Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56940896

Tender For Comprehensive Maintenance Of Borewells And Tube Wells, Submersible Pump, Lt Panels And Misc Works At Sector B Under Ge (U) Ambala Cantt.

Issued by Statutory Bodies & Commissions/Committees · Ambala, Haryana
Tender Value
49 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
13 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance Of Borewells And Tube Wells, Submersible Pump, Lt Panels And Misc Works At Sector B Under Ge (U) Ambala Cantt.

BOQ

Name of Work:- Comprehensive maint of borewells and tube wells, submersible pump, LT panels and Misc works at Sector B under GE (U) Ambala Cantt.
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE UTILITY AMBALA CANTT NAME OF WORK : Comprehensive maint of borewells and tube wells, submersible pump, LT panels and Misc works at Sector \\"B\\" under GE (U) Ambala Cantt. Contract No: GE (U)/AMB/67/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Excavation in trenches not exc 1.50 metre wide not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as specified and directed.
3Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
4Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
5Taking down old UNSV DI pipe line of 150 mm dia size complete all as specified and directed.
6All as per Ser item No 4.00 here in before but of size 100/80 mm bore.
7Taking out pump set along with column pipe flanged 100 mm bore with 2 nos submersible cable from bore hole of tube well with the help of chain pulley block or tripod located in different location by dismantling nut bolts and rubber gaskets and lowering down the same by refixing nuts, bolts and rubber gaskets complete all as specified and directed.(i) Motor should be discconected from site with in 24 hrs from recd of complain.Note: (i) Contractor self arranged spare 01x submersible motor with pump ready before taking out existing pump set due to supply not failure. Rs. 3000/- per day will be recovered from contractor payment if fail supply.(ii) No extra amount will be paid of ready spare motor pump.
8Material and labour for opening the motor and taking out of burnt winding wire from submersible motor of capacity 50 HP 3 phase and rewinding motor with suitable size of PVC coated copper winding wire including replacement of burnt bushes complete all including insulation material and testing and commissiong complete all as specified and directed. Note: (i) The any electric fault occur during the running of the motor will be detected by the contractor rectification of the fault and rate are deemed to be included in the item. (ii) The motor burnt due to improper cable joint of submersible cable will be beared by the contractor. (iii) The motor burnt due to earth fault due to poor insulated winding will be beared by the contractor.(iv) The cost of 2nd time burnt of the motor due to phase loss, cable fault, or any reason as mention in Para (i) to (iii) will be beared by the contractor. (v) unserviceable parts will be paid separately.
9All as per Ser item No 7.00 here in before but of capacity 40 HP
10All as per Ser item No 7.00 here in before but of capacity 30 HP
11Material and labour for replacement of bearing bush for submersible motor cap 50 HP complete all as specified and directed.
12All as per Ser item No 10.00 here in before but sleeve
13All as per Ser item No 10.00 here in before but sealing kit
14All as per Ser item No 10.00 here in before but thrust bearing pad
15All as per Ser item No 10.00 here in before but thrust plate
16Material and labour for replacement of motor / pump coupling for submersible motor upto 50 HP complete all as specified and directed.
17Material and labour for replacement of water drain plug for pump cap 50 HP complete all as specified and directed.
18All as per Ser item No 16.00 here in before but sand guard
19All as per Ser item No 16.00 here in before but upper bearing housing
20All as per Ser item No 16.00 here in before but lower bearing housing
21All as per Ser item No 16.00 here in before but adopter piece
22All as per Ser item No 16.00 here in before but upper flange with stud
23All as per Ser item No 16.00 here in before but lower flange.
24All as per Ser item No 16.00 here in before but stage bowl CI
25All as per Ser item No 16.00 here in before but impellor
26All as per Ser item No 16.00 here in before but neck ring gun metel.
27All as per Ser item No 16.00 here in before but pump shaft.
28All as per Ser item No 16.00 here in before but bowl stud with nut.
29All as per Ser item No 16.00 here in before but bowl bush
30Material and labour for replacement of bearing bush for submersible motor cap 40 HP complete all as specified and directed.
31All as per Ser item No 29.00 here in before but sleeve
32All as per Ser item No 29.00 here in before but sealing kit
33All as per Ser item No 29.00 here in before but thrust bearing pad
34All as per Ser item No 29.00 here in before but thrust plate
35Material and labour for replacement of motor / pump coupling for submersible motor upto 40 HP complete all as specified and directed.
36Material and labour for replacement of water drain plug for pump cap 40 HP complete all as specified and directed.
37All as per Ser item No 35.00 here in before but sand guard
38All as per Ser item No 35.00 here in before but upper bearing housing
39All as per Ser item No 35.00 here in before but lower bearing housing
40All as per Ser item No 35.00 here in before but adopter piece
41All as per Ser item No 35.00 here in before but upper flange with stud
42All as per Ser item No 35.00 here in before but lower flange.
43All as per Ser item No 35.00 here in before but stage bowl CI
44All as per Ser item No 35.00 here in before but impellor
45All as per Ser item No 35.00 here in before but neck ring gun metel.
46All as per Ser item No 35.00 here in before but distance sleeve stainless steel.
47All as per Ser item No 35.00 here in before but pump shaft.
48All as per Ser item No 35.00 here in before but bowl stud with nut.
49All as per Ser item No 35.00 here in before but bowl bush
50Material and labour for replacement of bearing bush for submersible motor cap 30 HP complete all as specified and directed.
51All as per Ser item No 49.00 here in before but sleeve
52All as per Ser item No 49.00 here in before but sealing kit
53All as per Ser item No 49.00 here in before but thrust bearing pad
54All as per Ser item No 49.00 here in before but thrust plate
55Material and labour for replacement of motor / pump coupling for submersible motor upto 30 HP complete all as specified and directed.
56Material and labour for replacement of water drain plug for pump cap 30 HP complete all as specified and directed.
57All as per Ser item No 55.00 here in before but sand guard
58All as per Ser item No 55.00 here in before but upper bearing housing
59All as per Ser item No 55.00 here in before but lower bearing housing
60All as per Ser item No 55.00 here in before but adopter piece
61All as per Ser item No 55.00 here in before but upper flange with stud
62All as per Ser item No 55.00 here in before but lower flange.
63All as per Ser item No 55.00 here in before but stage bowl CI
64All as per Ser item No 55.00 here in before but impellor
65All as per Ser item No 55.00 here in before but neck ring gun metel.
66All as per Ser item No 55.00 here in before but distance sleeve stainless steel.
67All as per Ser item No 55.00 here in before but pump shaft.
68All as per Ser item No 55.00 here in before but bowl stud with nut.
69All as per Ser item No 55.00 here in before but bowl bush
70Material and labour for replacement of MS Bolts & Nut 5/8\\" x 2\\" for column pipe of submersible pump complete all as specified and directed.
71Material and labour for replacement of rubber gasket for 100 mm bore pipe complete all as specified and directed.
72Material and labour for replacement of PVC submersible copper cable flat of size 25 Sqmm 3 Core including tieing with column pipe with nylon rope complete all as specified and directed.
73All as per Ser item No 71.00 here in before but copper cable size 16 Sqmm
74Supply, lowering, jointing, against replacement of unserviceable GI pipe heavy duty 100mm internal dia 3 mtr long with both ends threaded and fitted with heavy duty MS flanges 14mm thick, two Nos groves for submersible cable continuous welded and drilled 4 Nos hole, complete as column pipe including jointing material such as bolts, nuts, washers and rubber gasket etc complete all as specified and directed.
75Material & labour for replacement of fully automatic citation star delta starter in sheet metal enclosure with citation M contactor and pneumatic timers suitable for upto 50 HP submersible motor complete with CTs , Digital Amp meter, voltmeter with selector switch ,LED indicator with electronic over load relay 5-60 amp contactor type E complete all as specified and directed.
76Material & labour for replacement of MCCB FP 400 Amp, 36KA breaking capacity, 415 V adjustable type complete all as specified and directed.
77All as per Ser item No 75.00 here in before but 250 Amp.
78All as per Ser item No 75.00 here in before but 200Amp
79All as per Ser item No 75.00 here in before but 160 Amp
80All as per Ser item No 75.00 here in before but MCCB TP/FP 125Amp 16KA breaking capacity
81Material & labour for replacement of MCCB TP/FP 63 Amp to 100Amp 16KA breaking capacity complete all as specified and directed.
82Smoothing and painting the wall (size 60x75cm) having backgound black in colour and written the technical data of motors/plants with white in colour complete all as specified and directed.
83Material & labour for CGI Sheets 14 SWG of size 2.5mx1mx15cm fitted with support of 20mm equal iron angle in box type with transparent acrylic white sheet on top of size 2mx1mx3mm thick written with computerised cut letters/diagram blue/red colours including LED light fittings 10W to 20W as per box size requirement including copper wiringof PVC Cable of size 1.5 sqmm with PVC conduit and complete all as specified and directed.
84Material & labour for replacement of high quality ACP sheet board/chart at installations of size 5 feet x 3 feet minimum with router cutting letter / chart / figure / diagram blue base of sheets and white colour acrylic letter/chart/figure/diagram with complete fitting complete all as specified and directed.Note: Details/description of printing material will be provided by department.
85Material and labour for Joint, channel, angle, tee, gate of pump house, motor base plate and sections, fixed independently with welding, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe-410W (GdeE-250) quality against worn out channel, angle iron etc complete all as specified and directed.
86Material & labour for replacement of Citation series contactors 70 Amp, 50HP, 3 Pole AC control, 415 V complete all as specified and directed.
87Material & labour for replacement of electronic overload relay with range 5.0 to 80 Amps 415 V, 50 Hz with including lugs and thimbles if required, complete all as specified and directed.
88Material & labour for rewinding of 1HP to 2 HP electric motor and pressure motor with fine enameled bared copper conductor of same gauge weight and turn along with insulating materials such as impregnated paper, cotton tap, varnish etc and keeping the rewinding in to the hot air oven till moisture evaporates and achieving proper insulation results and reassemble the motor including taking out old rewinding complete all as specified and directed for the following capacity. Note- Components/Parts shall be measured and paid separately.
89Supply only MS Impeller suitable for 1/2.5 HP monoblock pump set/pressure pump:-
90Impeller lock nut
91Sleeves
92Bearing bush
93Gasket
94Pump Shaft suitable for pump set including threading, machinery & lathe work complete.
95Bearings suitable for 1/2.5 HP motor (for drive end & dead end)
96Material & labour for attending any type pump/motor/LT panels/DGs/Starters complaint at pump houses and boosters and rectify the same, rates are also included for replcement of thimbles any type and any size with nut-bolts and cable jointing with insulating tape, gland packing, greasing in pumps/valves with all connected items complete all as specified and directed.Note: Complaint should be rectify within 02 Hrs otherwise a penalty of Rs. 250/- per day will be imposed.
97Material & labour for replacement of indoor/outdoor end termination cable jointing kit heat shrinkable type 1100 Volts grade, for XLPE/PVC cable of size upto 95 Sqmm complete all as specified and directed.
98Material & labour for LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and making electric connection with PVC insulated copper conductor (multistrand) cable of 1.5 sq mm size complete all as specified and directed.
99Material & Labour for Mild steel framed works such as grills, gratings etc with ends of bars, shouldered and/or rivetted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame works of water tank and similar work confirming to Fe.290.Gde-E-165 including nuts, bolts, washers, welding, binding, cold or hot, drilling holes for bolts, in any shape or size inclusive of one primer coat, one under coat and one finishing coat of paint including taking down existing complete all as specified and directed.
100Material & labour for replacement of old us base frame of centifugal pump set made out of angle iron of size, 50x50x6mm or medium channels of size MC-100 or as per existing including cutting, drilling hole or welding work required to make desired shape or existing size duly paint with one coat of primer red oxide and two coat of enamel paint complete all as specified and directed.Note: The base frame should be grouted complete in PCC foundation and should be taken necessary bearing strength before the installation of induction motor.
101Material & labour for replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 5m x 2m complete all as specified and directed.
102Material and labour for 15mm thick rendering on surface of any description of brick work, concrete surfaces in cement mortar 1:4 mixed with WPC @2% by weight of cement or as per manufacturer’s instructions, finished even and fair incl taking down existing plaster complete all as specified and directed. Note: WPC shall be measured and paid separately.
103Material and labour for 5 mm thick rough cast plaster over and including 10mm thick base rendering in cement mortar (1:4) mixed with WPC @2% by weight of cement or as per manufacturer’s instructions, finished even and fair incl taking down existing plaster complete all as specified and directed. Note : WPC shall be measured and paid separately.
104Material and labour for preparation of new wall surfaces and applying two coats of cement base paint over a one coat of cement primer complete all as specified and directed.
105Supply only integral water proofing compound complete all as specified and directed.
106Material and labour for 15mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and directed.
107Material and labour for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof incl dismantalling of existing sheeting of any type complete all as specified and directed.
108Material and labour for 415V 10KA 'B' curve miniature circuit breaker (MCB) TPN of 40/100 Amp poles and current carrying capacity in the DB complete with connection testing and commissioning including taking down old UNSV completed all as specified and directed.
109Material & labour for replacement of 0-50 Amp ammeter 3 phase ammeter Class 0.5 completed all as specified and directed.
110Material & labour for replacement of 0-500 Volts 3 phase Voltmeter Class 0.5 completed all as specified and directed.
111Material & labour for replacement of worn out / defective single phase preventor suitable upto 50 HP star- delta starter 415 V, 50 Hz, complete all as specified and directed.
112Material & labour for replacement of timer pneumatic type suitable upto 40/50 HP star- delta starter 415 V, 50 Hz complete all as specified and directed.
113Material & labour for replacement of sheet metal enclosure DB SPN 240 volts 8 way double door type with 200 amps rated bus bar for fixing MCB complete all as specified and directed.
114Material & labour for service wire 4.0 Sqmm PVC insulated and unsheathed FR, stranded copper conductor cable including taking down old UNSV complete all as specified and directed.
115All as per Ser item No 108.00 here in before but 2.5 Sqmm.
116Material & labour for replacement of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'B' curve complete all as specified and directed.
117Material & labour for replacement of MCB SPN 240 volts 32 Amps, 10 kA, 'C' curve complete all as specified and directed.
118Material and labour for Development of tube well with Air compressor of capacity 400 PSI and 1200 CFM till clear water is obtained including stabilization of the tube well and carrying out yield test indicating static water level, draw down, depth of bore upto 350 feet complete all as specified and directed. Note : Amount will be measure and paid rate per hrs.
119Material & labour for dismantling, opening & rewinding of 3 phase 415 volts monoblock pump set of capacity 2.5 to 3 HP with super enamelled copper winding wire as per existing gauge, cotton tape, leatherised strips, varnish, complete including testing after installation at site complete all as specified and directed.
120Material and labour for replacement of LT feeder pillar panel size 1.2M x 1.2M x 50cm with out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and rear openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction & misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves etc complete confirming to IS:8623/93 comprising of the following :-(a) TPN Aluminium bus bar 300 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long(b) Incoming MCCB 200 Amps 4 pole 415 Volts AC with thermal magnetic, adjustable type 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 02 No(c) Outgoing MCCB, 63 Amps, FP, 25 kA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, thermal based release for motor - 02 Nos (d) Starter 50HP with RYB indiacator, 3 Phase, AC, 50 Hz, complete - 01 Nos (e) Digital type Ammeter of Range 0 – 500 Amps with CTs & Selector Switch – 1 Set.(f) Digital type Voltmeter of Range 0 – 500 V with Selector Switch – 1 Nos.(g) Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
121Material and labour for repair of rusted & crack CI/DI water branch connection 150 to 300mm dia by using mechanical joint with connecting all accessories complete all as specified and directed. Note : (i) Cost of gasket and nut bolts ,washers' jointing of materials as required are inclusive in above job.(ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate.(iii) Excavation for pipe is included in job Work.
122Disconnection and removing the broken S/S spindle with checknut and Material and labour for brass spindle of same size and length along with checknut suitable for sluice valve 300 mm bore PN 1.6/PN1 of exisisting makes including threading machining and Lathe work complete along with fixing material such as gland packing nut and bolts complete all as specified and directed.
123All as per Ser item No 117.00 here in before but 200 mm bore.
124All as per Ser item No 117.00 here in before but 150 mm bore.
125All as per Ser item No 117.00 here in before but 100 mm bore.
126Material and labour for Centrifugally Cast (Spun) Ductile Iron Pressure Pipes of size 150mm bore with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and suitable for (push-on) rubber gasket incl taking down existing complete all as specified and directed.
127All as per Ser item No 121.00 here in before but of size 100 mm bore
128Material and labour for replacement cast iron fitting or ductile iron for spigot and socket /fanged pipe such as bends (any type radius and angle) tapers any type ( straight, bends, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross collers, caps and plugs upto 300 mm bore complete all as specified and directed.
129Material and labour for replacement of Cast iron sluice valve 150 mm dia, flanged ends, stem (spindle) of SS (forged) and check nut of gun Metal, PN rating 1.6, working parts conforming to IS :14846, and flanged ends having drilling as per IS:1538 including taking down old unserviceable sluice valve complete all as specified and directed.
130All as per Ser item No 124.00 here in before but 100 mm bore
131Material and labour for cast iron Non return valve 150mm nominal bore ISI marked conforming to IS-5312 including rubber/fiber board gasket, nuts, washers etc including taking down old unserviceable Non return valve (flanged) reflux complete all as specified and directed.
132All as per Ser item No 126.00 here in before but 100 mm bore
133Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) or under the over head tank/road cutting etc complete all as specified and directed.
134Material and labour for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and directed.
135Material and labour for PCC 1:3:6 type C-1 100mm thickness (using 20 mm graded mechanically crushed stone aggregate) as in plinth protection/PCC path, under over head tank & foundation of motor/header finished the surface even and smooth without using extra cement, joint filled with bitumen and sand mixture applied hot (area not exceeding 1.20 sqm ) complete all as specified and directed.
136Material and labour for replacement of Cast Iron water butterfly valve 80/100 mm dia flanged manual type and nut bolts and necessay parts, including taking down old unserviceable cast iron water butter fly valve complete all as specified and directed.
137Material and labour for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in path, paving etc finished even and smooth using extra cement complete all as specified and directed.
138Material and labour for rerplacement of Factory made, machine pressed pre-cast concrete, Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & no pigment set and jointed over 25 mm thick dry sand bedding as in floors cushioning layer below interlocking paver blocks watering and consolidation complete and pavings of selected shape and size as approved by GE conforming to (IS:15658-2006) complete all as specified and directed.
139Material and labour for Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thickwalls built in cement mortar 1 :4 complete all as specified and directed.
140Factory made, machine pressed pre-cast concrete, interlocking paver block with grey cement & no pigment set and jointed over and including 25 mm thick dry sand bedding as in floors cushioning layer below interlocking paver blocks including watering and consolidation complete and pavings of selected shape and size as approved by GE conforming to (IS:15658-2006) of 60 mm thick, M-30 grade complete all as specified and directed.
141Material and labour for Foot valve with flanged ends of size 100 mm with nut-bolts and rubber gasket suitable for pipe including taking out the unserviceable foot valve from the pipe complete all as specified and directed.
142Material and labour for brick masonary valve pit of size 1200 x 1200 x 12000mm dimensions, one brick thick valve pit of following internal dimension with two nos. of RCC slab cover of siutable size with handle to lift atleast 75mm thick having provision of valve key slot, earth work and PCC in foundation (1:3:6) Type C2 using 40mm graded stone aggregete 150 mm thick, PCC in coping on top (1:2:4),Type B1 using 20mm graded stone agregate 100mm thick including rendering 15mm thick and two coat of white wash on exposed surfaces on external wall above ground level incl demolition of old unserviceable existing complete all as specified and directed.Note: RCC slab rate are inclusive in the rates of valve pit with approved reinforcement and form work etc.
143Material and labour for scraping the existing paint by using wire brushes and sand paper etc and preparing the external surface and applying two coats of cement base paint on UG sump at babyal booster Qty-02, Harding line booster Qty -01,CWL booster Qty-01 complete all as specified and directed.
144Preparation of old surfaces of CI/DI/GI pipe 100 to 350 mm bore and applying one coat of synthetic enamel paint on all external surfaces of CI/DI pipe for rising supply, overflow and washout 100mm bore vertical length including necessary scaffolding and other arrangement required for painting complete all as specified and directed.
145Preparation of old surfaces of each pump set at booster and connected CI/DI/MS pipe and applying one coat of synthetic enamel blue paint on each pump set and connected CI/DI/MS pipe upto 150mm bore to the horijontal length complete all as specified and directed.
146Cutting/removing of bushes/small trees/vegetation growth upto a distance of appx 50 mtr around the UG sump,OHT,Pump house not exc 30cms deep incl drains all around the plant incl rough surface leveling/cutting,filling upto 12\\" height/ depth all around the plant and burning at a distance of 50mtr (minimum) in the presence of Engr-in-charge including sprinkling the round up chemicals for drying/killing the bushes,shrubs etc complete all as specified and directed.
147Material and labour for replacement of on load change over of 200 A, 415 V 3Phase and neutral with enclosure complete all as specified and directed.
148Material and labour for replacement of on load change over of 400 A,415 V ,3 Phase and neutral with enclosure complete all as specified and directed.
149Material and labour for replacement of DOL starter 415 volt 3 phase suitable for 05/7.5 HP motor complete all as specified and directed.
150Material and labour for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified and directed.Note: For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I.
151Material and labour for providing brick for cable cover of size 230mmx115mmx75mm laid in perpendicular to the cable abutting each other complete all as specified and directed.
152Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 95 Sqmm 3.5 Core including taking down existing complete all as specified and directed.
153All as per Ser item No 147.00 here in before but 70 Sqmm.
154All as per Ser item No 147.00 here in before but 50 Sqmm.
155Material and labour for replacement of first aid box at E/M installation to keep the first aid items i.e. Regular use medicine a tube of burnol, bandage one small snizer, banded etc, the box will be made out of GI sheet of 18 Gauge and the size of the box will be 30cm x 25 cm x 20 cm with openable window at front side with help of hinge at one side and locking arrangement at another side, openable window must painted with ''FIRST AID'' with red paint and whole box will fixed on wall at height not less then 2 mtr, complete all as specified and directed.
156Material and labour for seven stage cleaning and sterlization of inside OHT reservoir capacity 10000 Glns through bacterioligical treatment by using TERBAC G5, TERBAC-G-65 and ULTRA VOILET Ray, Make : Rays cleantech or equivalent.Process of seven stager are as under :-1. First stage is to draing out the water by using exist valve or high capacity dewatering system.2.Second stage is cleaning all the algae formation inside the tank by using TERBAC G10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.3. Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSI.4. Fourth stage and first bacteria screening is decertification by using TERBAC-G5 a Govt Laboratory certified brannded halogen compound.5. Fifth stage is cleaning the floor of water tank by heavy duty industrial vaccum cleaner.6. Sixth stage is the secord bacteria screening and sterilizing method by using ultra voilet ray ejector covering 360 degree within the tank and kills all suspended bacteria.7. Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65.Note : Company will submit govermnet laboratory test certificate of TERBAC-G5, TERBAC-G65, Fix the sticker mentioning the date of cleaning and name of site and also provide certificate confirming the completion of steriliztion of water tanks metnioning the name of station and date of cleaning.
157Material and labour for cleaning and washing underground sump reservoir of capacity upto 10000 gallon, disconnecting the inlet and outlet valves, cleaning the tank by blocking the water supply system including removing sludge/scale/sedements etc from bed level and scrapping the floor and wall surfaces with wire brush and cleaning with potassium permangnate (KMNO4) solution at least three times to remove oily surfaces from internal floor and wall of the tank and finally cleaning with fresh water and applying cement wash on walls including re-fxing of inlet and outlet valves and normalizing the water supply by opening valves after allowing suffcient drying time, including writing date of cleaning with synthetic enamel paint as \\"CLEANDED ON\\" complete all as specified and as directed Note: Quoted rate shall deemed to be inclusive of cost of Potassium permangnate, scaffolding (if required) and disposal of sludge/scale/sediments upto a distance of n.exc 50m from work site
158Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm, 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost.
159Note:- Amount of credit of Rs. 227170.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in PDF form which will be deducted offline while acceptance of tender. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56940896
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Maintenance Of Borewells And Tube Wells, Submersible Pump, Lt Panels And Misc Works At Sector B Under Ge (U) Ambala Cantt.
Basic Detail
Tender No CA NO GE U AMB 67 OF 2026-27
Bidding Type Tender
Location
City Ambala
State Haryana
Key Dates
Publish Date 10 Aug 2026
Submission Date 31 Aug 2026
Open Date 02 Sep 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Not Available
Document List
97b897f0-6aee-4fba-a06c-2318458a26cf.html
BOQ_878143.xls
Tender.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

97b897f0-6aee-4fba-a06c-2318458a26cf.html

xls

BOQ_878143.xls

pdf

Tender.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender