Tender For Repair/Maint And Cleaning Of Drain & Sewage Line, Septic Tank, Soakwell, Cover Slab, Culvert At Technical And Residential Area Cqa (I) Raipur Unedr Ge(I) R&D Dehradun
Tender Value
25 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
10 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint And Cleaning Of Drain & Sewage Line, Septic Tank, Soakwell, Cover Slab, Culvert At Technical And Residential Area Cqa (I) Raipur Unedr Ge(I) R&D Dehradun
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Cleaning of septic tank up to 25 users by removing sludge in semi solid sate or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 2 | M&L for Cleaning of septic tank exc 25 users and not exc 50 users by removing sludge in semi solid sate or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 3 | M&L for Cleaning of septic tank exc 50 users and n.exc 100 users by removing sluge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 4 | M&L for Cleaning of septic tank exc 100 users and n.exc 200 users by removing sluge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 5 | M&L for Dewatering of soak well or sewage of any dia and depth manully or by using pumps and rremoval of sludge if any to a distance exc1.5km but not exc 2Km out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 6 | M&L for cleaning with suitable chemical of P/S trap of EWC/IWC etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 7 | M&L for cleaning of Nahani/floor trap of Bath/kitchen/urinal/ wash basin incluing Ist gully trap etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 8 | M&L for cleaning of Sewage pipe line from gully trap to ISt manhole an then upto the final drop into the septic tank an soak well /cess pool (except intermediate manholes ) by removing all blockage of any description in any situation in the system complete any ia of pipe an epth by rodding ,manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 9 | M&L for cleaning of manholes any type & size and any depth by removing of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5km but n.exc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 10 | S&F framed work such as guard bars, grills , hold fast, door frame etc and similar work confirming to Fe-410-0 or Fe-310-0 complete all as specified and directed. |
| 11 | M&L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 12 | Excavating in trenches,n.exc 1.5m wide and n.exc 1.5m in depth,for foundation,etc or for shafts, wells,cesspits,manholes, pier holes etc n.exc. 10sqm on plan and getting out in soft/loose soil soil complete all as specified and directed. |
| 13 | Removing of excavated material (Soil) to a distance exc 250m but not exceeding 500 mtr and depositing at a level n.exc 1.5 m above the starting points complete all as specified an directed. |
| 14 | Returing , filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm completed all as specified and directed. |
| 15 | Dismantling floor, heart wall tiling including cement and sand mortar bedding ( but not backing ) including rubbish off the premises complete all as specified and directed. |
| 16 | M&L for non- skid coloured creamic tiles (1st quality/ premium quality) 7 to 8 mm thick, ( square/ rectangular) area of each tiles exc 0.11 sqm but n exc 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in coloured or white cement to match the colour of tiles as in floor over 10 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 17 | M&L for glazed ceramic colourd tiles joint free of size 300x200x7 mm (1st quality/ premium quality) , in vertical surfaces such as riser of step, skirting, dado and piller, over and including rendering 10 mm thick platering as bed or bedding layer in CM (1:4) , set and jointed in neat cement slurry and pointed in white or colourd cement to match complete all as specified and directed |
| 18 | M&L PCC 1:3:6(Using 40mm graded crushed stone aggregate) as in Concrete bed to drain pipes ( bore of pipes is 200 mm) including packing under and completely surrounding pipes with concrete after they are laid and tested in complate all as specified and directed. |
| 19 | M&L PCC 1:3:6(Using 40mm graded crushed stone aggregate) as in Concrete bed to drain pipes ( bore of pipes is 150 mm) including packing under and completely surrounding pipes with concrete after they are laid and tested in complate all as specified and directed. |
| 20 | M&L salt glazed stoneware drain pipe, bore of pipe 200mm , laid and jointed complete with collers completed all as specified and directed. |
| 21 | M&L salt glazed stoneware drain pipe, bore of pipe 150mm , laid and jointed complete with collers completed all as specified and directed. |
| 22 | S&F bend and taper bends of any radius for SGSW drain pipe for 200mm dia pipe complete all as specified and directed. |
| 23 | S&F bend and taper bends of any radius for SGSW drain pipe for 150mm dia pipe complete all as specified and directed. |
| 24 | Demolition of stone/brick masonry built in cement mortar incl all quions, Arches, pillers etc complete all as specified and directed. |
| 25 | M&L for brick work with using sub class 'B' brick ,straight or curved on plan exc. 6 meter radius, built in CM(1:6) for wall but complete all as specified and directed. |
| 26 | Taking down cement plaster on brick or stone walls including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 27 | M&L for 15mm thick rendering in CM 1:4 on surfaces of wall finished surface fair & even without using extra cement complete all as specified and directed. |
| 28 | Repairs to plaster with cement mortar 1:4 of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 29 | S&F in repair 20 mm dia bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/2 0mm-210gms./25mm-455gms/ 40mm- 690 gms) complete all as spfd and directed. |
| 30 | S&F in repair 15mm size PVC connections internally threaded with PVC washer,PTMT nuts of length 450mm complete all as specified and directed. |
| 31 | S&F in repair PVC (SWR) pipes 110 mm bore, single socketed, in any length with rubber ring joints, fixed to walls, in trances, in floor complete all as specified and directed. |
| 32 | S&F PVC (SWR) bends any radius, with access door, for 110 mm bore of pipe complete all as specified and directed. |
| 33 | S&F in repair PVC (SWR) pipes 75 mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 34 | S&F PVC (SWR) bends any radius, with access door, for 75 mm bore of pipe complete all as specified and directed. |
| 35 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20 mm dia pipes complete all as specified and directed. |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 15mm dia pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing or Concealed work, i/c cutting chases and making good the wall etc. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 37 | M&L for Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipe etc and making good cutting not exc 10cm. complete all as specified and directed. |
| 38 | Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 39 | S&F in repair Waste coupling to WHB/ kitchen and laboratory sink of 32/40 mm dia complete all as directed by Engr in Charge, |
| 40 | S&F in repair PVC Waste pipe( streachable) to WHB/ kitchen sink of 32 mm dia complete all as directed by Engr in Charge, |
| 41 | S&F in repair GI Elbow/Tee/Socket/union of 15/20 mm dia to be fixed in any position and at any height complete all as directed by Engr in Charge. |
| 42 | Disconnecting & taking down existing water tank of capacity exc 250 liter and not exc.500 liter and removing from site complete and S&F rotational moulded polyethylene water storage tanks 500 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed. |
| 43 | S&F in repair vitreous china wash hand basin (flat back) of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, MS brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed. |
| 44 | S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed. |
| 45 | Demolition of cement concrete(unreinforced ) in ground floor and pavings n exe 15 cm thickness (below or above ground level ) complete all as specified and directed. |
| 46 | M&L for Plain cement concrete 1:5:10 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 47 | M&L for PCC 1:3:6, type C1 ( using 20 mm graded stone aggregate ) as in leveling course, coping, benching, flooring,surface channel / sub base drain finishing cement concrete surface incl forms / mould complete all as specified and directed. |
| 48 | M&L prepolished, machine pressed chequred cement concrete coloured tiles 30cm x 30cm x 25 mm thick, set , jointed and pointed in neat cement slurry with mixer of white cement and pigmenet as in floors/pavements/ paths laid over screed bed or bedding layer in cement mortar 1:4, 20 mm thick screed bed complete all as specified and directed. |
| 49 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 30cm deep and getting out of soft loose soil complete all as specified and directed. |
| 50 | M&L for hardcore of gauge not exceeding 63 mm of broken stone/boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 51 | M&L for 25 mm thick sand cushion layer for laying interlocking pavers complete all as specified and directed. |
| 52 | M&L for 80 mm thick precast PCC interlocking coloured paver rubber moulded block factory made of grade M-40 single layer monolithic high density manufactured by electro vibro hydraulically operated block making maching conforming to IS -15658- 2006 laid and jointed over sand cushion layer complete all as specified and directed. Note : Sand cusion shall be measured & paid separately |
| 53 | M&L for Preparing old/new plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed. |
| 54 | Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc., capacity of tank exc 500 & n exc 1000 litres including writing date of cleaning on the tank with suitable synthetic enamel paint etc complete all as specified and directed. |
| 55 | Cleaning and desilting of sewage line/open drain of any size including removal of rubbish mixed with earth, remove drain cover and relocate in postion after clean drain etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 56 | M&L for preparation of old/ newly plastered surfaces of wall/dome/ring/ column/beam etc of RCC over head water tank up to 50m height and applying two coats of weather proof exterior paint or apex (any colour) silicon based over a coat of water based suitable primering as a base course as per manufacturer's instructions including necessary scaffolding upto any height complete all as specified and directed by Engr- in Charge. |
| 57 | M&L for applying one coat of synthetic enamel paint on old painted steel surfaces of any description of RCC over head water tank railing and stair / ladder up to 50m height etc complete all as specified including preparation and complete removal of existing treatment complete all as specified and directed. |
| 58 | Demolition cement concrete (reinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 59 | M&L Providing cover slab of PCC 1:2:4 type B 1 using 20 mm graded aggregate and set in cement mortar 1:6 as in cover slab including placing in position complete all as spfd and directed ( Note : - reinforcement shall be measure and paid separtely under respective item of sch A). |
| 60 | M&L for TMT 10 mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, beam and Fdn, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips complete all as specified & directed. |
| 61 | M&L PCC 75 mm thick (1:3:6) type C-1 using 20 mm graded aggregate, plinth protection / sub base, surface channel/ sub base in drain finishing cement concrete surface incl forms/mould etc complete all as specified and directed.. |
| 62 | Dismentiling structural steel work in cludding doors, any type of gates complete all as specified and directed. |
| 63 | S&F in repair Vitreous China urinals, half stall type white urinal, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 64 | S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed. |
| 65 | S&F for collapisal steel gates, top hung, consisting of channel picket, pivoted flat bar, top and bottom runners, brass handles etc, icluding erection in position and securing runners with holdsfast and bracket complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender