Tender For Repair/ Replacement Of Lt Ug Cable, Junction Box, Lt Panel And Other Connected Works For Maintenance Of External Electric Supply At Af Stn Thoise And Siachen Base C Under Ge (Af) Thoise
Tender Value
38 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
5 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
LADAKH → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Lt Ug Cable, Junction Box, Lt Panel And Other Connected Works For Maintenance Of External Electric Supply At Af Stn Thoise And Siachen Base C Under Ge (Af) Thoise
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge. |
| 2 | Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a Hard/Dense soil complete all as specified and directed by Enginer-in-Charge. |
| 3 | Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specifed and as directed by Engineer-in-Charge.Note:-Excavation and earth work to be measured and paid for separately |
| 5 | Reuse of old serviceablePCC Cable cover obtain from replacement of cables(Fixing only) complete all as specifed and as directed by Engineer-in-Charge. |
| 6 | Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specifed and as directed by Engineer-in-Charge.Note: Punned thickness shall be measured. |
| 7 | M&L for in repair / replacement XLPE insulated, screened, PVC bedded, armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specifed and as directed by Engineer-in-Charge. |
| 8 | M&L for in repair / replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specifed and as directed by Engineer-in-Charge. |
| 9 | All as per Srl Item No 8 above but of size cross-sectional area 16.0 Sqmm, 4 -core. |
| 10 | All as per Srl Item No 8 above but of size cross-sectional area 25.0 Sqmm, 4 -core. |
| 11 | All as per Srl Item No 8 above but of size cross-sectional area 35.0 Sqmm, 3.5 -core. |
| 12 | All as per Srl Item No 8 above but of size cross-sectional area 50.0 Sqmm, 3.5 -core. |
| 13 | All as per Srl Item No 8 above but of size cross-sectional area 70.0 Sqmm, 3.5 -core. |
| 14 | All as per Srl Item No 8 above but of size cross-sectional area 95.0 Sqmm, 4 -core. |
| 15 | All as per Srl Item No 8 above but of size cross-sectional area 120.0 Sqmm, 3.5 -core. |
| 16 | S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm, complete all as specifed and as directed by Engineer-in-Charge. |
| 17 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting,200 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specifed and as directed by Engineer-in-Charge. |
| 18 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting,160 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. |
| 19 | S&F including taking down Multi Function Meter with Voltage, Ampere, Frequency and Power Factor with RS- 485 with wiring required at site, complete all as specifed and as directed by Engineer-in-Charge. |
| 20 | S&F including taking down Electrical Insulating Mat 2.5mm thick made out of Dielectric 'Elastomer' which possess elastic properties and may be natural or synthetic in nature. Should have Working Voltage - 1.1 KV, P Fire Retardant, fire self-extinguish within 5 Seconds of lighting, High Elongation & Tensile Strength. No tear or breakage due to Trolley movement & Foot Traffic, Resistant to Acids, Alkalis, Solvent and transformer Oil, Pasteable type can be easily pasted on Floor, Water and Moisture Proof, complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting,400 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. |
| 22 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting,630 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. |
| 23 | S&F including taking down On Load Change Over Switch 100 Amp capacity, 4 Pole, 415 Volt, 50 Hz, fitted in existing panel with selector switch, complete all as specified and as directed by Engineer-in-Charge. |
| 24 | All as per item No. 23 above but of capacity 200 Amp, as per existing size complete all as specifed and as directed by Engineer-in-Charge. |
| 25 | All as per item No. 23 above but of capacity 315 Amp, as per existing size complete all as specifed and as directed by Engineer-in-Charge. |
| 26 | All as per item No. 23 above but of capacity 400 Amp, as per existing size complete all as specifed and as directed by Engineer-in-Charge. |
| 27 | All as per item No. 23 above but of capacity 630 Amp, as per existing size complete all as specifed and as directed by Engineer-in-Charge. |
| 28 | S&F in repair Copper Bus Bar strip ,32x6 mm including fixing in panel making hole with all the sleeve and connecting arrengments complete all as specifed and as directed by Engineer-in-Charge. |
| 29 | Taking out of LT Air Circuit breaker of capacity 400 to 1000 Amps KV from the LT Panel and opening top cover, de-carbonizing moving and fixed contacts, lubricating, inspecting the tripping relay, tripping coil and checking for tripping system, meggaring all the contacts and fixing back the Air Circuit Breaker to LT Panel and testing complete all as specifed and as directed by Engineer-in-Charge. |
| 30 | S&F in repair for ACB 4 Pole, 415 V, Manual Drawout type WITH microprocessor release of capacity 630-800 amps Make : ( as per existing) complete all as specifed and as directed by Engineer-in-Charge. |
| 31 | Supply and fix in repair bus bar chambers with factory fabricated suitable for 3 Phase & neutral iron clad with 4 Nos 200 amp rated aluminium strips with two Nos Earthing connection bolt with locking arrangement front door operated complete making good the disturbed wall surfaces complete all as specifed and as directed by Engineer-in-Charge. |
| 32 | Supply, installation, testing and commissioning of electric LT Feeder Pillar Box of size 600 mmx600mm x300 mm (depth) , outdoor, cubical type, Pedestal mounted, factory made, CPRI approved,, Aluminium Bus Bar 400 Amps fabricated out of 3.15mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following Inccoming:- (a) MCCB, four pole, 250 Amps, 415 Volts, adjustable type, with breaking capacity 35 KA-02 nos |
| 33 | Supply, installation, testing and commissioning in replacement electric LT Feeder Pillar Box of size 600 mmx600mm x300 mm (depth), outdoor, cubical type, Pedestal mounted, factory made, CPRI approved,, Aluminium Bus Bar 400 Amps fabricated out of 3.15mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following Incoming:- (a) Change Over Switch 250 Amps -02 Nos (enclosed in panel) |
| 34 | S&F in repair aluminium lugs of different size specified below as directed for alumium cable complete all as specified by engineer in charge. |
| 35 | 16 Sqmm |
| 36 | 25 sqmm |
| 37 | 50 sqmm |
| 38 | 95 sqmm |
| 39 | 120 sqmm |
| 40 | 150 sqmm |
| 41 | 185 sqmm |
| 42 | 240 sqmm |
| 43 | 315 sqmm |
| 44 | Supply, installation, testing and commissioning in repalcement electric LT Feeder Pillar Box, outdoor,of size 1200x1000x450(depth) in mm cubical type, Pedestal mounted, factory made, CPRI approved,, Aluminium Bus Bar 400 Amps fabricated out of 3.15mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following Inccoming:- (a) Change Over Switch 250 Amps -02 Nos (b) MCCB, four pole, 250 Amps, 415 Volts, adjustable type, with breaking capacity 35 KA- 02 No ( incl 02Nos Amp meter).(c) MFn Meter V, A, F, kW, KVA, kVAr, kWh, , PF etc -01 Nos (e) Suitable Contacter, relay,& circuit protection device Outgoing (i) MCCB 4 pole 415 Volts TPN of capacity 250 amps thermal magnetic release adjustable type of breaking capacity 25 KA-03 No With addition to Amp meter-03(ii) MCCB 4 pole 415 Volts of capacity 160 amps thermal magnetic release adjustable type of breaking capacity 25 KA-03 Nos With addition to Amp meter-03 Please Enable Macros to View BoQ information |
| 45 | Supply, installation, testing and commissioning in repalcement electric LT Feeder Pillar Box, outdoor,of size 1200x1000x450(depth) in mm cubical type, Pedestal mounted, factory made, CPRI approved,, Aluminium Bus Bar 400 Amps fabricated out of 3.15mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following Inccoming:- (a) Change Over Switch 250 Amps -02 Nos (b) MCCB, four pole, 250 Amps, 415 Volts, adjustable type, with breaking capacity 35 KA- 02 No ( incl 02Nos Amp meter).(c) MFn Meter V, A, F, kW, KVA, kVAr, kWh, , PF etc -01 Nos (e) Suitable Contacter, relay,& circuit protection device Outgoing (i) MCCB 4 pole 415 Volts TPN of capacity 250 amps thermal magnetic release adjustable type of breaking capacity 25 KA-03 No With addition to Amp meter-03(ii) MCCB 4 pole 415 Volts of capacity 160 amps thermal magnetic release adjustable type of breaking capacity 25 KA-03 Nos With addition to Amp meter-03 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender