Tender For Provision Of Exterior Emulsion For Building No P-19 (Mahesh) At Sma(R) Under Ge Fort Kochi
Tender Value
24 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
8 days left
EMD
48000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Exterior Emulsion For Building No P-19 (Mahesh) At Sma(R) Under Ge Fort Kochi
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. |
| 2 | Material and labour for rendering 8mm thick in cement mortar 1:4 using liquid WPC over 12mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & fair without using extra cement at any floor complete all as specified and as directed. Note: Water proofing compound shall be paid separately. |
| 3 | Supply only liquid water proofing compound, complete all as specified and as directed. |
| 4 | Taking down PVC (SWR) pipes (any size or pattern), including all fittings, complete all as specified and as directed. |
| 5 | Supply and fix 110mm bore PVC (SWR) pipes single socketed in any length with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls/ laid in floors complete all as specified and as directed. |
| 6 | Supply and fix 75mm bore PVC (SWR) pipes single socketed in any length with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls/ laid in floors complete all as specified and as directed. |
| 7 | Supply and fix 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal with accessible door, complete all as specified and as directed. |
| 8 | Supply and fix 110mm bore PVC (SWR) bends any radius with accessible door complete all as specified and as directed. |
| 9 | Supply and fix 75mm bore PVC (SWR) junction single, (double Y) equal or unequal with accessible door complete all as specified and as directed. |
| 10 | Supply and fix 75mm bore PVC (SWR) bends any radius, complete all as specified and as directed. |
| 11 | Supply and fixing CPVC pipes 25mm of pressure rating 10 Kgf/cm² fixed complete to walls, ceilings or in floors etc., any type of pipe including taking up or down steel tubing and connections, complete all as specified and as directed. |
| 12 | Supply and fix 110mm bore PVC (SWR) T bends any radius with accessible door complete all as specified and as directed. |
| 13 | Supply and fixing Un-plasticised PVC pipes 40mm of pressure rating 10 Kgf/cm2 fixed complete to walls, ceilings or in floors etc, any type of pipe including taking up or down steel tubing and connections, complete all as specified and as directed. |
| 14 | Supply and fixing in repairs 75mm PVC (SWR) floor trap, with CP grating including jointing with solvent cement, complete all as specified and as directed. |
| 15 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 16 | Material and labour for cement concrete, 1:5:10, type E2, using 40mm graded stone aggregate as in filling under sunken floors complete all as specified and as directed. |
| 17 | Material and labour for 40 mm thick PCC 1:2:4, type B1, using 20 mm graded stone aggregate, with water proofing liquid @0.2 ltr /bag of cement as padding concrete in Sunken floor finished even and smooth without using extra cement, complete all as specified and as directed. |
| 18 | Material and labour for applying two components acrylic polymer modified cementitious flexible water proof coating which shall be further mixed with water at site as recommended by the manufacturer. The coating shall be applied in two coats to form a total thickness of 1mm. The water proof coating shall be protected with plastering in cement mortar 1:4 using integral waterproofing compound to a minimum thickness of 20mm. The contractor shall give 5 years guarantee for water proofing of this area also. The work shall be got done through authorized applicator of the manufacturer, complete all as specified and as directed.Note: - (a) The rate is including the whole process with materials. |
| 19 | Material and labour for complete removal of existing treatment by brooming down or steel wire brushing, scrapping down moulds, moss efflorescent salts and greasy spots etc and filling the cracks properly using crack filler compound and finally washing with water jet. The surface should be completely dry. The contents Nitocote wall guard or equivalent shall be thoroughly stirred for at least 2 minutes using slow speed (300-400 RPM) drilling machine attached with a mixing paddle. Apply first coat of Nitocote wall guard or equivalent with a nylon brush or a felt roller to the primed substrate. Allow the surface to dry 5-6 hours and then apply second coat. work shall be done up to 8 storey height complete all as specified and as directed. Note: - Nito coat wall guard or equivalent shall be applied at theoretical application rate 3- 3.5 Sqm/ ltr for two coats. The rate shall include cost of all materials, machinery labour and scaffolding etc. |
| 20 | Chip and remove all damaged and de bonded concrete and plaster from the RCC column, beam, flights, landing, railing and slabs by manually or mechanically so as to expose the corroded reinforcement bars including the rent of tools, scaffolding complete up to 8th storey high and labour charges for dumping the debris within a radius of 100 meters complete all as specified and as directed. |
| 21 | Supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd) or Amandur, (Manufactured by GK Technocom) or equivalent over the corroded reinforcement bar wherever micro concreting is required and cleaning the same after application including the cost of all materials, rent of tools, brush etc complete up to 8th storey high complete all as specified and as directed. |
| 22 | Supply and application of Nitozinc Primer (Manufactured by M/s Fosroc Chemicals India Ltd) or equivalent over the exposed steel reinforcements after removing the rust scales from the exposed reinforcement rods in one square meter area including the cost of all materials rent of tools, cost of paint brush up to 8th storey high, complete all as specified and as directed. |
| 23 | Supply and application of Nitobond EP (Manufactured by M/s Fosroc Chemicals India Ltd) or equivalent epoxy bonding agent over the old concrete surface including the cost of all materials, rent of tools, scaffolding and cost of painting brushes etc up to 8th storey high, complete all as specified and as directed. |
| 24 | Providing additional reinforcement bars in place of more than 1/3 corroded reinforcement bars including the charges for cutting, bending, placing and fixing in position using Lok-Fix (Manufactured by M/s Fosroc Chemicals India Ltd) including the cost of all materials rent of all accessories and tools, scaffolding and supporting materials, labour charges including the cost of steel bars complete all as specified and as directed. |
| 25 | Supply and provisioning Renderoc RG non-shrink cementitious micro concrete (max 120 mm thick) (Manufactured by M/s Fosroc Chemicals India Ltd or equivalent ) to any thickness for beam and column. Fluid micro concrete shall be mixed with 6mm down coarse aggregate and specified quantity of water and mixed using a power operated slow speed stirrer and pouring inside the form work including the cost of all materials, rent for tools, and labour charges, water tight formwork etc. all as per manufacturer instructions complete all as specified and as directed. |
| 26 | Material and labour for complete removal of existing treatment and preparation of external wall surfaces by scrubbing using nylon/ jute/ wire brushes/ scrapper blades or by using sanding machines to remove shrubs , vegetation, roots etc, weeding out plants / bushes including roots from the chajjas, roof, ceiling & wall surface of entire building and applying weedicide, (Imazethapyr 10% SI or equivalent) around area of the roots and loosely adhered like dust, efflorescence etc. and washing the surface with pressure jet washers and surface allowed to dry, up to 4 storey height, complete all as specified and as directed. |
| 27 | `Ditto- all as per item No 26 here-in-above but work at 5th to 8th storey height. |
| 28 | `Ditto- all as per item No 26 here-in-above but work at 9th to 12th storey height. |
| 29 | Material and labour for treating holes, cracks etc. up to 5mm by making \\"V\\" groove using Patti blades and filling the cracks with ready to use crack fillers of approved make all as specified and allowed to dry, up to 4 storey height complete all as specified and as directed. |
| 30 | `Ditto- all as per item No 29 here-in-above but work at 5th to 8th storey height. |
| 31 | `Ditto- all as per item No 29 here-in-above but work at 9th to 12th storey height. |
| 32 | Material and labour for treating holes, cracks etc. more than 5mm up to 10mm, by making \\"V\\" groove using Patti blades and filling the cracks with cement and sand aggregate mixture developed with polymer modified mortar (PMM) with suitable polymers like Home shield crack fill paste, Home shield advance latex plus and home shield cement mi plus and allowed to dry, up to 4 storey height complete all as specified and as directed. |
| 33 | `Ditto- all as per item No 32 here-in-above but work at 5th to 8th storey height. |
| 34 | `Ditto- all as per item No 32 here-in-above but work at 9th to 12th storey height. |
| 35 | Material and labour for treating holes, cracks etc. more than 10mm and up to 40mm, and filling the cracks by using flexible, 2 pack, polysulphide sealant like Berger home shield joint seal GG/PG or equivalent and allowed to dry, up to 4 storey height complete all as specified and as directed. |
| 36 | `Ditto- all as per item No 35 here-in-above but work at 5th to 8th storey height. |
| 37 | `Ditto- all as per item No 35 here-in-above but work at 9th to 12th storey height. |
| 38 | Material and labour for acrylic wall care putty in 2 coats, not less than 1mm thick on external walls up to 4 storey height complete all as specified and as directed. |
| 39 | `Ditto- all as per item No 38 here-in-above but work at 5th to 8th storey height. |
| 40 | `Ditto- all as per item No 38 here-in-above but work at 9th to 12th storey height. |
| 41 | Material and labour for application of one coat of primer with sealant properties using “Seal-O-Prime” or “weather coat exterior primer\\" or equivalent complete and allowed to dry overnight to receive first coat of emulsion paint, up to 4 storey height complete all as specified and as directed. |
| 42 | `Ditto- all as per item No 41 here-in-above but work at 5th to 8th storey height. |
| 43 | `Ditto- all as per item No 41 here-in-above but work at 9th to 12th storey height. |
| 44 | Material and labour for applying first coat of Exterior emulsion paint on primed wall surfaces using rollers made from form or synthetic fibres to get a tint free surface up to 4th storey height and allowed to dry for at least 8 hours/ overnight to receive second coat of emulsion paint, complete all as specified and as directed. |
| 45 | `Ditto- all as per item No 44 here-in-above but work at 5th to 8th storey height. |
| 46 | `Ditto- all as per item No 44 here-in-above but work at 9th to 12th storey height. |
| 47 | Material and labour for applying second coat of Exterior emulsion paint on wall surfaces using rollers made from form or synthetic fibres to get a tint free surface up to 4th storey height complete all as specified and as directed. |
| 48 | `Ditto- all as per item No 47 here-in-above but work at 5th to 8th storey height. |
| 49 | `Ditto- all as per item No 47 here-in-above but work at 9th to 12th storey height. |
| 50 | Material and labour for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying a coat of synthetic enamel paint up to 12th storey complete all as specified and as directed. |
| 51 | Material and labour for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described applying with two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer complete all as specified and as directed. |
| 52 | Note: Rates quoted against Sl. No 1 to 25 are for any height up to twelve storeys and including necessary scaffolding etc. as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer