and fixing in repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and as directed.
135Supply and fixing Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and as directed.
136Supply and fixing in repairs of flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5 Sqmm with permanently joined top of 15 Amps complete all as specified and as directed. Note :- (Length of wire about 1.5 meter)
137Supply and fixing in repairs desert coolers fan blade of 18\\" (inch) sweep make out of Aluminium complete all as specified and as directed .
138Supply and fixing in repairs switch piano flush type single pole one way 5Amp 230 V for desert cooler complete all as specified and as directed .
139Supply and fixing in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed.
140Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers i.e. side panel, bracket, body & desert cooler stand with two coats of synthetic enamelled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “GE (U) P&M (MES)” letter size of 50mm height at stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as specified & as directed.
141Supply and fixing in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) of sheet 22 Gauge and with side panels (03 Nos) fabricated out of 24 SWG PGI Sheet along with PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e., side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with \\"GE (U) P&M (MES)\\" letter size of 50mm height in stencil in black/white complete all as specified & as directed.
142Material & Labour for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed.
143Supply and fixing in replacement of drain tray for outdoor unit of split type AC of 1.5/2 TR capacity all as specified and as directed.
144Supply and fixing in replacement of PVC drain tray for window type AC of 1.5/2 TR capacity all as specified and as directed.
145Taking down unserviceable coil of indoor unit inverter type all weather mode of split type AC of any capacity 1.5/2 TR and supply & fixing new copper coil complete all as specified and as directed .
146Taking down unserviceable coil of indoor unit inverter type split type AC of any capacity 1.5/2 TR and supply & fixing new copper coil completecomplete all as specified and as directed .
147Supply and fixing in repair 40/80 Litres capacity water cooler fully stainless steel body (Top lid, front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank (SS-304 food grade minimum 0.80mm thickness of stainless steel sheet), Chiller tank with PUF insulation (thickness not less than 0.6mm), including float ball valve of suitable sizes, as per manufacturer's design & specification with Non CFC Refrigerant (R-134a) complete without compressor having storage capacity of 40 liters and nominal cooling capacity of 80 liters per hour, insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray, Brass (CR plated) push type double faucet, motor and condenser standing base made by stainless steel, ISI Marked including taking down old one complete all as specified and as directed for existing Make --Sidwal /USHA/BLUE STAR/Voltas.etc.
148Supply and fixing in repair of frost free refrigerator double door, electric driven (single phase, 230V, 50 Hz, AC supply) of capacity not less than 308/310 Ltrs capacity suitable for non CFC refrigerant complete without compressor including taking down old one complete all as specified and as directed for existing. (Make-SAMSUNG, Latest Model of Whirlpool/ LG/Godrej)
149Supply and fixing in repair of frost free refrigerator sigle door, electric driven (single phase, 230V, 50 Hz, AC supply) of capacity not less than 185/205 Ltrs capacity suitable for non CFC refrigerant complete without compressor including taking down old one complete all as specified and as directed for existing. (Make-SAMSUNG, Latest Model of Whirlpool/ LG/Godrej)
150Supply and fixing in repair PCB, suitable for inverter type refrigerator of any capacity, type and model complete all as specified and as directed.
151Supply and fixing in repair 4 core 2.5 Sqmm copper conductor cable flexible, PVC insulated, round wire complete all as specified ands as directed.
152Supply and fixing in repair Desert Cooler powder coated body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith distribution switch, 5 Amp piano switch and tank of depth 11 inch, electric driven (single phase), 230V, 50 Hz, AC, fitted with submersible pump of suitable capacity, rotary switch (Step type Speed Regulator), three core flexible copper conductor wire upto 1 mtr with 5 Amp Plug Top, wood wool pad on three sides and three speed Exhaust motor of copper wounded, 450 mm sweep complete all as specified and directed, Make-Khaitan/ CG/ Indcool. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56947655
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38 Lakhs
LAST DATE 01-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Summer Appliances And Connected Items Of Various Units Near Kirby Place Area Under Ge(U) P&M, Delhi Cantt-10
Basic Detail
Tender No GE(U)/PM/D-39/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 11 Aug 2026
Submission Date 01 Sep 2026
Open Date 05 Sep 2026
Finance
Tender Value 38 Lakhs
Tender Fee 500
EMD 76000
Exemption Available
Document List
9ac043eb-bad1-44d0-9a61-7337ea3b0521.html
BOQ_878314.xls
sch39.pdf
Tender39.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

9ac043eb-bad1-44d0-9a61-7337ea3b0521.html

xls

BOQ_878314.xls

pdf

sch39.pdf

pdf

Tender39.pdf

pdf

Tendernotice_1 (7).pdf