Tender For Supply Of Medium Voltage Cables (Lot-2) For Msb,Gds And Pfcc Unit Of Nrep
Tender Overview
Project Description
Tender for Supply Of Medium Voltage Cables (Lot-2) For Msb,Gds And Pfcc Unit Of Nrep , Supply Of Mv Cables As Specified In Mr Including Design, Engineering, Manufacturing, Inspection, Factory Acceptance Testing (Fat), Supply, Dispatch Of Medium Voltage Cables , Group 1 Power Cables: Stranded Aluminium Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 35 Sq. Mm (A2xfy) , 3C X 50 Sq. Mm (A2xfy) , 3C X 70 Sq. Mm (A2xfy) , 3C X 95 Sq. Mm (A2xfy) , 3C X 120 Sq. Mm (A2xfy) , 3C X 150 Sq. Mm (A2xfy) , 3C X 185 Sq. Mm (A2xfy) , 3C X 240 Sq. Mm (A2xfy) , 3C X 300 Sq. Mm (A2xfy) , 4C X 25 Sq. Mm (A2xfy) , 4C X 35 Sq. Mm (A2xfy) , 4C X 50 Sq. Mm (A2xfy) , 4C X 70 Sq. Mm (A2xfy) , 4C X 95 Sq. Mm (A2xfy) , 4C X 120 Sq. Mm (A2xfy) , 4C X 150 Sq. Mm (A2xfy) , 4C X 185 Sq. Mm (A2xfy) , 4C X 240 Sq. Mm (A2xfy) , 4C X 300 Sq. Mm (A2xfy) , 1C X 630 Sq. Mm (A2xway) , Group 2 Power Cables: (Fire Resitant) Fire Survival Cable, Stranded Copper, Epr Insulated Or Equivalent Material With Glass Mica Tape Insulation, Armoured, Inner And Outer Sheath As Per Relevant Iec Standards (A) The Insulation Shall Be Of Epr Or Equivalent Material With Glass Mica Tape Below Or Above Insulation. (B) Unless Otherwise Specified The Cables Shall Meet Requirement Of Circuit Integrity Test For A Minimum Period Of 3 Hours At Max. Temperature Of 950°C. , 4C X 2.5 Sq. Mm (2Xwy) -- For Mov , 12C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(12C)Nk (For Rxrg Contractor) , 19C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(19C)Nk (For Rxrg Contractor) , Group 3 Power & Control Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Tcoco(I/C)-1.5(3C)B : (For Rxrg Contractor) , 5C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(5C)K : (For Rxrg Contractor) , 10C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(10C)K : (For Rxrg Contractor) , 12C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(12C)K : (For Rxrg Contractor) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 4 Sq. Mm (2Xwy) , 3C X 6 Sq. Mm (2Xwy) , 3C X 10 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 25 Sq. Mm (2Xfy) , 3C X 35 Sq. Mm (2Xfy) , 3C X 50 Sq. Mm (2Xfy) , 3C X 70 Sq. Mm (2Xfy) , 3C X 95 Sq. Mm (2Xfy) , 3C X 120 Sq. Mm (2Xfy) , 3C X 150 Sq. Mm (2Xfy) , 3C X 240 Sq. Mm (2Xfy) , 3C X 300 Sq. Mm (2Xfy) , 1C X 630 Sq. Mm (2Xway) , 4C X 2.5 Sq. Mm (2Xwy) , 4C X 4 Sq. Mm (2Xwy) , 4C X 6 Sq. Mm (2Xwy) , 4C X 10 Sq. Mm (2Xwy) , 4C X 16 Sq. Mm (2Xwy) , 5C X 2.5 Sq. Mm (2Xwy) , 7C X 2.5 Sq. Mm (2Xwy) , 8C X 2.5 Sq. Mm (2Xwy) , 10C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ## , 14C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ##: E3-0.6/1.1-Mcoco(C)-2.5(12C)Nk - (For Rxrg Contractor) , 16C X 2.5 Sq. Mm ## , 19C X 2.5 Sq. Mm ## : E3-0.6/1.1-Mcoco(C)-2.5(19C)Nk - (For Rxrg Contractor) , Group 4 Lighting Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls : Red, Black & Green) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 4 Sq. Mm (2Xwy) , Supply Of Mv Cables As Specified In Mr Including Design, Engineering, Manufacturing, Inspection, Factory Acceptance Testing (Fat), Supply, Dispatch Of Medium Voltage Cables , Group 1 Power Cables: Stranded Aluminium Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 35 Sq. Mm (A2xfy) , 3C X 50 Sq. Mm (A2xfy) , 3C X 70 Sq. Mm (A2xfy) , 3C X 95 Sq. Mm (A2xfy) , 3C X 120 Sq. Mm (A2xfy) , 3C X 150 Sq. Mm (A2xfy) , 3C X 185 Sq. Mm (A2xfy) , 3C X 240 Sq. Mm (A2xfy) , 3C X 300 Sq. Mm (A2xfy) , 4C X 25 Sq. Mm (A2xfy) , 4C X 35 Sq. Mm (A2xfy) , 4C X 50 Sq. Mm (A2xfy) , 4C X 70 Sq. Mm (A2xfy) , 4C X 95 Sq. Mm (A2xfy) , 4C X 120 Sq. Mm (A2xfy) , 4C X 150 Sq. Mm (A2xfy) , 4C X 185 Sq. Mm (A2xfy) , 4C X 240 Sq. Mm (A2xfy) , 4C X 300 Sq. Mm (A2xfy) , 1C X 630 Sq. Mm (A2xway) , Group 2 Power Cables: (Fire Resitant) Fire Survival Cable, Stranded Copper, Epr Insulated Or Equivalent Material With Glass Mica Tape Insulation, Armoured, Inner And Outer Sheath As Per Relevant Iec Standards (A) The Insulation Shall Be Of Epr Or Equivalent Material With Glass Mica Tape Below Or Above Insulation. (B) Unless Otherwise Specified The Cables Shall Meet Requirement Of Circuit Integrity Test For A Minimum Period Of 3 Hours At Max. Temperature Of 950°C. , 4C X 2.5 Sq. Mm (2Xwy) -- For Mov , 12C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(12C)Nk (For Rxrg Contractor) , 19C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(19C)Nk (For Rxrg Contractor) , Group 3 Power & Control Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Tcoco(I/C)-1.5(3C)B : (For Rxrg Contractor) , 5C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(5C)K : (For Rxrg Contractor) , 10C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(10C)K : (For Rxrg Contractor) , 12C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(12C)K : (For Rxrg Contractor) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 4 Sq. Mm (2Xwy) , 3C X 6 Sq. Mm (2Xwy) , 3C X 10 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 25 Sq. Mm (2Xfy) , 3C X 35 Sq. Mm (2Xfy) , 3C X 50 Sq. Mm (2Xfy) , 3C X 70 Sq. Mm (2Xfy) , 3C X 95 Sq. Mm (2Xfy) , 3C X 120 Sq. Mm (2Xfy) , 3C X 150 Sq. Mm (2Xfy) , 3C X 240 Sq. Mm (2Xfy) , 3C X 300 Sq. Mm (2Xfy) , 1C X 630 Sq. Mm (2Xway) , 4C X 2.5 Sq. Mm (2Xwy) , 4C X 4 Sq. Mm (2Xwy) , 4C X 6 Sq. Mm (2Xwy) , 4C X 10 Sq. Mm (2Xwy) , 4C X 16 Sq. Mm (2Xwy) , 5C X 2.5 Sq. Mm (2Xwy) , 7C X 2.5 Sq. Mm (2Xwy) , 8C X 2.5 Sq. Mm (2Xwy) , 10C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ## , 14C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ##: E3-0.6/1.1-Mcoco(C)-2.5(12C)Nk - (For Rxrg Contractor) , 16C X 2.5 Sq. Mm ## , 19C X 2.5 Sq. Mm ## : E3-0.6/1.1-Mcoco(C)-2.5(19C)Nk - (For Rxrg Contractor) , Group 4 Lighting Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls : Red, Black & Green) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 4 Sq. Mm (2Xwy)
BOQ
| Sl. No. | Item Description |
| 1 | Supply of MV Cables as specified in MR including design, engineering, manufacturing, inspection, factory acceptance testing (FAT), supply, dispatch of Medium Voltage Cables |
| 2 | GROUP 1POWER CABLES:Stranded Aluminium conductor, extruded XLPE insulation, extruded PVC inner sheath, armoured, overall PVC outer sheath (FRLS) |
| 3 | 3C x 35 Sq. mm (A2XFY) |
| 4 | 3C x 50 Sq. mm (A2XFY) |
| 5 | 3C x 70 Sq. mm (A2XFY) |
| 6 | 3C x 95 Sq. mm (A2XFY) |
| 7 | 3C x 120 Sq. mm (A2XFY) |
| 8 | 3C x 150 Sq. mm (A2XFY) |
| 9 | 3C x 185 Sq. mm (A2XFY) |
| 10 | 3C x 240 Sq. mm (A2XFY) |
| 11 | 3C x 300 Sq. mm (A2XFY) |
| 12 | 4C x 25 Sq. mm (A2XFY) |
| 13 | 4C x 35 Sq. mm (A2XFY) |
| 14 | 4C x 50 Sq. mm (A2XFY) |
| 15 | 4C x 70 Sq. mm (A2XFY) |
| 16 | 4C x 95 Sq. mm (A2XFY) |
| 17 | 4C x 120 Sq. mm (A2XFY) |
| 18 | 4C x 150 Sq. mm (A2XFY) |
| 19 | 4C x 185 Sq. mm (A2XFY) |
| 20 | 4C x 240 Sq. mm (A2XFY) |
| 21 | 4C x 300 Sq. mm (A2XFY) |
| 22 | 1C x 630 Sq. mm (A2XWaY) |
| 23 | GROUP 2POWER CABLES: (FIRE RESITANT)Fire Survival Cable, Stranded Copper, EPR insulated or equivalent material with glass mica tape insulation, armoured, Inner and outer sheath as per relevant IEC standards(a) The insulation shall be of EPR or equivalent material with glass mica tape below or above insulation. (b) Unless otherwise specified the cables shall meet requirement of circuit integrity test for a minimum period of 3 hours at max. temperature of 950°C. |
| 24 | 4C x 2.5 Sq. mm (2XWY) -- For MOV |
| 25 | 12C x 2.5 mm2 : E4-0.6/1.1-MCXCX(C)-2.5(12C)NK (for RxRG CONTRACTOR) |
| 26 | 19C x 2.5 mm2 : E4-0.6/1.1-MCXCX(C)-2.5(19C)NK (for RxRG CONTRACTOR) |
| 27 | GROUP 3POWER & CONTROL CABLES:Stranded Copper conductor, extruded XLPE insulation, extruded PVC inner sheath, armoured, overall PVC outer sheath (FRLS) |
| 28 | 3C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-TCOCO(I/C)-1.5(3C)B : (for RxRG CONTRACTOR) |
| 29 | 5C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-MCOCO(I/C)-1.5(5C)K : (for RxRG CONTRACTOR) |
| 30 | 10C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-MCOCO(I/C)-1.5(10C)K : (for RxRG CONTRACTOR) |
| 31 | 12C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-MCOCO(I/C)-1.5(12C)K : (for RxRG CONTRACTOR) |
| 32 | 3C x 2.5 Sq. mm (2XWY) |
| 33 | 3C x 4 Sq. mm (2XWY) |
| 34 | 3C x 6 Sq. mm (2XWY) |
| 35 | 3C x 10 Sq. mm (2XWY) |
| 36 | 3C x 16 Sq. mm (2XFY) |
| 37 | 3C x 25 Sq. mm (2XFY) |
| 38 | 3C x 35 Sq. mm (2XFY) |
| 39 | 3C x 50 Sq. mm (2XFY) |
| 40 | 3C x 70 Sq. mm (2XFY) |
| 41 | 3C x 95 Sq. mm (2XFY) |
| 42 | 3C x 120 Sq. mm (2XFY) |
| 43 | 3C x 150 Sq. mm (2XFY) |
| 44 | 3C x 240 Sq. mm (2XFY) |
| 45 | 3C x 300 Sq. mm (2XFY) |
| 46 | 1C x 630 Sq. mm (2XWaY) |
| 47 | 4C x 2.5 Sq. mm (2XWY) |
| 48 | 4C x 4 Sq. mm (2XWY) |
| 49 | 4C x 6 Sq. mm (2XWY) |
| 50 | 4C x 10 Sq. mm (2XWY) |
| 51 | 4C x 16 Sq. mm (2XWY) |
| 52 | 5C x 2.5 Sq. mm (2XWY) |
| 53 | 7C x 2.5 Sq. mm (2XWY) |
| 54 | 8C x 2.5 Sq. mm (2XWY) |
| 55 | 10C x 2.5 Sq. mm ## |
| 56 | 12C x 2.5 Sq. mm ## |
| 57 | 14C x 2.5 Sq. mm ## |
| 58 | 12C x 2.5 Sq. mm ##: E3-0.6/1.1-MCOCO(C)-2.5(12C)NK - (for RxRG CONTRACTOR) |
| 59 | 16C x 2.5 Sq. mm ## |
| 60 | 19C x 2.5 Sq. mm ## : E3-0.6/1.1-MCOCO(C)-2.5(19C)NK - (for RxRG CONTRACTOR) |
| 61 | GROUP 4LIGHTING CABLES:Stranded Copper conductor, extruded XLPE insulation, extruded PVC inner sheath, armoured, overall PVC outer sheath (FRLS : RED, BLACK & GREEN) |
| 62 | 3C x 2.5 Sq. mm (2XWY) |
| 63 | 3C x 16 Sq. mm (2XFY) |
| 64 | 3C x 4 Sq. mm (2XWY) |
| 65 | Supply of MV Cables as specified in MR including design, engineering, manufacturing, inspection, factory acceptance testing (FAT), supply, dispatch of Medium Voltage Cables |
| 66 | GROUP 1POWER CABLES:Stranded Aluminium conductor, extruded XLPE insulation, extruded PVC inner sheath, armoured, overall PVC outer sheath (FRLS) |
| 67 | 3C x 35 Sq. mm (A2XFY) |
| 68 | 3C x 50 Sq. mm (A2XFY) |
| 69 | 3C x 70 Sq. mm (A2XFY) |
| 70 | 3C x 95 Sq. mm (A2XFY) |
| 71 | 3C x 120 Sq. mm (A2XFY) |
| 72 | 3C x 150 Sq. mm (A2XFY) |
| 73 | 3C x 185 Sq. mm (A2XFY) |
| 74 | 3C x 240 Sq. mm (A2XFY) |
| 75 | 3C x 300 Sq. mm (A2XFY) |
| 76 | 4C x 25 Sq. mm (A2XFY) |
| 77 | 4C x 35 Sq. mm (A2XFY) |
| 78 | 4C x 50 Sq. mm (A2XFY) |
| 79 | 4C x 70 Sq. mm (A2XFY) |
| 80 | 4C x 95 Sq. mm (A2XFY) |
| 81 | 4C x 120 Sq. mm (A2XFY) |
| 82 | 4C x 150 Sq. mm (A2XFY) |
| 83 | 4C x 185 Sq. mm (A2XFY) |
| 84 | 4C x 240 Sq. mm (A2XFY) |
| 85 | 4C x 300 Sq. mm (A2XFY) |
| 86 | 1C x 630 Sq. mm (A2XWaY) |
| 87 | GROUP 2POWER CABLES: (FIRE RESITANT)Fire Survival Cable, Stranded Copper, EPR insulated or equivalent material with glass mica tape insulation, armoured, Inner and outer sheath as per relevant IEC standards(a) The insulation shall be of EPR or equivalent material with glass mica tape below or above insulation. (b) Unless otherwise specified the cables shall meet requirement of circuit integrity test for a minimum period of 3 hours at max. temperature of 950°C. |
| 88 | 4C x 2.5 Sq. mm (2XWY) -- For MOV |
| 89 | 12C x 2.5 mm2 : E4-0.6/1.1-MCXCX(C)-2.5(12C)NK (for RxRG CONTRACTOR) |
| 90 | 19C x 2.5 mm2 : E4-0.6/1.1-MCXCX(C)-2.5(19C)NK (for RxRG CONTRACTOR) |
| 91 | GROUP 3POWER & CONTROL CABLES:Stranded Copper conductor, extruded XLPE insulation, extruded PVC inner sheath, armoured, overall PVC outer sheath (FRLS) |
| 92 | 3C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-TCOCO(I/C)-1.5(3C)B : (for RxRG CONTRACTOR) |
| 93 | 5C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-MCOCO(I/C)-1.5(5C)K : (for RxRG CONTRACTOR) |
| 94 | 10C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-MCOCO(I/C)-1.5(10C)K : (for RxRG CONTRACTOR) |
| 95 | 12C x 1.5 Sq. mm (2XWY) : E3-0.6/1.1-MCOCO(I/C)-1.5(12C)K : (for RxRG CONTRACTOR) |
| 96 | 3C x 2.5 Sq. mm (2XWY) |
| 97 | 3C x 4 Sq. mm (2XWY) |
| 98 | 3C x 6 Sq. mm (2XWY) |
| 99 | 3C x 10 Sq. mm (2XWY) |
| 100 | 3C x 16 Sq. mm (2XFY) |
| 101 | 3C x 25 Sq. mm (2XFY) |
| 102 | 3C x 35 Sq. mm (2XFY) |
| 103 | 3C x 50 Sq. mm (2XFY) |
| 104 | 3C x 70 Sq. mm (2XFY) |
| 105 | 3C x 95 Sq. mm (2XFY) |
| 106 | 3C x 120 Sq. mm (2XFY) |
| 107 | 3C x 150 Sq. mm (2XFY) |
| 108 | 3C x 240 Sq. mm (2XFY) |
| 109 | 3C x 300 Sq. mm (2XFY) |
| 110 | 1C x 630 Sq. mm (2XWaY) |
| 111 | 4C x 2.5 Sq. mm (2XWY) |
| 112 | 4C x 4 Sq. mm (2XWY) |
| 113 | 4C x 6 Sq. mm (2XWY) |
| 114 | 4C x 10 Sq. mm (2XWY) |
| 115 | 4C x 16 Sq. mm (2XWY) |
| 116 | 5C x 2.5 Sq. mm (2XWY) |
| 117 | 7C x 2.5 Sq. mm (2XWY) |
| 118 | 8C x 2.5 Sq. mm (2XWY) |
| 119 | 10C x 2.5 Sq. mm ## |
| 120 | 12C x 2.5 Sq. mm ## |
| 121 | 14C x 2.5 Sq. mm ## |
| 122 | 12C x 2.5 Sq. mm ##: E3-0.6/1.1-MCOCO(C)-2.5(12C)NK - (for RxRG CONTRACTOR) |
| 123 | 16C x 2.5 Sq. mm ## |
| 124 | 19C x 2.5 Sq. mm ## : E3-0.6/1.1-MCOCO(C)-2.5(19C)NK - (for RxRG CONTRACTOR) |
| 125 | GROUP 4LIGHTING CABLES:Stranded Copper conductor, extruded XLPE insulation, extruded PVC inner sheath, armoured, overall PVC outer sheath (FRLS : RED, BLACK & GREEN) |
| 126 | 3C x 2.5 Sq. mm (2XWY) |
| 127 | 3C x 16 Sq. mm (2XFY) |
| 128 | 3C x 4 Sq. mm (2XWY) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender