Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #56947649

Tender For Repair Maintenance Of Unsv Vcb Rmu Transformer Ht Cable Ht Bus Bar And Other Connected Items At Af Stn Patiala Under Ge Af Ambala

Issued by Statutory Bodies & Commissions/Committees · Ambala, Haryana
Tender Value
20 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
14 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance Of Unsv Vcb Rmu Transformer Ht Cable Ht Bus Bar And Other Connected Items At Af Stn Patiala Under Ge Af Ambala

BOQ

Name of Work:- REPAIR MAINTENANCE OF UNSV VCB RMU TRANSFORMER HT CABLE HT BUS BAR AND OTHER CONNECTED ITEMS AT AF STN PATIALA UNDER GE AF AMBALA
Sl. No. Item Description
1Excavation in trenches for foundation n.exc 1.5 meter wide and n exc. 1.5 meter depth and not exc. 10 sqm on plan and getting out in soft/loose soil for laying cable of defferent size and errection of pole and assay etccomplete all as specified and directed.
2Returning, filling-in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
3Removing excavated material(soils) n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
4Material and labour for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.Note :- Thickness of sand cushioning after punning down i.e 18cm shall be measured for payment.
5Supply & laying un-reinforced precast concrete cable cover , Class HV type-1 flat, size 300mm x 180mm x 40mm, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of electric cable complete including taking out old bricks all as specified & directed.
6Material and labour for for boring/auguring suitable hole & insertion of 80 mm dia GI pipe including supply and inserting pipe not less than 600 mm below existing PCC/road/hard standing complete all as specified and directed.Note:- Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted.
7Taking out / down existing (serviceable / unserviceable) 11KV HT UG cable from trenches/duct/ HT poles, nominal cross sectional area from 95 sqmm to 120 Sqmm including disconnecting of cable and taking out cable covers/bricks) of any description complete all as specified & directed. Notes: (i) Excavation & Earth work shall be measured & paid separately.(ii) Serviceable cable covers/bricks will be kept aside for re-use and the unserviceable one shall be credited to contractor.
8Supply, laying, jointing, testing & commissioning heavy duty, HT 11 KV (E), XLPE insulated cable with aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked confirming to IS-7098 (Part-II), Size cross sectional area 95 Sqmm & 3 core laid as in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed.
9Supply, laying, jointing, testing & commissioning heavy duty, HT 11 KV (E), XLPE insulated cable with aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked confirming to IS-7098 (Part-II), Size cross sectional area 120 Sqmm & 3 core laid as in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. Please Enable Macros to View BoQ information
10Supply, laying, jointing, testing & commissioning heavy duty, HT 11 KV (E), XLPE insulated cable with aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked confirming to IS-7098 (Part-II), Size cross sectional area 120 Sqmm & 3 core laid as in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56947649
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 01-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Maintenance Of Unsv Vcb Rmu Transformer Ht Cable Ht Bus Bar And Other Connected Items At Af Stn Patiala Under Ge Af Ambala
Basic Detail
Tender No CWE/AF AMB/AMB-T21/2026-27
Bidding Type Tender
Location
City Ambala
State Haryana
Key Dates
Publish Date 11 Aug 2026
Submission Date 01 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
425a8226-55b0-4278-be13-c9ce8356b349.html
BOQ_878297.xls
Tender21T.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

425a8226-55b0-4278-be13-c9ce8356b349.html

xls

BOQ_878297.xls

pdf

Tender21T.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders