Tender For Installation Of Air Conditioning System At The Passage Area Of Ground Floor And First Floor Of The Punjab, Udyog Bhawan, Chandigarh

Issued by Government Departments · Chandigarh, Chandigarh
Tender Value
34.42 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
0 days left
EMD
68900
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Installation Of Air Conditioning System At The Passage Area Of Ground Floor And First Floor Of The Punjab, Udyog Bhawan, Chandigarh

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 19-Aug-2026 Corrigendum Date 25-Aug-2026

BOQ

Name of Work:- Installation of Air Conditioning System at the Passage Area of Ground Floor and First Floor of the Punjab, Udyog Bhawan, Chandigarh
Sl. No. Item Description
1PVC Insulated FR Copper Conductor cables:
2Supply and erection of PVC insulated FR single cover unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer in charge.
3Overall Size 2.5 Sq.mm (un-sheathed)
4Overall Size 4 Sq.mm (un-sheathed)
5Overall Size 6 Sq.mm (un-sheathed)
6Overall Size 10 Sq.mm (un-sheathed)
7Supply and erection of PVC insulated PVC sheathed FR (3Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
8Overall size 2.5 Sq.mm (50/0.25mm), core
9Overall size 4.0 Sq.mm (56/0.3mm), core
10Overall size 6.0 Sq.mm (84/0.3mm), core
11PVC, HDPE Pipes and PVC Flexible Pipes:
12Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
13Heavy Guage PVC Conduit pipe 25mm dia (on surface)
14Heavy Guage PVC Conduit pipe 32mm dia (on surface)
15Copper Earthing (Upto 8 metre in length):
16Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
17Earthing with 20mm x 3mm copper tape (upto 8 metre in length)
18Copper Earthing Strip (As additional length):
19Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
20Additional length 20mm x 3mm thick copper tape
21Miniature Circuit Breakers:
22Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
23MCB Single Pole 6-32Amp (10kA, Curve-C)
24MCB Double Pole 40Amp (10kA, Curve-C)
25PVC Channel (uPVC Trunking):
26Supply and erection of PVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:-
27PVC Channel (uPVC Trunking) 100mm x 50mm
28SHEET METAL DOUBLE DOOR DISTRIBTUIOLN BOARD FOR MCB's/RCBO's/RCCB's
29Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&Nhorizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
30AC Plug and Socket SP&N with provision of One Single Pole MCB 20amp
31AC Plug and Socket TP&N with provision of One Triple Pole MCB 30/32amp
32SHEET METAL DOUBLE DOOR DISTRIBTUIOLN BOARD FOR MCB's/RCBO's/RCCB's
33Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
34TP&N Double Door Vertical DB's 8 way each (with provision of FP MCCB upto 125amp)
35MCCB's (Moulded Case Circuit Breaker)
36Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
37MCB Four Pole 63/80/100amp., 415 volts, > 25kA Fixed Magnetic and Adjustable Thermal Setting
38CABLE TRAY:
39Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
40Cable Tray Size 150mm x 50mm x 50mm (2mm thick)
41Supply and erection of heavy duty copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc., completely:
42Copper thimble cable core size 4-6 sq.mm
43Copper thimble cable core size 10-16 sq.mm
44Supply, Installation, Testing Commissioning of Tower split AC unit having capacity of 4 Ton with Vaccumising, Gas Charging complete with indoor and outdoor units, with all petty material complete in all respect as per Satisfaction of the Engineer-in-charge.
45Supply, Installation, Testing Commissioning of 2 Ton Cassete type split Air conditioning Unit with Vaccumising, Gas Charging, indoor and outdoor unit with all petty material complete in all respect as per Satisfaction of the Engineer-in-charge.
46Refrigerating Piping
47Interconnecting Refregerant pipe work with (19mm/13mm thick) closed cell elasttomeric nitrile rubber tubular insulation between each set of indoor & outdoor units with all petty matrial complete in all respect as per satisfaction of Engineer-in-Charge.
4819.1mm + 6.4mm (insulation :19mm)
4915.9mm O.D+ 6.4mm (insulation :19mm)
50S/E of MS Stand duly painted, fitted for 4 Ton outdoor unit with all petty material including nuts and bolts complete in all respect to the entire satisfaction of Engineer in charge.
51S/E of MS Stand duly painted, fitted for 2 Ton outdoor unit with all petty material including nuts and bolts complete in all respect to the entire satisfaction of Engineer in charge.
52Supply, installation, Testing, Commissioning of Copper Cable 4 core x 6 sq.mm complete in all respects as per satisfaction of Engineer in charge.
53Supply, installation, Testing, Commissioning of door Air curtain of size 3 feet 150 watt 960 RPM complete in all respects as per satisfaction of Engineer in charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56944092
AUTHORITY Government Departments
TENDER VALUE 34.42 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Department Of Industries And Commerce
Work Description Tender for Installation Of Air Conditioning System At The Passage Area Of Ground Floor And First Floor Of The Punjab, Udyog Bhawan, Chandigarh
Basic Detail
Tender No PSIEC/AC/UdyogBhawan
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 19 Aug 2026
Submission Date 25 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 34.42 Lakhs
Tender Fee 5900
EMD 68900
Exemption Not Available
Document List
90347994-c9bb-4727-b63e-07f918ca833f.html
BOQ_352769.xls
DNITAC.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

90347994-c9bb-4727-b63e-07f918ca833f.html

xls

BOQ_352769.xls

pdf

DNITAC.pdf

pdf

Tendernotice_1 (11).pdf