Tender For Drilling Of New Bore Wells, Flushing Of Existing Bore Wells, Repair And Reconditioning Of Pump Sets And Formation Of Flow Diversion Channel For The Following 1 No. Of Cwss In Theni District Under State Disaster Response Fund. (2026-27)
Tender Overview
Project Description
Tender for Drilling Of New Bore Wells, Flushing Of Existing Bore Wells, Repair And Reconditioning Of Pump Sets And Formation Of Flow Diversion Channel For The Following 1 No. Of Cwss In Theni District Under State Disaster Response Fund. (2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | VADUGAPATTY AND 57 OTHER RURAL HABITATIONS IN THENI DISTRICT UNDER STATE DROUGHT RELIEF FUND. |
| 2 | Add GST @ 18% Schedule A Name of the Work : Drilling of new bore wells, flushing of Existing Bore wells, Repair and reconditioning of pump sets and Formation of flow diversion channel for the following 1 no. of CWSS in Theni District Under State Disaster Response Fund. (2026-27) Sl.No Description of work Basic Amount (In Rupees) GST 18 % (In Rupees) Amount In Rupees |
| 3 | Vadugapatty CWSS Total 1552844.34 279511.98 1832356.32 Schedule A Name of the Work : Drilling of new bore wells, flushing of Existing Bore wells, Repair and reconditioning of pump sets and Formation of flow diversion channel for the following 1 no. of CWSS in Theni District Under State Disaster Response Fund. (2026-27) Sl.No DESCRIPTION QTY Specifications unit Rate in Rs. Amount in Rupees In figures In words Vadugapatty CWSS Drilling of New Borewells No Of Borewells |
| 4 | Drilling of 6\\" dia (150mm ) Vertical bores in over burden area to any required depth as desired by TWAD Board Officials including labour charges for inserting casing Pipes assembing in the drilled hole, including welding the joint, if necessory , grounding the casing pipes, etc., and including transport charges for the rig and supporting vehicles from one place to another as directed by TWAD Board Officers. |
| 5 | Drilling of 6\\" dia (150mm ) Vertical bores in Hard rock area to any required depth as desired by TWAD Board Officials including labour charges for inserting casing Pipes assembing in the drilled hole, including welding the joint, if necessory , grounding the casing pipes, etc., and including transport charges for the rig and supporting vehicles from one place to another as directed by TWAD Board Officers. |
| 6 | Upto 150m below Ground Level |
| 7 | From 151m upto 180 m |
| 8 | From 180m upto 210 m |
| 9 | Supply and delivery of following sizes of PVC CS Casing pipes specials confirming to IS specification at site of work as directed by TWAD Board officers. |
| 10 | Bore cap using M.S. Flat of size 1 cm x 3mm and M.S. sheet on top with boltingarrangements for securing the cap in position (Bore caps with M.S. Couplings need not be made)- 6” Casing Pipes |
| 11 | Labour Charges for inserting PVC Casingpipes assembly (with slots or without slots)in the drilled hole including jointing the pipeswith PVC Couplers with Cement paste etc.,complete, supply and packing the annularspace with pebbles of size and quality asapproved by the executive engineers ofTWAD Board Sub Total - II 396134.2 Pumpsets and Pumping main |
| 12 | Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150 mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screwsand CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % |
| 13 | 150 LPM X 150 M - 10.00 HP |
| 14 | Supply and delivery of Star-Delta starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/ 50HZ(+/-5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressedscale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature circuitrbraeker, Thermal overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventorand On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvcinsulated cable, power capacitor(thecoated vermin proof box, including the cost of capacitor is to be taken separately) |
| 15 | 10 HP LT Cables |
| 16 | PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER. |
| 17 | 4 Sq.mm Copper Cable |
| 18 | Laying the above cable as per IE rules from the between Transformer to rhe panel board |
| 19 | 4 Sq.mm Copper Cable |
| 20 | JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER(Item No.12.2-II /P.No.125/ SOR 2024-25) |
| 21 | 4 Sq.mm Copper Cable |
| 22 | Supply and delivey of pipes and specials including laying and jointing etc complete. |
| 23 | 50 mm GI Pipe |
| 24 | 50 mm GI Coupling |
| 25 | 50 mm GI Bend |
| 26 | 50 mm GI Flange set |
| 27 | 50 mm GI Tee |
| 28 | 50 mm GM Gate valve |
| 29 | 50 mm Non Return valve |
| 30 | 50 mm MS Clamp set |
| 31 | 50 mm GI Hex Nipple |
| 32 | 50 mm GI Flange set rubber |
| 33 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter,three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. |
| 34 | Above 5.00 HP to 10.00 HP Sub Total III 1108535.9 1308072.362 Desilting Of Intake Well |
| 35 | Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete. Sub Total IV 48174.24 Grand Total 1552844.34 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents