Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #56947654

Tender For Special Repair To Conversion Of Lt O/H Line Into Ug Cable With Connected Accessories At 216 T/C At Bb Cantt, Srinagar.

Issued by Statutory Bodies & Commissions/Committees · srinagar, Jammu and Kashmir
Tender Value
43.67 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
7 days left
EMD
87400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Conversion Of Lt O/H Line Into Ug Cable With Connected Accessories At 216 T/C At Bb Cantt, Srinagar.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Aug-2026 Corrigendum for Revised BOQ BOQ 31-Aug-2026

BOQ

Name of Work:- SPECIAL REPAIR TO CONVERSION OF LT O/H LINE INTO UG CABLE WITH CONNECTED ACCESSORIES AT 216 T/C AT BB CANTT, SRINAGAR.
Sl. No. Item Description
1Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil, complete all as specified and directed.
2Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed.
3Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
4M&L for locally available river sand in trenches 15 cm below cable and 8cm above / around UG cable for cable protection, in duct under and above the cables including punning around cable, complete all as specified and directed.Note: - Punned thickness shall only be measured and paid.
5Supply and laying GI pipe 'light grade' 40 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends, complete all as specified and directed.
6Supply and laying GI pipe 'light grade' 50 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends, complete all as specified and directed.
7Supply and laying GI pipe 'light grade' 80 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends, complete all as specified and directed.
8Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise, complete all as specified and directed.
9Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 150 sq mm 3.5 core, complete all as specified and directed.
10Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 95 sq mm 3.5 core, complete all as specified and directed.
11Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 70 sq mm 3.5 core, complete all as specified and directed.
12Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 50 sq mm 3.5 core, complete all as specified and directed.
13Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 25 sq mm 4 core, complete all as specified and directed.
14Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 25 sq mm 2 core, complete all as specified and directed.
15Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 16 sq mm 2 core, complete all as specified and directed.
16Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 10 sq mm 2 core, complete all as specified and directed.
17Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 6 sq mm 2 core, complete all as specified and directed.
18M & L for Copper busbar, weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 450 Amp capacity, 415 volt colour code with neutral including 250 Amp MCCB three phase and netural with encloser including indication lamp, angle iron leg and PCC foundation, complete all as specified and directed.
19M & L for Copper busbar, weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 150 Amp capacity, 415 volt colour code with neutral including 100 Amp MCCB three phase and netural with encloser including indication lamp, Angle iron leg and PCC foundation, complete all as specified and directed.
20Material and labour for road cutting of minimum sizes 30cm x 30cm for laying cables etc and making good the disturbed surface to match existing surface using plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate), complete all as specified and as derected.
21Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 32x6mm size GI strip as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and directed.
22Supply, installation, testing and commissioning inreplacement of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 600 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), including accomodating the following control gears and accessories:-
23(a) MCCB 400 Amps 4 pole ,36 KA 415 Volts (Incomer ) -01 No(b) SPN 63 Amps, 25 KA 240 Volts (outgoing ) -04Nos(c) MCCB 200 Amps 4 pole ,35 KA 415 Volts (outgoing ) -04 Nos(d) Copper Bus bar of capacity 650 Amps 3phase and neutral -1 set.(e) Digital type voltmeer 0-500 volts.(f) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No(g) Indicating LED lamps R,Y& B -01 set
24Supply, installation, testing and commissioning in replacement of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 350 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), including accomodating the following control gears and accessories:-
25(a) MCCB 200 Amps 4 pole ,36 KA 415 Volts (Incomer ) -01 No(b) MCCB 160 Amps 4 pole ,25 KA 415 Volts (Outgoing) -02 Nos(c) MCCB 100 Amps 4 pole ,25 KA 415 Volts (Outgoing) -01 No(d) SPN 63 Amps, 25 KA 240 Volts (outgoing ) -04 Nos(e) copper Bus bar of capacity 350 Amps 3phase and neutral -1 set.(f) Digital type voltmeer 0-500 volts.(g) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No(h) Indicating LED lamps R,Y& B -01 set
26Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 320 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), including accomodating the following control gears and accessories:-
27(a) MCCB 200 Amps 4 pole ,36 KA 415 Volts (Incomer ) -01 Nos(b) MCCB 100 Amps 4 pole ,25 KA 415 Volts (Outgoing) -03 Nos(c) SPN 63 Amps, 25 KA 240 Volts (outgoing ) -04Nos(d) copper Bus bar of capacity 320 Amps 3phase and neutral -1 set.(e) Digital type voltmeer 0-500 volts.(f) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No
28Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 450 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), including accomodating the following control gears and accessories:-
29(a) MCCB 250 Amps 4 pole ,36 KA 415 Volts (Incomer ) -01 No(b) MCCB 200 Amps 4 pole ,36 KA 415 Volts (Outgoing) -03 Nos(c) copper Bus bar of capacity 450 Amps 3 phase and neutral -1 set.(d) Digital type voltmeer 0-500 volts.(e) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No
30Supply and Erecting in vertical position steel tubular swaged pole type 410 SP-31 (9 metre long) with 300mmx300mm x6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enamelled paint up to 1.5M from ground level/coping, complete all as specified and directed.Note:- Earthwork and concrete shall be measured and paid saparatly under respective items.
31M&L for painting of existing steel tubular pole upto 09 mtrs length including clamp and bracket with two coats of aluminium paint after preparation of old painted surface and providing 03 no. alternate strip of 30 cm wide with black and white super quality enamel paint above embeded level and writing pole no. with 02 inch wide letter, complete all as specified and directed.
32Supply & fixing Thermo plastic street light sintex box of size 280 X 170 X 120 mm fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box, complete all as specified and directed.
33Supply & Fixing Automatic street light switch using NATURE SWITCH for automatic switching of street Lights based on LUX level of Natural Light. The sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/ wall mountable enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54 degree of ingress. The contactor, MCB and Circuit wiring should suitable enough to take load of 3 KW MCB (single-pole) Rating :32 Amps 3 Nos., complete all as specified and directed.
34Supply and fixing, cable route marker for LT cable duly engraved (LT 1.1 KV cable) on 150 mm dia MS round plate 10mm thik duly painted with yellow colour paint and fix on MS angle of 40mmx40mmx5mm with nuts and bolts and embedded in PCC (1:2:4) concrete block of size 230mmx 230mmx 150mm, including necessary excavation & eathed work, complete as specified and directed.
35Supplying, fixing, jointing and testing LT Service cable PVC insulated, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 10 Sqmm x 2 Core, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down old service cable, complete all as specified and directed.
36Supply and laying HDPE DWC Pipe outer dia 90/76 mm. for protection and covering the XLPE cable, complete all as specified and directed.
37Supply and fixing of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including taking down old lights & thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
38Supplying and fixing of flexible type round PVC bedded with PVC insulated and sheathed with multi FRLS cable of 1100 volt grade with multistranded copper conductor wire of size 1.5 Sq.mm 3 core type (Nominal area) ISI Marked, complete all as specified and as directed.
39Supply and fixing of rigid non metalic PVC conduit of size 15/20 mm bore heavy duty with all fitting laid in trenches/ wall including providing clamping arrangment for holding of pipe on wall in proper size of clamps, nut bolt ,and washer etc., complete all as specified.and directed
40Dismaintling old PCC/ tubular Pole from site with complete finishing existing surface, complete all as specified and directed
41Dismantling existing cross arms of any capacity/size of MS channel or angle sections etc., complete all as specified and directed.
42Dismantling existing insulators of any type and any size from pole including pins, complete all as specified and directed.
43Dismantling stay assembly of any type embedded in cement concrete etc., complete all as specified and directed.
44Dismantling and taking down the existing LT over head ACSR or AAC conductor of any description, complete all as specified and directed.
45Notes :-An amount of Rs 67,300.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56947654
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.67 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Conversion Of Lt O/H Line Into Ug Cable With Connected Accessories At 216 T/C At Bb Cantt, Srinagar.
Basic Detail
Tender No 864/WS-78(T)/2026-27
Bidding Type Tender
Location
City srinagar
State Jammu and Kashmir
Key Dates
Publish Date 20 Aug 2026
Submission Date 31 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 43.67 Lakhs
Tender Fee 500
EMD 87400
Exemption Available
Document List
BOQ_878145.xls
fce1f3e5-decc-4a70-8d6f-d73ca40c4d12.html
Tender78_merged.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_878145.xls

html

fce1f3e5-decc-4a70-8d6f-d73ca40c4d12.html

pdf

Tender78_merged.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders