Tender For Repair/ Re-Routing Mafi Cables For Construction Of Road At Af Stn Tezpur
Tender Value
20 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
3 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Re-Routing Mafi Cables For Construction Of Road At Af Stn Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth for taking out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed. |
| 2 | All as per item No 1.00 here in before but Excavation in trenches exc. 1.5 m and n. exe 3 m in depth, complete all as specified and as directed. |
| 3 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 4 | Removing excavated Materials (Soils) not exc. 50 m distance and depositing where directed at a level not exc. 1.50 m above the starting point, complete all as specified and as directed. |
| 5 | Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path/PCC/Duct etc, complete all as specified and as directed. |
| 6 | M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. |
| 7 | Supply & Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 35 sqmm 4 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed.Note:- The cable may be passed through duct /pipes across runway/PTT etc.all necessary arrangement for passinng cables across runway /PTT through pippes /ducts to be made without any extra charges to the Govt. |
| 8 | All as per Item No. 7 above, but Nominal Cross-Sectional Area 95 Sqmm 4 Core. |
| 9 | All as per Item No. 7 above, but Nominal Cross-Sectional Area 150 Sqmm 4 Core. |
| 10 | M&L Straight Through (Heat shrink) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor of Nominal Cross-Sectional area exc. 50 Sqmm but not exc. 150 Sqmm, 3½/4 Core and Testing, complete all as specified and as directed. |
| 11 | S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. |
| 12 | M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe, complete all as specified and directed by the Engr-in-Charge at site. |
| 13 | Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles, complete all as specified and as directed. |
| 14 | S&F Galvanised Iron Pipe 100mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 15 | Re-laying only old Brick in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 1 here-in-before shall be reused in this item), complete all as directed. |
| 16 | M&L for LT Cable fault detection and its rectification by using Cable fault locator machine, span length maximum 2km of cable size 50 to 150sqmm all as specified and and directed by Engr-in-Charge. Note:-1. Earth work and jointing kit will be measured and paid seperately. |
| 17 | M&L for relaying heavy duty LT under ground cable of any sizes and types in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surface, complete all as specified & directed. |
| 18 | Taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 50/95/150/120 /95Sq mm, 3 ½ &4core, complete all as specified and directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender